This paper is concerned with experimental investigations carried out to study the ultimate load behaviour of I-beam to box-column connections stiffened externally. Eight specimens were tested to failure under monotonically increasing load. Different types of stiffener (i.e., external T-stiffeners and angle stiffeners and internal continuity plate stiffeners) were considered in the studies. The connections in all cases were made by butt welding. Ultimate loadcarrying capacity and load-deflection characteristics of these specimens obtained experimentally are compared with the corresponding results obtained by using a non-linear finite element model. Comparisons are also made between the results for different types of stiffener. Different modes of failure for these specimens were observed. T-stiffeners are found to be the most efficient form.

Original languageEnglish
Pages (from-to)269-275
Number of pages7
JournalStructural engineer London
Volume71
Issue number15
Publication statusPublished - 3 Aug 1993
Externally publishedYes

Fingerprint

Butt welding

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Shanmugam, N. E., Ting, L. C., & Lee, S. I. (1993). Static behaviour of I-beam to box-column connections with external stiffeners. Structural engineer London, 71(15), 269-275.

Static behaviour of I-beam to box-column connections with external stiffeners. / Shanmugam, N. E.; Ting, L. C.; Lee, S. I.

In: Structural engineer London, Vol. 71, No. 15, 03.08.1993, p. 269-275.

Research output: Contribution to journalArticle

Shanmugam, NE, Ting, LC & Lee, SI 1993, 'Static behaviour of I-beam to box-column connections with external stiffeners', Structural engineer London, vol. 71, no. 15, pp. 269-275.
Shanmugam, N. E. ; Ting, L. C. ; Lee, S. I. / Static behaviour of I-beam to box-column connections with external stiffeners. In: Structural engineer London. 1993 ; Vol. 71, No. 15. pp. 269-275.
@article{baf50b840d924a898eb628c51e2dbd06,
title = "Static behaviour of I-beam to box-column connections with external stiffeners",
abstract = "This paper is concerned with experimental investigations carried out to study the ultimate load behaviour of I-beam to box-column connections stiffened externally. Eight specimens were tested to failure under monotonically increasing load. Different types of stiffener (i.e., external T-stiffeners and angle stiffeners and internal continuity plate stiffeners) were considered in the studies. The connections in all cases were made by butt welding. Ultimate loadcarrying capacity and load-deflection characteristics of these specimens obtained experimentally are compared with the corresponding results obtained by using a non-linear finite element model. Comparisons are also made between the results for different types of stiffener. Different modes of failure for these specimens were observed. T-stiffeners are found to be the most efficient form.",
author = "Shanmugam, {N. E.} and Ting, {L. C.} and Lee, {S. I.}",
year = "1993",
month = "8",
day = "3",
language = "English",
volume = "71",
pages = "269--275",
journal = "Structural Engineer",
issn = "0039-2553",
publisher = "Institution of Structural Engineers",
number = "15",

}

TY - JOUR

T1 - Static behaviour of I-beam to box-column connections with external stiffeners

AU - Shanmugam, N. E.

AU - Ting, L. C.

AU - Lee, S. I.

PY - 1993/8/3

Y1 - 1993/8/3

N2 - This paper is concerned with experimental investigations carried out to study the ultimate load behaviour of I-beam to box-column connections stiffened externally. Eight specimens were tested to failure under monotonically increasing load. Different types of stiffener (i.e., external T-stiffeners and angle stiffeners and internal continuity plate stiffeners) were considered in the studies. The connections in all cases were made by butt welding. Ultimate loadcarrying capacity and load-deflection characteristics of these specimens obtained experimentally are compared with the corresponding results obtained by using a non-linear finite element model. Comparisons are also made between the results for different types of stiffener. Different modes of failure for these specimens were observed. T-stiffeners are found to be the most efficient form.

AB - This paper is concerned with experimental investigations carried out to study the ultimate load behaviour of I-beam to box-column connections stiffened externally. Eight specimens were tested to failure under monotonically increasing load. Different types of stiffener (i.e., external T-stiffeners and angle stiffeners and internal continuity plate stiffeners) were considered in the studies. The connections in all cases were made by butt welding. Ultimate loadcarrying capacity and load-deflection characteristics of these specimens obtained experimentally are compared with the corresponding results obtained by using a non-linear finite element model. Comparisons are also made between the results for different types of stiffener. Different modes of failure for these specimens were observed. T-stiffeners are found to be the most efficient form.

UR - http://www.scopus.com/inward/record.url?scp=0027907753&partnerID=8YFLogxK