Właściwości ulepszonego sterownika systemu DVR - dynamicznego odzyskiwania napie{ogonek}cia

Translated title of the contribution: Study of basic properties of an enhanced controller for DVR compensation capabilities

Hannan M A, Azah Mohamed

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

This paper deals with the development of an enhanced controller for investigation of dynamic voltage restorer (DVR) compensation capabilities. Two levels, 24-pulse DVR is modeled with a new control scheme to control the switch signal in the voltage sourced converter. A study on voltage sag compensation capability, harmonic elimination, effect of phase shift on DVR sizing, influence of induction motor load and effect of capacitor value on DVR performance have been investigated. Results proved that the DVR is a suitable device for maximum power quality (PQ) compensation. Thus, the developed model and controller will be useful for further power quality studies in a distribution system.

Original languageUndefined/Unknown
Pages (from-to)293-299
Number of pages7
JournalPrzeglad Elektrotechniczny
Volume88
Issue number4 A
Publication statusPublished - 2012

Fingerprint

Controllers
Electric potential
Power quality
Compensation and Redress
Phase shift
Induction motors
Capacitors
Switches

Keywords

  • Control strategy
  • DVR
  • Power quality
  • Voltage sag

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Właściwości ulepszonego sterownika systemu DVR - dynamicznego odzyskiwania napie{ogonek}cia. / M A, Hannan; Mohamed, Azah.

In: Przeglad Elektrotechniczny, Vol. 88, No. 4 A, 2012, p. 293-299.

Research output: Contribution to journalArticle

@article{0dba0dc2805841b5b6af95008a96d212,
title = "Właściwości ulepszonego sterownika systemu DVR - dynamicznego odzyskiwania napie{ogonek}cia",
abstract = "This paper deals with the development of an enhanced controller for investigation of dynamic voltage restorer (DVR) compensation capabilities. Two levels, 24-pulse DVR is modeled with a new control scheme to control the switch signal in the voltage sourced converter. A study on voltage sag compensation capability, harmonic elimination, effect of phase shift on DVR sizing, influence of induction motor load and effect of capacitor value on DVR performance have been investigated. Results proved that the DVR is a suitable device for maximum power quality (PQ) compensation. Thus, the developed model and controller will be useful for further power quality studies in a distribution system.",
keywords = "Control strategy, DVR, Power quality, Voltage sag",
author = "{M A}, Hannan and Azah Mohamed",
year = "2012",
language = "Undefined/Unknown",
volume = "88",
pages = "293--299",
journal = "Przeglad Elektrotechniczny",
issn = "0033-2097",
publisher = "Wydawnictwo SIGMA - N O T Sp. z o.o.",
number = "4 A",

}

TY - JOUR

T1 - Właściwości ulepszonego sterownika systemu DVR - dynamicznego odzyskiwania napie{ogonek}cia

AU - M A, Hannan

AU - Mohamed, Azah

PY - 2012

Y1 - 2012

N2 - This paper deals with the development of an enhanced controller for investigation of dynamic voltage restorer (DVR) compensation capabilities. Two levels, 24-pulse DVR is modeled with a new control scheme to control the switch signal in the voltage sourced converter. A study on voltage sag compensation capability, harmonic elimination, effect of phase shift on DVR sizing, influence of induction motor load and effect of capacitor value on DVR performance have been investigated. Results proved that the DVR is a suitable device for maximum power quality (PQ) compensation. Thus, the developed model and controller will be useful for further power quality studies in a distribution system.

AB - This paper deals with the development of an enhanced controller for investigation of dynamic voltage restorer (DVR) compensation capabilities. Two levels, 24-pulse DVR is modeled with a new control scheme to control the switch signal in the voltage sourced converter. A study on voltage sag compensation capability, harmonic elimination, effect of phase shift on DVR sizing, influence of induction motor load and effect of capacitor value on DVR performance have been investigated. Results proved that the DVR is a suitable device for maximum power quality (PQ) compensation. Thus, the developed model and controller will be useful for further power quality studies in a distribution system.

KW - Control strategy

KW - DVR

KW - Power quality

KW - Voltage sag

UR - http://www.scopus.com/inward/record.url?scp=84859373508&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859373508&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84859373508

VL - 88

SP - 293

EP - 299

JO - Przeglad Elektrotechniczny

JF - Przeglad Elektrotechniczny

SN - 0033-2097

IS - 4 A

ER -