Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique

H. M. Zolkipli, H. Juahir, G. Adiana, N. Zainuddin, A. B.H.M. Maliki, Mohd. Ekhwan Toriman, Mazlin Mokhtar, R. Elfitri

Research output: Contribution to journalArticle

Abstract

This study aims to identify the most significant parameters in drinking water quality, spatial disparities of treated water (TW) and performance of water treatment plant (WTP) in Selangor. Physico- chemical (PCPs), Inorganic (IPs), Heavy metal and organic (HMOPs) and pesticide (PPs) were selected as parameters to discriminate the source of WTP pollutant. Chemometric technique such as principle component analysis (PCA), one-way analysis of variance (ANOVA) and discriminant analysis (DA) was applied to validate the performance of water treatment plant. PCA identified the most significant parameters which are highlighted six out of eight parameters for PCPs, six out of twelve parameters for IPs, nine out of sixteen parameters for HMOPs and all seventh parameters for PP. ANOVA for distinguish two categories region in WTP and showed both of PCPs and IPs had significant differences due to their concentration (p < 0.5) and HMOPs suggested fifth of significant differences within regions (p < 0.05). PP doesn't give any significant differences (p > 0.05). DA was suggested PCPs, IPs and HMOPs in good performance (76.96%, 91.90% and 93.27%) except PP (50.43%). We can conclude that this chemometric technique can expose which area of WTP need to be properly maintains their performance to produce high quality of drinking water.

Original languageEnglish
Pages (from-to)139-146
Number of pages8
JournalInternational Journal of Engineering and Technology(UAE)
Volume7
Issue number3.14 Special Issue 14
Publication statusPublished - 1 Jan 2018

Fingerprint

Water treatment plants
Water Purification
Malaysia
Pesticides
Analysis of Variance
Discriminant Analysis
Discriminant analysis
Analysis of variance (ANOVA)
Potable water
Drinking Water
Inorganic Chemicals
Inorganic chemicals
Water Quality
Heavy Metals
Heavy metals
Water quality
Water

Keywords

  • Discriminant analysis
  • Drinking water quality
  • One-way analysis of variance
  • Principal component analysis
  • Water treatment plant

ASJC Scopus subject areas

  • Biotechnology
  • Computer Science (miscellaneous)
  • Environmental Engineering
  • Chemical Engineering(all)
  • Engineering(all)
  • Hardware and Architecture

Cite this

Zolkipli, H. M., Juahir, H., Adiana, G., Zainuddin, N., Maliki, A. B. H. M., Toriman, M. E., ... Elfitri, R. (2018). Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique. International Journal of Engineering and Technology(UAE), 7(3.14 Special Issue 14), 139-146.

Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique. / Zolkipli, H. M.; Juahir, H.; Adiana, G.; Zainuddin, N.; Maliki, A. B.H.M.; Toriman, Mohd. Ekhwan; Mokhtar, Mazlin; Elfitri, R.

In: International Journal of Engineering and Technology(UAE), Vol. 7, No. 3.14 Special Issue 14, 01.01.2018, p. 139-146.

Research output: Contribution to journalArticle

Zolkipli, HM, Juahir, H, Adiana, G, Zainuddin, N, Maliki, ABHM, Toriman, ME, Mokhtar, M & Elfitri, R 2018, 'Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique', International Journal of Engineering and Technology(UAE), vol. 7, no. 3.14 Special Issue 14, pp. 139-146.
Zolkipli, H. M. ; Juahir, H. ; Adiana, G. ; Zainuddin, N. ; Maliki, A. B.H.M. ; Toriman, Mohd. Ekhwan ; Mokhtar, Mazlin ; Elfitri, R. / Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique. In: International Journal of Engineering and Technology(UAE). 2018 ; Vol. 7, No. 3.14 Special Issue 14. pp. 139-146.
@article{8668d4b982034aa5b4a58450bce533db,
title = "Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique",
abstract = "This study aims to identify the most significant parameters in drinking water quality, spatial disparities of treated water (TW) and performance of water treatment plant (WTP) in Selangor. Physico- chemical (PCPs), Inorganic (IPs), Heavy metal and organic (HMOPs) and pesticide (PPs) were selected as parameters to discriminate the source of WTP pollutant. Chemometric technique such as principle component analysis (PCA), one-way analysis of variance (ANOVA) and discriminant analysis (DA) was applied to validate the performance of water treatment plant. PCA identified the most significant parameters which are highlighted six out of eight parameters for PCPs, six out of twelve parameters for IPs, nine out of sixteen parameters for HMOPs and all seventh parameters for PP. ANOVA for distinguish two categories region in WTP and showed both of PCPs and IPs had significant differences due to their concentration (p < 0.5) and HMOPs suggested fifth of significant differences within regions (p < 0.05). PP doesn't give any significant differences (p > 0.05). DA was suggested PCPs, IPs and HMOPs in good performance (76.96{\%}, 91.90{\%} and 93.27{\%}) except PP (50.43{\%}). We can conclude that this chemometric technique can expose which area of WTP need to be properly maintains their performance to produce high quality of drinking water.",
keywords = "Discriminant analysis, Drinking water quality, One-way analysis of variance, Principal component analysis, Water treatment plant",
author = "Zolkipli, {H. M.} and H. Juahir and G. Adiana and N. Zainuddin and Maliki, {A. B.H.M.} and Toriman, {Mohd. Ekhwan} and Mazlin Mokhtar and R. Elfitri",
year = "2018",
month = "1",
day = "1",
language = "English",
volume = "7",
pages = "139--146",
journal = "International Journal of Engineering and Technology(UAE)",
issn = "2227-524X",
publisher = "Science Publishing Corporation Inc",
number = "3.14 Special Issue 14",

