Thermal comfort assessment: A case study at Malaysian automotive industry

A. R. Ismail, N. Jusoh, Rozli Zulkifli, Kamaruzzaman Sopian, Baba Md Deros

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Problem statement: Thermal comfort has a great influence on the productivity and satisfaction of indoor building occupants. The exposure to excessive heat during work may cause discomfort and contributed to low productivity among workers. Malaysia known with its hot and humid weather where in most of the survey study published indicated that workers in Malaysia automotive industries had exposed to excessive temperature while working. The study investigated the thermal comfort level experienced by workers at Malaysian automotive industry. Approach: The study had been conducted at one automotive parts assembly factory in Malaysia. The human subjects for the study constitute operators at tire receiving section of the factory. The environment examined was the relative humidity (%), WBGT, air temperature and radiant temperature (°C) of the surrounding workstation area. The environmental factors were measured using Babuc apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then thermal comfort of the workers was assessed by using ASHRAE thermal sensation scale by using Predicted Mean Vote (PMV). Further Predicted Percentage Dissatisfied (PPD) was used to estimate the thermal comfort satisfaction of the occupant. Finally the PPD versus PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. Results: The trend of relative humidity curve from the graph also indicated the increasing level of discomfort. The radiant temperature observed seems consistent during the study while there was decreasing of WBGT start from afternoon due to the rain. The study revealed that the PPD value of 54% of the workers population at the workstation are likely to be satisfied with thermal comfort at this station while the PMV index from ASHRAE indicated the value 1.07-1.41. Conclusion: The empirical study from the PPD and PMV index indicated that workers working at this were influenced by the heat. The less of PPD value from 80% of the population satisfied with the thermal comfort showed the environment factors that were not good for worker while the PMV index showed the area of work is slightly warm.

Original languageEnglish
Pages (from-to)1495-1501
Number of pages7
JournalAmerican Journal of Applied Sciences
Volume6
Issue number8
DOIs
Publication statusPublished - 2009

Fingerprint

Thermal comfort
Automotive industry
Industrial plants
Atmospheric humidity
Productivity
Temperature
Tires
Rain
Time series
Air
Hot Temperature

Keywords

  • Predicted mean vote
  • Predicted percentage dissatisfied
  • Temperature
  • Thermal comfort

ASJC Scopus subject areas

  • General

Cite this

Thermal comfort assessment : A case study at Malaysian automotive industry. / Ismail, A. R.; Jusoh, N.; Zulkifli, Rozli; Sopian, Kamaruzzaman; Md Deros, Baba.

In: American Journal of Applied Sciences, Vol. 6, No. 8, 2009, p. 1495-1501.

Research output: Contribution to journalArticle

@article{6d81e328fadd495ba730a56eaa91a85a,
title = "Thermal comfort assessment: A case study at Malaysian automotive industry",
abstract = "Problem statement: Thermal comfort has a great influence on the productivity and satisfaction of indoor building occupants. The exposure to excessive heat during work may cause discomfort and contributed to low productivity among workers. Malaysia known with its hot and humid weather where in most of the survey study published indicated that workers in Malaysia automotive industries had exposed to excessive temperature while working. The study investigated the thermal comfort level experienced by workers at Malaysian automotive industry. Approach: The study had been conducted at one automotive parts assembly factory in Malaysia. The human subjects for the study constitute operators at tire receiving section of the factory. The environment examined was the relative humidity ({\%}), WBGT, air temperature and radiant temperature (°C) of the surrounding workstation area. The environmental factors were measured using Babuc apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then thermal comfort of the workers was assessed by using ASHRAE thermal sensation scale by using Predicted Mean Vote (PMV). Further Predicted Percentage Dissatisfied (PPD) was used to estimate the thermal comfort satisfaction of the occupant. Finally the PPD versus PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. Results: The trend of relative humidity curve from the graph also indicated the increasing level of discomfort. The radiant temperature observed seems consistent during the study while there was decreasing of WBGT start from afternoon due to the rain. The study revealed that the PPD value of 54{\%} of the workers population at the workstation are likely to be satisfied with thermal comfort at this station while the PMV index from ASHRAE indicated the value 1.07-1.41. Conclusion: The empirical study from the PPD and PMV index indicated that workers working at this were influenced by the heat. The less of PPD value from 80{\%} of the population satisfied with the thermal comfort showed the environment factors that were not good for worker while the PMV index showed the area of work is slightly warm.",
keywords = "Predicted mean vote, Predicted percentage dissatisfied, Temperature, Thermal comfort",
author = "Ismail, {A. R.} and N. Jusoh and Rozli Zulkifli and Kamaruzzaman Sopian and {Md Deros}, Baba",
year = "2009",
doi = "10.3844/ajassp.2009.1495.1501",
language = "English",
volume = "6",
pages = "1495--1501",
journal = "American Journal of Applied Sciences",
issn = "1546-9239",
publisher = "Science Publications",
number = "8",

}

TY - JOUR

T1 - Thermal comfort assessment

T2 - A case study at Malaysian automotive industry

AU - Ismail, A. R.

