Atrial Fibrillation (AF) is one of the most challenging heart ailments to be detected due to its nature being intermittent in early stage of its presence. The challenges become greater when early detection found to be the best treatment method. Currently, guidelines for the early detection and treatment of occult AF are limited. Electrophysiology study is most reliable noninvasive screening method used in AF detection. Electrocardiogram (ECG) is the present electrophysiological measurement in clinical practice. In this study, Photoplethysmogram (PPG) based physiological measurement is introduced through heart rate variability and cardiac cycle fitness as the potential AF screening index. Seven subjects, one normal and six clinically confirmed AF patient's PPG were recorded. All patient's blood profile (INR and blood glucose) and blood pressure measurement were retrieved from pass clinical record. Infographic and data visualization technique were adopted in presenting the AF presence in PPG signal. This preliminary result has provided a foundation for AF detection by using PPG waveforms. PPG is known for its simplicity in terms of cost and utility which able to provide an opportunity to be introduced as home-based AF monitoring tool.

Original languageEnglish
Pages (from-to)1946-1951
Number of pages6
JournalJournal of Engineering and Applied Sciences
Volume12
Issue number8
DOIs
Publication statusPublished - 2017

Fingerprint

Photoplethysmography
Screening
Blood
Electrophysiology
Data visualization
Blood pressure
Pressure measurement
Electrocardiography
Glucose
Monitoring
Costs

Keywords

  • Atrial Fibrillation
  • International normalized ratio
  • Paroxysmal
  • Persistence
  • Photoplethysmography

ASJC Scopus subject areas

  • Engineering(all)

Cite this

@article{9ca75238a7ae4900ba3e3f180441bedc,
title = "Photoplethysmography signal in paroxysmal and persistence atrial fibrillation patients",
abstract = "Atrial Fibrillation (AF) is one of the most challenging heart ailments to be detected due to its nature being intermittent in early stage of its presence. The challenges become greater when early detection found to be the best treatment method. Currently, guidelines for the early detection and treatment of occult AF are limited. Electrophysiology study is most reliable noninvasive screening method used in AF detection. Electrocardiogram (ECG) is the present electrophysiological measurement in clinical practice. In this study, Photoplethysmogram (PPG) based physiological measurement is introduced through heart rate variability and cardiac cycle fitness as the potential AF screening index. Seven subjects, one normal and six clinically confirmed AF patient's PPG were recorded. All patient's blood profile (INR and blood glucose) and blood pressure measurement were retrieved from pass clinical record. Infographic and data visualization technique were adopted in presenting the AF presence in PPG signal. This preliminary result has provided a foundation for AF detection by using PPG waveforms. PPG is known for its simplicity in terms of cost and utility which able to provide an opportunity to be introduced as home-based AF monitoring tool.",
keywords = "Atrial Fibrillation, International normalized ratio, Paroxysmal, Persistence, Photoplethysmography",
author = "Kalaivani Chell and {Nur Hidayah Malek}, S. and Rosmina Jaafar and Amilia Aminuddin",
year = "2017",
doi = "10.3923/jeasci.2017.1946.1951",
language = "English",
volume = "12",
pages = "1946--1951",
journal = "Journal of Engineering and Applied Sciences",
issn = "1816-949X",
publisher = "Medwell Journals",
number = "8",

}

TY - JOUR

T1 - Photoplethysmography signal in paroxysmal and persistence atrial fibrillation patients

AU - Chell, Kalaivani

AU - Nur Hidayah Malek, S.

AU - Jaafar, Rosmina

AU - Aminuddin, Amilia

PY - 2017

Y1 - 2017

N2 - Atrial Fibrillation (AF) is one of the most challenging heart ailments to be detected due to its nature being intermittent in early stage of its presence. The challenges become greater when early detection found to be the best treatment method. Currently, guidelines for the early detection and treatment of occult AF are limited. Electrophysiology study is most reliable noninvasive screening method used in AF detection. Electrocardiogram (ECG) is the present electrophysiological measurement in clinical practice. In this study, Photoplethysmogram (PPG) based physiological measurement is introduced through heart rate variability and cardiac cycle fitness as the potential AF screening index. Seven subjects, one normal and six clinically confirmed AF patient's PPG were recorded. All patient's blood profile (INR and blood glucose) and blood pressure measurement were retrieved from pass clinical record. Infographic and data visualization technique were adopted in presenting the AF presence in PPG signal. This preliminary result has provided a foundation for AF detection by using PPG waveforms. PPG is known for its simplicity in terms of cost and utility which able to provide an opportunity to be introduced as home-based AF monitoring tool.

AB - Atrial Fibrillation (AF) is one of the most challenging heart ailments to be detected due to its nature being intermittent in early stage of its presence. The challenges become greater when early detection found to be the best treatment method. Currently, guidelines for the early detection and treatment of occult AF are limited. Electrophysiology study is most reliable noninvasive screening method used in AF detection. Electrocardiogram (ECG) is the present electrophysiological measurement in clinical practice. In this study, Photoplethysmogram (PPG) based physiological measurement is introduced through heart rate variability and cardiac cycle fitness as the potential AF screening index. Seven subjects, one normal and six clinically confirmed AF patient's PPG were recorded. All patient's blood profile (INR and blood glucose) and blood pressure measurement were retrieved from pass clinical record. Infographic and data visualization technique were adopted in presenting the AF presence in PPG signal. This preliminary result has provided a foundation for AF detection by using PPG waveforms. PPG is known for its simplicity in terms of cost and utility which able to provide an opportunity to be introduced as home-based AF monitoring tool.

KW - Atrial Fibrillation

KW - International normalized ratio

KW - Paroxysmal

KW - Persistence

KW - Photoplethysmography

UR - http://www.scopus.com/inward/record.url?scp=85021836863&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021836863&partnerID=8YFLogxK