Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance

Yushaizad Yusof, Nasrudin Abd Rahim

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper discusses a simulation study for series hybrid active power Alter which is a combination of series active power Alter and passive power filter in order to mitigate source current harmonics produced by nonlinear loads. Hence, shunt connected passive filters suppress current harmonics drawn by the loads, whereas the series active filters acts as a harmonic isolator between the source and load. A control method based on synchronous reference frame (SRF) is implemented in compensation of source current harmonics. Derived reference voltage for source current harmonics compensation is fired via space vector pulse width modulator (SVPWM) as gating signals for voltage source inverter (VSI). The Matlab/Simulink software is implemented for simulation and modelling the system. As a result, the proposed system is significantly mitigates source current harmonics to the level that comply the power system harmonics standard.

Original languageEnglish
Title of host publicationInternational Conference for Technical Postgraduates 2009, TECHPOS 2009
DOIs
Publication statusPublished - 2009
EventInternational Conference for Technical Postgraduates 2009, TECHPOS 2009 - Kuala Lumpur
Duration: 14 Dec 200915 Dec 2009

Other

OtherInternational Conference for Technical Postgraduates 2009, TECHPOS 2009
CityKuala Lumpur
Period14/12/0915/12/09

Fingerprint

Vector spaces
Modulators
Passive filters
Active filters
Electric potential
Compensation and Redress

ASJC Scopus subject areas

  • Computer Science(all)
  • Engineering(all)
  • Environmental Engineering

Cite this

Yusof, Y., & Rahim, N. A. (2009). Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance. In International Conference for Technical Postgraduates 2009, TECHPOS 2009 [5412070] https://doi.org/10.1109/TECHPOS.2009.5412070

Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance. / Yusof, Yushaizad; Rahim, Nasrudin Abd.

International Conference for Technical Postgraduates 2009, TECHPOS 2009. 2009. 5412070.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yusof, Y & Rahim, NA 2009, Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance. in International Conference for Technical Postgraduates 2009, TECHPOS 2009., 5412070, International Conference for Technical Postgraduates 2009, TECHPOS 2009, Kuala Lumpur, 14/12/09. https://doi.org/10.1109/TECHPOS.2009.5412070
Yusof, Yushaizad ; Rahim, Nasrudin Abd. / Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance. International Conference for Technical Postgraduates 2009, TECHPOS 2009. 2009.
@inproceedings{331e58cb9d5441a89d565359562d4814,
title = "Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance",
abstract = "This paper discusses a simulation study for series hybrid active power Alter which is a combination of series active power Alter and passive power filter in order to mitigate source current harmonics produced by nonlinear loads. Hence, shunt connected passive filters suppress current harmonics drawn by the loads, whereas the series active filters acts as a harmonic isolator between the source and load. A control method based on synchronous reference frame (SRF) is implemented in compensation of source current harmonics. Derived reference voltage for source current harmonics compensation is fired via space vector pulse width modulator (SVPWM) as gating signals for voltage source inverter (VSI). The Matlab/Simulink software is implemented for simulation and modelling the system. As a result, the proposed system is significantly mitigates source current harmonics to the level that comply the power system harmonics standard.",
author = "Yushaizad Yusof and Rahim, {Nasrudin Abd}",
year = "2009",
doi = "10.1109/TECHPOS.2009.5412070",
language = "English",
isbn = "9781424452231",
booktitle = "International Conference for Technical Postgraduates 2009, TECHPOS 2009",

}

TY - GEN

T1 - Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance

AU - Yusof, Yushaizad

AU - Rahim, Nasrudin Abd

PY - 2009

Y1 - 2009

N2 - This paper discusses a simulation study for series hybrid active power Alter which is a combination of series active power Alter and passive power filter in order to mitigate source current harmonics produced by nonlinear loads. Hence, shunt connected passive filters suppress current harmonics drawn by the loads, whereas the series active filters acts as a harmonic isolator between the source and load. A control method based on synchronous reference frame (SRF) is implemented in compensation of source current harmonics. Derived reference voltage for source current harmonics compensation is fired via space vector pulse width modulator (SVPWM) as gating signals for voltage source inverter (VSI). The Matlab/Simulink software is implemented for simulation and modelling the system. As a result, the proposed system is significantly mitigates source current harmonics to the level that comply the power system harmonics standard.

AB - This paper discusses a simulation study for series hybrid active power Alter which is a combination of series active power Alter and passive power filter in order to mitigate source current harmonics produced by nonlinear loads. Hence, shunt connected passive filters suppress current harmonics drawn by the loads, whereas the series active filters acts as a harmonic isolator between the source and load. A control method based on synchronous reference frame (SRF) is implemented in compensation of source current harmonics. Derived reference voltage for source current harmonics compensation is fired via space vector pulse width modulator (SVPWM) as gating signals for voltage source inverter (VSI). The Matlab/Simulink software is implemented for simulation and modelling the system. As a result, the proposed system is significantly mitigates source current harmonics to the level that comply the power system harmonics standard.

UR - http://www.scopus.com/inward/record.url?scp=77950975047&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950975047&partnerID=8YFLogxK

U2 - 10.1109/TECHPOS.2009.5412070

DO - 10.1109/TECHPOS.2009.5412070

M3 - Conference contribution

SN - 9781424452231

BT - International Conference for Technical Postgraduates 2009, TECHPOS 2009