AU - Jusoh, N.

AU - Zulkifli, Rozli

AU - Sopian, Kamaruzzaman

AU - Md Deros, Baba

PY - 2009

Y1 - 2009

N2 - Problem statement: Thermal comfort has a great influence on the productivity and satisfaction of indoor building occupants. The exposure to excessive heat during work may cause discomfort and contributed to low productivity among workers. Malaysia known with its hot and humid weather where in most of the survey study published indicated that workers in Malaysia automotive industries had exposed to excessive temperature while working. The study investigated the thermal comfort level experienced by workers at Malaysian automotive industry. Approach: The study had been conducted at one automotive parts assembly factory in Malaysia. The human subjects for the study constitute operators at tire receiving section of the factory. The environment examined was the relative humidity (%), WBGT, air temperature and radiant temperature (°C) of the surrounding workstation area. The environmental factors were measured using Babuc apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then thermal comfort of the workers was assessed by using ASHRAE thermal sensation scale by using Predicted Mean Vote (PMV). Further Predicted Percentage Dissatisfied (PPD) was used to estimate the thermal comfort satisfaction of the occupant. Finally the PPD versus PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. Results: The trend of relative humidity curve from the graph also indicated the increasing level of discomfort. The radiant temperature observed seems consistent during the study while there was decreasing of WBGT start from afternoon due to the rain. The study revealed that the PPD value of 54% of the workers population at the workstation are likely to be satisfied with thermal comfort at this station while the PMV index from ASHRAE indicated the value 1.07-1.41. Conclusion: The empirical study from the PPD and PMV index indicated that workers working at this were influenced by the heat. The less of PPD value from 80% of the population satisfied with the thermal comfort showed the environment factors that were not good for worker while the PMV index showed the area of work is slightly warm.

AB - Problem statement: Thermal comfort has a great influence on the productivity and satisfaction of indoor building occupants. The exposure to excessive heat during work may cause discomfort and contributed to low productivity among workers. Malaysia known with its hot and humid weather where in most of the survey study published indicated that workers in Malaysia automotive industries had exposed to excessive temperature while working. The study investigated the thermal comfort level experienced by workers at Malaysian automotive industry. Approach: The study had been conducted at one automotive parts assembly factory in Malaysia. The human subjects for the study constitute operators at tire receiving section of the factory. The environment examined was the relative humidity (%), WBGT, air temperature and radiant temperature (°C) of the surrounding workstation area. The environmental factors were measured using Babuc apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then thermal comfort of the workers was assessed by using ASHRAE thermal sensation scale by using Predicted Mean Vote (PMV). Further Predicted Percentage Dissatisfied (PPD) was used to estimate the thermal comfort satisfaction of the occupant. Finally the PPD versus PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. Results: The trend of relative humidity curve from the graph also indicated the increasing level of discomfort. The radiant temperature observed seems consistent during the study while there was decreasing of WBGT start from afternoon due to the rain. The study revealed that the PPD value of 54% of the workers population at the workstation are likely to be satisfied with thermal comfort at this station while the PMV index from ASHRAE indicated the value 1.07-1.41. Conclusion: The empirical study from the PPD and PMV index indicated that workers working at this were influenced by the heat. The less of PPD value from 80% of the population satisfied with the thermal comfort showed the environment factors that were not good for worker while the PMV index showed the area of work is slightly warm.

KW - Predicted mean vote

KW - Predicted percentage dissatisfied

KW - Temperature

KW - Thermal comfort

UR - http://www.scopus.com/inward/record.url?scp=77950998262&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950998262&partnerID=8YFLogxK

U2 - 10.3844/ajassp.2009.1495.1501

DO - 10.3844/ajassp.2009.1495.1501

M3 - Article

AN - SCOPUS:77950998262

VL - 6

SP - 1495

EP - 1501

JO - American Journal of Applied Sciences

JF - American Journal of Applied Sciences

SN - 1546-9239

IS - 8

ER -