Seismic behaviour of base isolation system using lead rubber bearing

Research output: Contribution to journalArticle

Abstract

Nowadays the main cause of damage of reinforced concrete frames in the countries which are located on the seismic line area is earthquake even though they are designed due to the enactment of seismic codes. To provide a solution to these problems, Lead Rubber Bearing (LRB) system has been utilized in the construction of the buildings. Hence, the objective of this study is to determine the best configuration of the LRB in the structure by calculating the response of the structure, roof level acceleration and inter-story displacement based on the ground motion records. The study consists of determining the structure, calculating the weight of structure, modelling the LRB in the structure and obtaining the output from the dynamic analyses. The comparison of the inter-story displacement, drifts frames and top level acceleration response of the LRB system with the Fixed Base System (FBS) using spectrum and time history analysis shows that the base shear reduces by 65-75% in response spectrum analysis, while in time history analysis base shear reduces by 75-85%. The proposed method is based on the LRB system that reduces the response of the structure because of high damping and stiffness used in the Base Isolation System (BIS) and capable to be used for super structure located in the seismic line area. This system would help in reducing the cost in the long time and increase the safety of the structure.

Original languageEnglish
Pages (from-to)79-88
Number of pages10
JournalJurnal Teknologi (Sciences and Engineering)
Volume65
Issue number2
DOIs
Publication statusPublished - 2013

Fingerprint

Bearings (structural)
Rubber
Lead
Roofs
Spectrum analysis
Reinforced concrete
Earthquakes
Damping
Stiffness
Costs

Keywords

  • Base isolation system
  • Fixed base system
  • LRB system
  • Response spectrum analysis
  • Seismic
  • Time history analysis

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Seismic behaviour of base isolation system using lead rubber bearing. / Hadian, A. V.; A Mutalib, Azrul; Baharom, Shahrizan.

In: Jurnal Teknologi (Sciences and Engineering), Vol. 65, No. 2, 2013, p. 79-88.

Research output: Contribution to journalArticle

@article{4bf9899c06c0481aabb4394388907df9,
title = "Seismic behaviour of base isolation system using lead rubber bearing",
abstract = "Nowadays the main cause of damage of reinforced concrete frames in the countries which are located on the seismic line area is earthquake even though they are designed due to the enactment of seismic codes. To provide a solution to these problems, Lead Rubber Bearing (LRB) system has been utilized in the construction of the buildings. Hence, the objective of this study is to determine the best configuration of the LRB in the structure by calculating the response of the structure, roof level acceleration and inter-story displacement based on the ground motion records. The study consists of determining the structure, calculating the weight of structure, modelling the LRB in the structure and obtaining the output from the dynamic analyses. The comparison of the inter-story displacement, drifts frames and top level acceleration response of the LRB system with the Fixed Base System (FBS) using spectrum and time history analysis shows that the base shear reduces by 65-75{\%} in response spectrum analysis, while in time history analysis base shear reduces by 75-85{\%}. The proposed method is based on the LRB system that reduces the response of the structure because of high damping and stiffness used in the Base Isolation System (BIS) and capable to be used for super structure located in the seismic line area. This system would help in reducing the cost in the long time and increase the safety of the structure.",
keywords = "Base isolation system, Fixed base system, LRB system, Response spectrum analysis, Seismic, Time history analysis",
author = "Hadian, {A. V.} and {A Mutalib}, Azrul and Shahrizan Baharom",
year = "2013",
doi = "10.11113/jt.v65.2195",
language = "English",
volume = "65",
pages = "79--88",
journal = "Jurnal Teknologi",
issn = "0127-9696",
publisher = "Penerbit Universiti Teknologi Malaysia",
number = "2",

}

TY - JOUR

T1 - Seismic behaviour of base isolation system using lead rubber bearing

AU - Hadian, A. V.

AU - A Mutalib, Azrul

AU - Baharom, Shahrizan

PY - 2013

Y1 - 2013

N2 - Nowadays the main cause of damage of reinforced concrete frames in the countries which are located on the seismic line area is earthquake even though they are designed due to the enactment of seismic codes. To provide a solution to these problems, Lead Rubber Bearing (LRB) system has been utilized in the construction of the buildings. Hence, the objective of this study is to determine the best configuration of the LRB in the structure by calculating the response of the structure, roof level acceleration and inter-story displacement based on the ground motion records. The study consists of determining the structure, calculating the weight of structure, modelling the LRB in the structure and obtaining the output from the dynamic analyses. The comparison of the inter-story displacement, drifts frames and top level acceleration response of the LRB system with the Fixed Base System (FBS) using spectrum and time history analysis shows that the base shear reduces by 65-75% in response spectrum analysis, while in time history analysis base shear reduces by 75-85%. The proposed method is based on the LRB system that reduces the response of the structure because of high damping and stiffness used in the Base Isolation System (BIS) and capable to be used for super structure located in the seismic line area. This system would help in reducing the cost in the long time and increase the safety of the structure.

AB - Nowadays the main cause of damage of reinforced concrete frames in the countries which are located on the seismic line area is earthquake even though they are designed due to the enactment of seismic codes. To provide a solution to these problems, Lead Rubber Bearing (LRB) system has been utilized in the construction of the buildings. Hence, the objective of this study is to determine the best configuration of the LRB in the structure by calculating the response of the structure, roof level acceleration and inter-story displacement based on the ground motion records. The study consists of determining the structure, calculating the weight of structure, modelling the LRB in the structure and obtaining the output from the dynamic analyses. The comparison of the inter-story displacement, drifts frames and top level acceleration response of the LRB system with the Fixed Base System (FBS) using spectrum and time history analysis shows that the base shear reduces by 65-75% in response spectrum analysis, while in time history analysis base shear reduces by 75-85%. The proposed method is based on the LRB system that reduces the response of the structure because of high damping and stiffness used in the Base Isolation System (BIS) and capable to be used for super structure located in the seismic line area. This system would help in reducing the cost in the long time and increase the safety of the structure.

KW - Base isolation system

KW - Fixed base system

KW - LRB system

KW - Response spectrum analysis

KW - Seismic

KW - Time history analysis

UR - http://www.scopus.com/inward/record.url?scp=84888229468&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84888229468&partnerID=8YFLogxK

U2 - 10.11113/jt.v65.2195

DO - 10.11113/jt.v65.2195

M3 - Article

VL - 65

SP - 79

EP - 88

JO - Jurnal Teknologi

JF - Jurnal Teknologi

SN - 0127-9696

IS - 2