Abstract

The effects of various types of stiffeners on the connection behaviour between box-column to I-beams has been studied both experimentally and analytically using the finite element method. The external T-stiffener has been found to provide the most suitable form of stiffening in terms of stiffness, strength, ductility and ease in fabrication which are the basic criteria for a good moment connection. A simple design method to determine the dimensions of the external T-stiffener for both the two-wat and four-way connections has been proposed. A method for predicting the moment-rotation characteristic of the connection using a least-square curve-fitting procedure is also described. Finally, two four-way full-scale specimens designed in accordance with the design guidelines were tested to failure. The experimental results as well as results from finite element analysis show the validity of both the design guidelines and the proposed moment-rotation functions.

Original languageEnglish
Pages (from-to)77-98
Number of pages22
JournalJournal of Constructional Steel Research
Volume26
Issue number2-3
DOIs
Publication statusPublished - 1993
Externally publishedYes

Fingerprint

Finite element method
Curve fitting
Ductility
Stiffness
Fabrication

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Materials Science(all)

Cite this

Use of external T-stiffeners in box-column to I-beam connections. / Lee, S. L.; Ting, L. C.; Shanmugam, N. E.

In: Journal of Constructional Steel Research, Vol. 26, No. 2-3, 1993, p. 77-98.

Research output: Contribution to journalArticle

Lee, S. L. ; Ting, L. C. ; Shanmugam, N. E. / Use of external T-stiffeners in box-column to I-beam connections. In: Journal of Constructional Steel Research. 1993 ; Vol. 26, No. 2-3. pp. 77-98.
@article{93377d6e387c4f7ab9376ec337e729e9,
title = "Use of external T-stiffeners in box-column to I-beam connections",
abstract = "The effects of various types of stiffeners on the connection behaviour between box-column to I-beams has been studied both experimentally and analytically using the finite element method. The external T-stiffener has been found to provide the most suitable form of stiffening in terms of stiffness, strength, ductility and ease in fabrication which are the basic criteria for a good moment connection. A simple design method to determine the dimensions of the external T-stiffener for both the two-wat and four-way connections has been proposed. A method for predicting the moment-rotation characteristic of the connection using a least-square curve-fitting procedure is also described. Finally, two four-way full-scale specimens designed in accordance with the design guidelines were tested to failure. The experimental results as well as results from finite element analysis show the validity of both the design guidelines and the proposed moment-rotation functions.",
author = "Lee, {S. L.} and Ting, {L. C.} and Shanmugam, {N. E.}",
year = "1993",
doi = "10.1016/0143-974X(93)90030-V",
language = "English",
volume = "26",
pages = "77--98",
journal = "Journal of Constructional Steel Research",
issn = "0143-974X",
publisher = "Elsevier BV",
number = "2-3",

}

TY - JOUR

T1 - Use of external T-stiffeners in box-column to I-beam connections

AU - Lee, S. L.

AU - Ting, L. C.

AU - Shanmugam, N. E.

PY - 1993

Y1 - 1993

N2 - The effects of various types of stiffeners on the connection behaviour between box-column to I-beams has been studied both experimentally and analytically using the finite element method. The external T-stiffener has been found to provide the most suitable form of stiffening in terms of stiffness, strength, ductility and ease in fabrication which are the basic criteria for a good moment connection. A simple design method to determine the dimensions of the external T-stiffener for both the two-wat and four-way connections has been proposed. A method for predicting the moment-rotation characteristic of the connection using a least-square curve-fitting procedure is also described. Finally, two four-way full-scale specimens designed in accordance with the design guidelines were tested to failure. The experimental results as well as results from finite element analysis show the validity of both the design guidelines and the proposed moment-rotation functions.

AB - The effects of various types of stiffeners on the connection behaviour between box-column to I-beams has been studied both experimentally and analytically using the finite element method. The external T-stiffener has been found to provide the most suitable form of stiffening in terms of stiffness, strength, ductility and ease in fabrication which are the basic criteria for a good moment connection. A simple design method to determine the dimensions of the external T-stiffener for both the two-wat and four-way connections has been proposed. A method for predicting the moment-rotation characteristic of the connection using a least-square curve-fitting procedure is also described. Finally, two four-way full-scale specimens designed in accordance with the design guidelines were tested to failure. The experimental results as well as results from finite element analysis show the validity of both the design guidelines and the proposed moment-rotation functions.

UR - http://www.scopus.com/inward/record.url?scp=0027316581&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027316581&partnerID=8YFLogxK

U2 - 10.1016/0143-974X(93)90030-V

DO - 10.1016/0143-974X(93)90030-V

M3 - Article

VL - 26

SP - 77

EP - 98

JO - Journal of Constructional Steel Research

JF - Journal of Constructional Steel Research

SN - 0143-974X

IS - 2-3

ER -