Restoration scheme implementation in automatic protection unit for FTTH passive optical network

Siti Asma Che Aziz, Mohd Syuhaimi Ab Rahman, Siti Rahayu Hassan, Kasmiran Jumari

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

this paper focused on the implementation of automatic device switching to perform in restoration scheme located at distribution fiber section. This protection device is potentially will improve the system efficiency in order to provide the continuous data flow until it reach to the end user. We proposed for immediate split structure in EPON network when the signal is totally split when it pass through the optical splitter. The restoration scheme proposed in this paper was presented and the simulation results proved the system feasibility. The bit error rate (BER) performances are measured by a 1.25 Gp/s non- return-to zero (NRZ) pseudo random binary sequence (PBRS) with a pattern length of 231-1 for the downstream traffic between OLT and 8 ONUs. Our results were obtained by observing bit error rates, eye diagram, and optical power levels.

Original languageEnglish
Title of host publicationProceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009
Pages459-462
Number of pages4
Volume2
DOIs
Publication statusPublished - 2009
Event2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009 - Selangor
Duration: 5 Aug 20097 Aug 2009

Other

Other2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009
CitySelangor
Period5/8/097/8/09

Fingerprint

Passive optical networks
Bit error rate
Restoration
Binary sequences
Fibers
Fiber to the x

Keywords

  • Aotumatic switching FTTH
  • Distribution fiber
  • EPON
  • Restoration scheme

ASJC Scopus subject areas

  • Information Systems
  • Software
  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Che Aziz, S. A., Ab Rahman, M. S., Hassan, S. R., & Jumari, K. (2009). Restoration scheme implementation in automatic protection unit for FTTH passive optical network. In Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009 (Vol. 2, pp. 459-462). [5254692] https://doi.org/10.1109/ICEEI.2009.5254692

Restoration scheme implementation in automatic protection unit for FTTH passive optical network. / Che Aziz, Siti Asma; Ab Rahman, Mohd Syuhaimi; Hassan, Siti Rahayu; Jumari, Kasmiran.

Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 2 2009. p. 459-462 5254692.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Che Aziz, SA, Ab Rahman, MS, Hassan, SR & Jumari, K 2009, Restoration scheme implementation in automatic protection unit for FTTH passive optical network. in Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. vol. 2, 5254692, pp. 459-462, 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009, Selangor, 5/8/09. https://doi.org/10.1109/ICEEI.2009.5254692
Che Aziz SA, Ab Rahman MS, Hassan SR, Jumari K. Restoration scheme implementation in automatic protection unit for FTTH passive optical network. In Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 2. 2009. p. 459-462. 5254692 https://doi.org/10.1109/ICEEI.2009.5254692
Che Aziz, Siti Asma ; Ab Rahman, Mohd Syuhaimi ; Hassan, Siti Rahayu ; Jumari, Kasmiran. / Restoration scheme implementation in automatic protection unit for FTTH passive optical network. Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 2 2009. pp. 459-462
@inproceedings{1f629cf8b9614953b5686760cc53ea46,
title = "Restoration scheme implementation in automatic protection unit for FTTH passive optical network",
abstract = "this paper focused on the implementation of automatic device switching to perform in restoration scheme located at distribution fiber section. This protection device is potentially will improve the system efficiency in order to provide the continuous data flow until it reach to the end user. We proposed for immediate split structure in EPON network when the signal is totally split when it pass through the optical splitter. The restoration scheme proposed in this paper was presented and the simulation results proved the system feasibility. The bit error rate (BER) performances are measured by a 1.25 Gp/s non- return-to zero (NRZ) pseudo random binary sequence (PBRS) with a pattern length of 231-1 for the downstream traffic between OLT and 8 ONUs. Our results were obtained by observing bit error rates, eye diagram, and optical power levels.",
keywords = "Aotumatic switching FTTH, Distribution fiber, EPON, Restoration scheme",
author = "{Che Aziz}, {Siti Asma} and {Ab Rahman}, {Mohd Syuhaimi} and Hassan, {Siti Rahayu} and Kasmiran Jumari",
year = "2009",
doi = "10.1109/ICEEI.2009.5254692",
language = "English",
isbn = "9781424449132",
volume = "2",
pages = "459--462",
booktitle = "Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009",

}

TY - GEN

T1 - Restoration scheme implementation in automatic protection unit for FTTH passive optical network

AU - Che Aziz, Siti Asma

AU - Ab Rahman, Mohd Syuhaimi

AU - Hassan, Siti Rahayu

AU - Jumari, Kasmiran

PY - 2009

Y1 - 2009

N2 - this paper focused on the implementation of automatic device switching to perform in restoration scheme located at distribution fiber section. This protection device is potentially will improve the system efficiency in order to provide the continuous data flow until it reach to the end user. We proposed for immediate split structure in EPON network when the signal is totally split when it pass through the optical splitter. The restoration scheme proposed in this paper was presented and the simulation results proved the system feasibility. The bit error rate (BER) performances are measured by a 1.25 Gp/s non- return-to zero (NRZ) pseudo random binary sequence (PBRS) with a pattern length of 231-1 for the downstream traffic between OLT and 8 ONUs. Our results were obtained by observing bit error rates, eye diagram, and optical power levels.

AB - this paper focused on the implementation of automatic device switching to perform in restoration scheme located at distribution fiber section. This protection device is potentially will improve the system efficiency in order to provide the continuous data flow until it reach to the end user. We proposed for immediate split structure in EPON network when the signal is totally split when it pass through the optical splitter. The restoration scheme proposed in this paper was presented and the simulation results proved the system feasibility. The bit error rate (BER) performances are measured by a 1.25 Gp/s non- return-to zero (NRZ) pseudo random binary sequence (PBRS) with a pattern length of 231-1 for the downstream traffic between OLT and 8 ONUs. Our results were obtained by observing bit error rates, eye diagram, and optical power levels.

KW - Aotumatic switching FTTH

KW - Distribution fiber

KW - EPON

KW - Restoration scheme

UR - http://www.scopus.com/inward/record.url?scp=70449686412&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449686412&partnerID=8YFLogxK

U2 - 10.1109/ICEEI.2009.5254692

DO - 10.1109/ICEEI.2009.5254692

M3 - Conference contribution

SN - 9781424449132

VL - 2

SP - 459

EP - 462

BT - Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009

ER -