Web-based on mobile phone for automatic classification of power quality disturbance using the S-transform and support vector machines

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Analyzing power quality data manually requires a lot of time and special expertise. In this paper, a new approach is shown for automatic identification power quality disturbance on mobile phone by combining the S-transform, a support vector machine (SVM), wireless markup language (WML) and the Matlab web server (MWS). The S-transform is used to generate a set of features for the SVM to classify various power quality disturbances; while the WML and MWS are used to integrate the graphical and computational process through the mobile phone. Results obtained proved the robustness and effectiveness of the proposed method.

Original languageEnglish
Title of host publicationIEEE Region 10 Annual International Conference, Proceedings/TENCON
Pages1432-1437
Number of pages6
DOIs
Publication statusPublished - 2010
Event2010 IEEE Region 10 Conference, TENCON 2010 - Fukuoka
Duration: 21 Nov 201024 Nov 2010

Other

Other2010 IEEE Region 10 Conference, TENCON 2010
CityFukuoka
Period21/11/1024/11/10

Fingerprint

Power quality
Mobile phones
Support vector machines
Markup languages
Mathematical transformations
Servers

Keywords

  • Matlab web server
  • Power quality
  • S-Transform
  • Support vector machine
  • Wireless markup language

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Computer Science Applications

Cite this

Web-based on mobile phone for automatic classification of power quality disturbance using the S-transform and support vector machines. / Wenda, Alex; Hussain, Aini; Abdul Samad, Salina; Mohamed, Ramizi; M A, Hannan.

IEEE Region 10 Annual International Conference, Proceedings/TENCON. 2010. p. 1432-1437 5686118.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Wenda, A, Hussain, A, Abdul Samad, S, Mohamed, R & M A, H 2010, Web-based on mobile phone for automatic classification of power quality disturbance using the S-transform and support vector machines. in IEEE Region 10 Annual International Conference, Proceedings/TENCON., 5686118, pp. 1432-1437, 2010 IEEE Region 10 Conference, TENCON 2010, Fukuoka, 21/11/10. https://doi.org/10.1109/TENCON.2010.5686118
@inproceedings{f1fab516d4d443baaf8b6187b021a5dc,
title = "Web-based on mobile phone for automatic classification of power quality disturbance using the S-transform and support vector machines",
abstract = "Analyzing power quality data manually requires a lot of time and special expertise. In this paper, a new approach is shown for automatic identification power quality disturbance on mobile phone by combining the S-transform, a support vector machine (SVM), wireless markup language (WML) and the Matlab web server (MWS). The S-transform is used to generate a set of features for the SVM to classify various power quality disturbances; while the WML and MWS are used to integrate the graphical and computational process through the mobile phone. Results obtained proved the robustness and effectiveness of the proposed method.",
keywords = "Matlab web server, Power quality, S-Transform, Support vector machine, Wireless markup language",
author = "Alex Wenda and Aini Hussain and {Abdul Samad}, Salina and Ramizi Mohamed and {M A}, Hannan",
year = "2010",
doi = "10.1109/TENCON.2010.5686118",
language = "English",
isbn = "9781424468904",
pages = "1432--1437",
booktitle = "IEEE Region 10 Annual International Conference, Proceedings/TENCON",

}

TY - GEN

T1 - Web-based on mobile phone for automatic classification of power quality disturbance using the S-transform and support vector machines

AU - Wenda, Alex

AU - Hussain, Aini

AU - Abdul Samad, Salina

AU - Mohamed, Ramizi

AU - M A, Hannan

PY - 2010

Y1 - 2010

N2 - Analyzing power quality data manually requires a lot of time and special expertise. In this paper, a new approach is shown for automatic identification power quality disturbance on mobile phone by combining the S-transform, a support vector machine (SVM), wireless markup language (WML) and the Matlab web server (MWS). The S-transform is used to generate a set of features for the SVM to classify various power quality disturbances; while the WML and MWS are used to integrate the graphical and computational process through the mobile phone. Results obtained proved the robustness and effectiveness of the proposed method.

AB - Analyzing power quality data manually requires a lot of time and special expertise. In this paper, a new approach is shown for automatic identification power quality disturbance on mobile phone by combining the S-transform, a support vector machine (SVM), wireless markup language (WML) and the Matlab web server (MWS). The S-transform is used to generate a set of features for the SVM to classify various power quality disturbances; while the WML and MWS are used to integrate the graphical and computational process through the mobile phone. Results obtained proved the robustness and effectiveness of the proposed method.

KW - Matlab web server

KW - Power quality

KW - S-Transform

KW - Support vector machine

KW - Wireless markup language

UR - http://www.scopus.com/inward/record.url?scp=79951626170&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951626170&partnerID=8YFLogxK

U2 - 10.1109/TENCON.2010.5686118

DO - 10.1109/TENCON.2010.5686118

M3 - Conference contribution

SN - 9781424468904

SP - 1432

EP - 1437

BT - IEEE Region 10 Annual International Conference, Proceedings/TENCON

ER -