The influences of connectors and adaptors to Fiber-To-The-Home network performance

Mohd Syuhaimi Ab Rahman, Mastang, Kasmiran Jumari

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Problem statement: The reliability of the entire communications network was dependent on the reliability of each single element. Connector was important devices that can affect the performance of the fiber communication. There were a large number of issues that affect the performance of fiber optic connectors in today's networks. These factors were increasingly as data rates, the number of wavelengths and transmission distances continue to escalate. Approach: Therefore this study was carried out to test on the influence of connectors and adapters to the performance of the optical network. Initially the actual attenuation of connector and adaptor were tested by using multifunction loss tester. The first two 1 m corning optical fibers with a connector at each end are measured. Then, both the 1 m corning optical fibers were joined together by an adaptor and connected to the Multifunction loss tester. Three types of wavelength are used as the source to test the attenuation of the fiber which is 1310, 1490-1550 nm. In order to measure the Bit Error Rate (BER) and the power loss in optical fiber communication, a simple simulation was carried out by using software opti sys. Results: The attenuation on the connector was caused mainly by existence of impurities in the connector, less perfect connection, scattering of beam and others. These causes the parameter such as power received, Q-factor, minimum BER and also the eye-height to change. Changes in these parameters also affect the performance at the user end. It was very critical that causes of attenuation to be eliminated. Conclusion/Recommendations: From the result it can be concluded that, the greater the attenuation, the greater the decrease in power received. It also affects the Q-factor of the system where as the attenuation increase, the maximum Q-factor decreases. As for the minimum BER, minimum BER changes as the attenuation increase initially, after a maximum value it decreases as the attenuation increases.

Original languageEnglish
Pages (from-to)186-195
Number of pages10
JournalAmerican Journal of Applied Sciences
Volume9
Issue number2
Publication statusPublished - 2012

Fingerprint

Home networks
Network performance
Bit error rate
Optical fibers
Optical fiber communication
Wavelength
Fibers
Fiber optic networks
Fiber optics
Telecommunication networks
Scattering
Impurities
Fiber to the x
Communication

Keywords

  • Adaptor effect
  • Attenuation increase
  • Caused mainly
  • Connector attenuation
  • Connector effect
  • Connector reliability
  • Maximum value
  • Optical energy
  • Q-factor decrease
  • Scattering attenuation

ASJC Scopus subject areas

  • General

Cite this

The influences of connectors and adaptors to Fiber-To-The-Home network performance. / Ab Rahman, Mohd Syuhaimi; Mastang; Jumari, Kasmiran.

In: American Journal of Applied Sciences, Vol. 9, No. 2, 2012, p. 186-195.

Research output: Contribution to journalArticle

@article{b3ec8afb1a30458b958e9f1ded8ae555,
title = "The influences of connectors and adaptors to Fiber-To-The-Home network performance",
abstract = "Problem statement: The reliability of the entire communications network was dependent on the reliability of each single element. Connector was important devices that can affect the performance of the fiber communication. There were a large number of issues that affect the performance of fiber optic connectors in today's networks. These factors were increasingly as data rates, the number of wavelengths and transmission distances continue to escalate. Approach: Therefore this study was carried out to test on the influence of connectors and adapters to the performance of the optical network. Initially the actual attenuation of connector and adaptor were tested by using multifunction loss tester. The first two 1 m corning optical fibers with a connector at each end are measured. Then, both the 1 m corning optical fibers were joined together by an adaptor and connected to the Multifunction loss tester. Three types of wavelength are used as the source to test the attenuation of the fiber which is 1310, 1490-1550 nm. In order to measure the Bit Error Rate (BER) and the power loss in optical fiber communication, a simple simulation was carried out by using software opti sys. Results: The attenuation on the connector was caused mainly by existence of impurities in the connector, less perfect connection, scattering of beam and others. These causes the parameter such as power received, Q-factor, minimum BER and also the eye-height to change. Changes in these parameters also affect the performance at the user end. It was very critical that causes of attenuation to be eliminated. Conclusion/Recommendations: From the result it can be concluded that, the greater the attenuation, the greater the decrease in power received. It also affects the Q-factor of the system where as the attenuation increase, the maximum Q-factor decreases. As for the minimum BER, minimum BER changes as the attenuation increase initially, after a maximum value it decreases as the attenuation increases.",
keywords = "Adaptor effect, Attenuation increase, Caused mainly, Connector attenuation, Connector effect, Connector reliability, Maximum value, Optical energy, Q-factor decrease, Scattering attenuation",
author = "{Ab Rahman}, {Mohd Syuhaimi} and Mastang and Kasmiran Jumari",
year = "2012",
language = "English",
volume = "9",
pages = "186--195",
journal = "American Journal of Applied Sciences",
issn = "1546-9239",
publisher = "Science Publications",
number = "2",

