Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application

Mohd Anuar Md Ali, Burhanuddin Yeop Majlis, Aminuddin Ahmad Kayani

Research output: Contribution to journalArticle

Abstract

Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.

Original languageEnglish
Article number012005
JournalIOP Conference Series: Materials Science and Engineering
Volume293
Issue number1
DOIs
Publication statusPublished - 5 Jan 2018

Fingerprint

Electrophoresis
Microelectrodes
Costs

ASJC Scopus subject areas

  • Materials Science(all)
  • Engineering(all)

Cite this

Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application. / Ali, Mohd Anuar Md; Yeop Majlis, Burhanuddin; Kayani, Aminuddin Ahmad.

In: IOP Conference Series: Materials Science and Engineering, Vol. 293, No. 1, 012005, 05.01.2018.

Research output: Contribution to journalArticle

@article{f19993e9ebcc474688ddb2fbc806a39e,
title = "Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application",
abstract = "Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.",
author = "Ali, {Mohd Anuar Md} and {Yeop Majlis}, Burhanuddin and Kayani, {Aminuddin Ahmad}",
year = "2018",
month = "1",
day = "5",
doi = "10.1088/1757-899X/293/1/012005",
language = "English",
volume = "293",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application

AU - Ali, Mohd Anuar Md

AU - Yeop Majlis, Burhanuddin

AU - Kayani, Aminuddin Ahmad

PY - 2018/1/5

Y1 - 2018/1/5

N2 - Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.

AB - Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.

UR - http://www.scopus.com/inward/record.url?scp=85040991551&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040991551&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/293/1/012005

DO - 10.1088/1757-899X/293/1/012005

M3 - Article

VL - 293

JO - IOP Conference Series: Materials Science and Engineering

JF - IOP Conference Series: Materials Science and Engineering

SN - 1757-8981

IS - 1

M1 - 012005

ER -