Analiza jakości energii w sieci elektroenergetycznej z doła{ogonek}czonymi systemami fotowoltaicznymi

Translated title of the contribution: Power Quality Analysis of Grid-Connected Photovoltaic Systems in Distribution Networks

Masoud Farhoodnea, Azah Mohamed, Hussain Shareef, Hadi Zayandehroodi

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

This paper presents a dynamic PQ analysis on the effects of high-penetrated grid-connected photovoltaic (PV) systems in a distribution system under different weather conditions. To track practical considerations, all information on PV units and weather conditions given in this paper were collected from different solar panel producers and from the Malaysian Meteorological Department (MMD), respectively. A 1.8-MW gridconnected PV system in a radial 16-bus test system is modeled and simulated using Matlab/Simulink software to study the effects of this technology on the system under different levels of solar irradiation. The simulation results proved that the presence of high-penetrated grid-connected PV systems could cause power quality problems such as voltage raise, voltage flicker, and power factor reduction.

Original languageUndefined/Unknown
Pages (from-to)208-213
Number of pages6
JournalPrzeglad Elektrotechniczny
Volume89
Issue number2 A
Publication statusPublished - 2013

Fingerprint

Power quality
Electric power distribution
Electric potential
Dynamic analysis
Irradiation

Keywords

  • Distributed generation
  • Flicker
  • Photovoltaic systems
  • Power quality
  • Renewable energy
  • Voltage fluctuation

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Analiza jakości energii w sieci elektroenergetycznej z doła{ogonek}czonymi systemami fotowoltaicznymi. / Farhoodnea, Masoud; Mohamed, Azah; Shareef, Hussain; Zayandehroodi, Hadi.

In: Przeglad Elektrotechniczny, Vol. 89, No. 2 A, 2013, p. 208-213.

Research output: Contribution to journalArticle

Farhoodnea, Masoud ; Mohamed, Azah ; Shareef, Hussain ; Zayandehroodi, Hadi. / Analiza jakości energii w sieci elektroenergetycznej z doła{ogonek}czonymi systemami fotowoltaicznymi. In: Przeglad Elektrotechniczny. 2013 ; Vol. 89, No. 2 A. pp. 208-213.
@article{ee62a2ecb9ad4a588be7fa80338b08ab,
title = "Analiza jakości energii w sieci elektroenergetycznej z doła{ogonek}czonymi systemami fotowoltaicznymi",
abstract = "This paper presents a dynamic PQ analysis on the effects of high-penetrated grid-connected photovoltaic (PV) systems in a distribution system under different weather conditions. To track practical considerations, all information on PV units and weather conditions given in this paper were collected from different solar panel producers and from the Malaysian Meteorological Department (MMD), respectively. A 1.8-MW gridconnected PV system in a radial 16-bus test system is modeled and simulated using Matlab/Simulink software to study the effects of this technology on the system under different levels of solar irradiation. The simulation results proved that the presence of high-penetrated grid-connected PV systems could cause power quality problems such as voltage raise, voltage flicker, and power factor reduction.",
keywords = "Distributed generation, Flicker, Photovoltaic systems, Power quality, Renewable energy, Voltage fluctuation",
author = "Masoud Farhoodnea and Azah Mohamed and Hussain Shareef and Hadi Zayandehroodi",
year = "2013",
language = "Undefined/Unknown",
volume = "89",
pages = "208--213",
journal = "Przeglad Elektrotechniczny",
issn = "0033-2097",
publisher = "Wydawnictwo SIGMA - N O T Sp. z o.o.",
number = "2 A",

}

TY - JOUR

T1 - Analiza jakości energii w sieci elektroenergetycznej z doła{ogonek}czonymi systemami fotowoltaicznymi

AU - Farhoodnea, Masoud

AU - Mohamed, Azah

AU - Shareef, Hussain

AU - Zayandehroodi, Hadi

PY - 2013

Y1 - 2013

N2 - This paper presents a dynamic PQ analysis on the effects of high-penetrated grid-connected photovoltaic (PV) systems in a distribution system under different weather conditions. To track practical considerations, all information on PV units and weather conditions given in this paper were collected from different solar panel producers and from the Malaysian Meteorological Department (MMD), respectively. A 1.8-MW gridconnected PV system in a radial 16-bus test system is modeled and simulated using Matlab/Simulink software to study the effects of this technology on the system under different levels of solar irradiation. The simulation results proved that the presence of high-penetrated grid-connected PV systems could cause power quality problems such as voltage raise, voltage flicker, and power factor reduction.

AB - This paper presents a dynamic PQ analysis on the effects of high-penetrated grid-connected photovoltaic (PV) systems in a distribution system under different weather conditions. To track practical considerations, all information on PV units and weather conditions given in this paper were collected from different solar panel producers and from the Malaysian Meteorological Department (MMD), respectively. A 1.8-MW gridconnected PV system in a radial 16-bus test system is modeled and simulated using Matlab/Simulink software to study the effects of this technology on the system under different levels of solar irradiation. The simulation results proved that the presence of high-penetrated grid-connected PV systems could cause power quality problems such as voltage raise, voltage flicker, and power factor reduction.

KW - Distributed generation

KW - Flicker

KW - Photovoltaic systems

KW - Power quality

KW - Renewable energy

KW - Voltage fluctuation

UR - http://www.scopus.com/inward/record.url?scp=84874220157&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874220157&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84874220157

VL - 89

SP - 208

EP - 213

JO - Przeglad Elektrotechniczny

JF - Przeglad Elektrotechniczny

SN - 0033-2097

IS - 2 A

ER -