}

TY - JOUR

T1 - The influences of connectors and adaptors to Fiber-To-The-Home network performance

AU - Ab Rahman, Mohd Syuhaimi

AU - Mastang,

AU - Jumari, Kasmiran

PY - 2012

Y1 - 2012

N2 - Problem statement: The reliability of the entire communications network was dependent on the reliability of each single element. Connector was important devices that can affect the performance of the fiber communication. There were a large number of issues that affect the performance of fiber optic connectors in today's networks. These factors were increasingly as data rates, the number of wavelengths and transmission distances continue to escalate. Approach: Therefore this study was carried out to test on the influence of connectors and adapters to the performance of the optical network. Initially the actual attenuation of connector and adaptor were tested by using multifunction loss tester. The first two 1 m corning optical fibers with a connector at each end are measured. Then, both the 1 m corning optical fibers were joined together by an adaptor and connected to the Multifunction loss tester. Three types of wavelength are used as the source to test the attenuation of the fiber which is 1310, 1490-1550 nm. In order to measure the Bit Error Rate (BER) and the power loss in optical fiber communication, a simple simulation was carried out by using software opti sys. Results: The attenuation on the connector was caused mainly by existence of impurities in the connector, less perfect connection, scattering of beam and others. These causes the parameter such as power received, Q-factor, minimum BER and also the eye-height to change. Changes in these parameters also affect the performance at the user end. It was very critical that causes of attenuation to be eliminated. Conclusion/Recommendations: From the result it can be concluded that, the greater the attenuation, the greater the decrease in power received. It also affects the Q-factor of the system where as the attenuation increase, the maximum Q-factor decreases. As for the minimum BER, minimum BER changes as the attenuation increase initially, after a maximum value it decreases as the attenuation increases.

AB - Problem statement: The reliability of the entire communications network was dependent on the reliability of each single element. Connector was important devices that can affect the performance of the fiber communication. There were a large number of issues that affect the performance of fiber optic connectors in today's networks. These factors were increasingly as data rates, the number of wavelengths and transmission distances continue to escalate. Approach: Therefore this study was carried out to test on the influence of connectors and adapters to the performance of the optical network. Initially the actual attenuation of connector and adaptor were tested by using multifunction loss tester. The first two 1 m corning optical fibers with a connector at each end are measured. Then, both the 1 m corning optical fibers were joined together by an adaptor and connected to the Multifunction loss tester. Three types of wavelength are used as the source to test the attenuation of the fiber which is 1310, 1490-1550 nm. In order to measure the Bit Error Rate (BER) and the power loss in optical fiber communication, a simple simulation was carried out by using software opti sys. Results: The attenuation on the connector was caused mainly by existence of impurities in the connector, less perfect connection, scattering of beam and others. These causes the parameter such as power received, Q-factor, minimum BER and also the eye-height to change. Changes in these parameters also affect the performance at the user end. It was very critical that causes of attenuation to be eliminated. Conclusion/Recommendations: From the result it can be concluded that, the greater the attenuation, the greater the decrease in power received. It also affects the Q-factor of the system where as the attenuation increase, the maximum Q-factor decreases. As for the minimum BER, minimum BER changes as the attenuation increase initially, after a maximum value it decreases as the attenuation increases.

KW - Adaptor effect

KW - Attenuation increase

KW - Caused mainly

KW - Connector attenuation

KW - Connector effect

KW - Connector reliability

KW - Maximum value

KW - Optical energy

KW - Q-factor decrease

KW - Scattering attenuation

UR - http://www.scopus.com/inward/record.url?scp=83455162625&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=83455162625&partnerID=8YFLogxK

M3 - Article

VL - 9

SP - 186

EP - 195

JO - American Journal of Applied Sciences

JF - American Journal of Applied Sciences

SN - 1546-9239

IS - 2