}

TY - JOUR

T1 - Spatial assessment of Selangor, Malaysia water treatment plant performance using chemometric technique

AU - Zolkipli, H. M.

AU - Juahir, H.

AU - Adiana, G.

AU - Zainuddin, N.

AU - Maliki, A. B.H.M.

AU - Toriman, Mohd. Ekhwan

AU - Mokhtar, Mazlin

AU - Elfitri, R.

PY - 2018/1/1

Y1 - 2018/1/1

N2 - This study aims to identify the most significant parameters in drinking water quality, spatial disparities of treated water (TW) and performance of water treatment plant (WTP) in Selangor. Physico- chemical (PCPs), Inorganic (IPs), Heavy metal and organic (HMOPs) and pesticide (PPs) were selected as parameters to discriminate the source of WTP pollutant. Chemometric technique such as principle component analysis (PCA), one-way analysis of variance (ANOVA) and discriminant analysis (DA) was applied to validate the performance of water treatment plant. PCA identified the most significant parameters which are highlighted six out of eight parameters for PCPs, six out of twelve parameters for IPs, nine out of sixteen parameters for HMOPs and all seventh parameters for PP. ANOVA for distinguish two categories region in WTP and showed both of PCPs and IPs had significant differences due to their concentration (p < 0.5) and HMOPs suggested fifth of significant differences within regions (p < 0.05). PP doesn't give any significant differences (p > 0.05). DA was suggested PCPs, IPs and HMOPs in good performance (76.96%, 91.90% and 93.27%) except PP (50.43%). We can conclude that this chemometric technique can expose which area of WTP need to be properly maintains their performance to produce high quality of drinking water.

AB - This study aims to identify the most significant parameters in drinking water quality, spatial disparities of treated water (TW) and performance of water treatment plant (WTP) in Selangor. Physico- chemical (PCPs), Inorganic (IPs), Heavy metal and organic (HMOPs) and pesticide (PPs) were selected as parameters to discriminate the source of WTP pollutant. Chemometric technique such as principle component analysis (PCA), one-way analysis of variance (ANOVA) and discriminant analysis (DA) was applied to validate the performance of water treatment plant. PCA identified the most significant parameters which are highlighted six out of eight parameters for PCPs, six out of twelve parameters for IPs, nine out of sixteen parameters for HMOPs and all seventh parameters for PP. ANOVA for distinguish two categories region in WTP and showed both of PCPs and IPs had significant differences due to their concentration (p < 0.5) and HMOPs suggested fifth of significant differences within regions (p < 0.05). PP doesn't give any significant differences (p > 0.05). DA was suggested PCPs, IPs and HMOPs in good performance (76.96%, 91.90% and 93.27%) except PP (50.43%). We can conclude that this chemometric technique can expose which area of WTP need to be properly maintains their performance to produce high quality of drinking water.

KW - Discriminant analysis

KW - Drinking water quality

KW - One-way analysis of variance

KW - Principal component analysis

KW - Water treatment plant

UR - http://www.scopus.com/inward/record.url?scp=85052975109&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052975109&partnerID=8YFLogxK

M3 - Article

VL - 7

SP - 139

EP - 146

JO - International Journal of Engineering and Technology(UAE)

JF - International Journal of Engineering and Technology(UAE)

SN - 2227-524X

IS - 3.14 Special Issue 14

ER -