Power swing detection for correct distance relay operation using S-transform and neural networks

Ahmad Farid Abidin, Azah Mohamed, Hussain Shareef

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

This paper presents an advanced technique for detecting power swings for distance relay operation. It uses a derivative of voltage and signal processing technique called as S-transform for feature extraction. Then an artificial neural network (ANN) is deployed in detecting the unstable swing in power systems. This approach overcomes the traditional relay scheme drawback, by distinguishing a fault, stable swing and unstable swing. To illustrate the effectiveness of the proposed approach, simulations were carried out on the IEEE 39 bus test system using the PSS/E software. Test results show that the proposed approach can effectively differentiate the fault, stable swing and unstable swing with a good accuracy.

Original languageEnglish
Title of host publication2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts
Pages279-284
Number of pages6
DOIs
Publication statusPublished - 2011
Externally publishedYes
Event2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Shah Alam, Selangor
Duration: 6 Jun 20117 Jun 2011

Other

Other2011 5th International Power Engineering and Optimization Conference, PEOCO 2011
CityShah Alam, Selangor
Period6/6/117/6/11

Fingerprint

Feature extraction
Signal processing
Mathematical transformations
Derivatives
Neural networks
Electric potential

Keywords

  • Artificial Neural Network (ANN)
  • Distance relay
  • fault
  • S-transform
  • stable swing and unstable swing

ASJC Scopus subject areas

  • Energy Engineering and Power Technology

Cite this

Abidin, A. F., Mohamed, A., & Shareef, H. (2011). Power swing detection for correct distance relay operation using S-transform and neural networks. In 2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts (pp. 279-284). [5970431] https://doi.org/10.1109/PEOCO.2011.5970431

Power swing detection for correct distance relay operation using S-transform and neural networks. / Abidin, Ahmad Farid; Mohamed, Azah; Shareef, Hussain.

2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts. 2011. p. 279-284 5970431.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abidin, AF, Mohamed, A & Shareef, H 2011, Power swing detection for correct distance relay operation using S-transform and neural networks. in 2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts., 5970431, pp. 279-284, 2011 5th International Power Engineering and Optimization Conference, PEOCO 2011, Shah Alam, Selangor, 6/6/11. https://doi.org/10.1109/PEOCO.2011.5970431
Abidin AF, Mohamed A, Shareef H. Power swing detection for correct distance relay operation using S-transform and neural networks. In 2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts. 2011. p. 279-284. 5970431 https://doi.org/10.1109/PEOCO.2011.5970431
Abidin, Ahmad Farid ; Mohamed, Azah ; Shareef, Hussain. / Power swing detection for correct distance relay operation using S-transform and neural networks. 2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts. 2011. pp. 279-284
@inproceedings{9346fcdabfda49ce8ab065aee5584c0f,
title = "Power swing detection for correct distance relay operation using S-transform and neural networks",
abstract = "This paper presents an advanced technique for detecting power swings for distance relay operation. It uses a derivative of voltage and signal processing technique called as S-transform for feature extraction. Then an artificial neural network (ANN) is deployed in detecting the unstable swing in power systems. This approach overcomes the traditional relay scheme drawback, by distinguishing a fault, stable swing and unstable swing. To illustrate the effectiveness of the proposed approach, simulations were carried out on the IEEE 39 bus test system using the PSS/E software. Test results show that the proposed approach can effectively differentiate the fault, stable swing and unstable swing with a good accuracy.",
keywords = "Artificial Neural Network (ANN), Distance relay, fault, S-transform, stable swing and unstable swing",
author = "Abidin, {Ahmad Farid} and Azah Mohamed and Hussain Shareef",
year = "2011",
doi = "10.1109/PEOCO.2011.5970431",
language = "English",
isbn = "9781457703546",
pages = "279--284",
booktitle = "2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts",

}

TY - GEN

T1 - Power swing detection for correct distance relay operation using S-transform and neural networks

AU - Abidin, Ahmad Farid

AU - Mohamed, Azah

AU - Shareef, Hussain

PY - 2011

Y1 - 2011

N2 - This paper presents an advanced technique for detecting power swings for distance relay operation. It uses a derivative of voltage and signal processing technique called as S-transform for feature extraction. Then an artificial neural network (ANN) is deployed in detecting the unstable swing in power systems. This approach overcomes the traditional relay scheme drawback, by distinguishing a fault, stable swing and unstable swing. To illustrate the effectiveness of the proposed approach, simulations were carried out on the IEEE 39 bus test system using the PSS/E software. Test results show that the proposed approach can effectively differentiate the fault, stable swing and unstable swing with a good accuracy.

AB - This paper presents an advanced technique for detecting power swings for distance relay operation. It uses a derivative of voltage and signal processing technique called as S-transform for feature extraction. Then an artificial neural network (ANN) is deployed in detecting the unstable swing in power systems. This approach overcomes the traditional relay scheme drawback, by distinguishing a fault, stable swing and unstable swing. To illustrate the effectiveness of the proposed approach, simulations were carried out on the IEEE 39 bus test system using the PSS/E software. Test results show that the proposed approach can effectively differentiate the fault, stable swing and unstable swing with a good accuracy.

KW - Artificial Neural Network (ANN)

KW - Distance relay

KW - fault

KW - S-transform

KW - stable swing and unstable swing

UR - http://www.scopus.com/inward/record.url?scp=80052301776&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052301776&partnerID=8YFLogxK

U2 - 10.1109/PEOCO.2011.5970431

DO - 10.1109/PEOCO.2011.5970431

M3 - Conference contribution

AN - SCOPUS:80052301776

SN - 9781457703546

SP - 279

EP - 284

BT - 2011 5th International Power Engineering and Optimization Conference, PEOCO 2011 - Program and Abstracts

ER -