Prediction of strength and slump of silica fume incorporated high-performance concrete

Muhammad Fauzi Mohd. Zain, M. R. Karim, M. N. Islam, M. M. Hossain, Maslina Jamil, H. M A Al-Mattarneh

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

This study describes the development of statistical models to predict strength and slump of silica fume incorporated High-Performance Concrete (HPC). Experimental data of silica fume incorporated HPC mixes were used to develop and validate models. The HPC having compressive strength range of 40-113 MPa and slump range of 180-250 mm were used. Statistical models were developed by regression analysis. The results of prediction by the models showed good agreement with those of experiments and other researchers. The developed models can be used to predict slump and 28 days compressive strength of silica fume incorporated HPC.

Original languageEnglish
Pages (from-to)264-277
Number of pages14
JournalAsian Journal of Scientific Research
Volume8
Issue number3
DOIs
Publication statusPublished - 2015

Fingerprint

High performance concrete
Silica fume
Compressive strength
Concrete mixtures
Regression analysis
Experiments
Statistical Models

Keywords

  • High-performance concrete
  • Prediction
  • Regression analysis
  • Silica fume
  • Slump
  • Statistical model
  • Strength

ASJC Scopus subject areas

  • General

Cite this

Prediction of strength and slump of silica fume incorporated high-performance concrete. / Mohd. Zain, Muhammad Fauzi; Karim, M. R.; Islam, M. N.; Hossain, M. M.; Jamil, Maslina; Al-Mattarneh, H. M A.

In: Asian Journal of Scientific Research, Vol. 8, No. 3, 2015, p. 264-277.

Research output: Contribution to journalArticle

Mohd. Zain, Muhammad Fauzi ; Karim, M. R. ; Islam, M. N. ; Hossain, M. M. ; Jamil, Maslina ; Al-Mattarneh, H. M A. / Prediction of strength and slump of silica fume incorporated high-performance concrete. In: Asian Journal of Scientific Research. 2015 ; Vol. 8, No. 3. pp. 264-277.
@article{ed865f34c9cb4420b37bcb0db59bacfc,
title = "Prediction of strength and slump of silica fume incorporated high-performance concrete",
abstract = "This study describes the development of statistical models to predict strength and slump of silica fume incorporated High-Performance Concrete (HPC). Experimental data of silica fume incorporated HPC mixes were used to develop and validate models. The HPC having compressive strength range of 40-113 MPa and slump range of 180-250 mm were used. Statistical models were developed by regression analysis. The results of prediction by the models showed good agreement with those of experiments and other researchers. The developed models can be used to predict slump and 28 days compressive strength of silica fume incorporated HPC.",
keywords = "High-performance concrete, Prediction, Regression analysis, Silica fume, Slump, Statistical model, Strength",
author = "{Mohd. Zain}, {Muhammad Fauzi} and Karim, {M. R.} and Islam, {M. N.} and Hossain, {M. M.} and Maslina Jamil and Al-Mattarneh, {H. M A}",
year = "2015",
doi = "10.3923/ajsr.2015.264.277",
language = "English",
volume = "8",
pages = "264--277",
journal = "Asian Journal of Scientific Research",
issn = "1992-1454",
publisher = "Science Alert Journals",
number = "3",

}

TY - JOUR

T1 - Prediction of strength and slump of silica fume incorporated high-performance concrete

AU - Mohd. Zain, Muhammad Fauzi

AU - Karim, M. R.

AU - Islam, M. N.

AU - Hossain, M. M.

AU - Jamil, Maslina

AU - Al-Mattarneh, H. M A

PY - 2015

Y1 - 2015

N2 - This study describes the development of statistical models to predict strength and slump of silica fume incorporated High-Performance Concrete (HPC). Experimental data of silica fume incorporated HPC mixes were used to develop and validate models. The HPC having compressive strength range of 40-113 MPa and slump range of 180-250 mm were used. Statistical models were developed by regression analysis. The results of prediction by the models showed good agreement with those of experiments and other researchers. The developed models can be used to predict slump and 28 days compressive strength of silica fume incorporated HPC.

AB - This study describes the development of statistical models to predict strength and slump of silica fume incorporated High-Performance Concrete (HPC). Experimental data of silica fume incorporated HPC mixes were used to develop and validate models. The HPC having compressive strength range of 40-113 MPa and slump range of 180-250 mm were used. Statistical models were developed by regression analysis. The results of prediction by the models showed good agreement with those of experiments and other researchers. The developed models can be used to predict slump and 28 days compressive strength of silica fume incorporated HPC.

KW - High-performance concrete

KW - Prediction

KW - Regression analysis

KW - Silica fume

KW - Slump

KW - Statistical model

KW - Strength

UR - http://www.scopus.com/inward/record.url?scp=84933505282&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84933505282&partnerID=8YFLogxK

U2 - 10.3923/ajsr.2015.264.277

DO - 10.3923/ajsr.2015.264.277

M3 - Article

AN - SCOPUS:84933505282

VL - 8

SP - 264

EP - 277

JO - Asian Journal of Scientific Research

JF - Asian Journal of Scientific Research

SN - 1992-1454

IS - 3

ER -