Penuras kuasa aktif pirau satu fasa menggunakan strategi kawalan ringkas

Yushaizad Yusof, Radin Zaim Radin Umar, Nasrudin Abd. Rahim

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This paper describes a single phase shunt active power filter system used in compensating current harmonics and improving electrical line’s power factor via simplified control strategy based on estimation of nonlinear load’s equivalent resistance. By employing MATLAB Simulink simulation tool, the proposed control strategy successfully compensated source current harmonics and corrected line power factor to near unity. Moreover, analysis on the system performance indicated that the system’s achieved fast time response, stabilized system and near zero steady state error. To verify the proposed system, experimental results also presented.

Original languageEnglish
Pages (from-to)45-52
Number of pages8
JournalJurnal Teknologi
Volume79
Issue number6
DOIs
Publication statusPublished - 1 Sep 2017

Fingerprint

MATLAB

Keywords

  • Active power filter
  • Equivalent resistance
  • Harmonics
  • Nonlinear load
  • Power factor

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Penuras kuasa aktif pirau satu fasa menggunakan strategi kawalan ringkas. / Yusof, Yushaizad; Umar, Radin Zaim Radin; Abd. Rahim, Nasrudin.

In: Jurnal Teknologi, Vol. 79, No. 6, 01.09.2017, p. 45-52.

Research output: Contribution to journalArticle

Yusof, Yushaizad ; Umar, Radin Zaim Radin ; Abd. Rahim, Nasrudin. / Penuras kuasa aktif pirau satu fasa menggunakan strategi kawalan ringkas. In: Jurnal Teknologi. 2017 ; Vol. 79, No. 6. pp. 45-52.
@article{dd077f31223a4bd688618c4153a82806,
title = "Penuras kuasa aktif pirau satu fasa menggunakan strategi kawalan ringkas",
abstract = "This paper describes a single phase shunt active power filter system used in compensating current harmonics and improving electrical line’s power factor via simplified control strategy based on estimation of nonlinear load’s equivalent resistance. By employing MATLAB Simulink simulation tool, the proposed control strategy successfully compensated source current harmonics and corrected line power factor to near unity. Moreover, analysis on the system performance indicated that the system’s achieved fast time response, stabilized system and near zero steady state error. To verify the proposed system, experimental results also presented.",
keywords = "Active power filter, Equivalent resistance, Harmonics, Nonlinear load, Power factor",
author = "Yushaizad Yusof and Umar, {Radin Zaim Radin} and {Abd. Rahim}, Nasrudin",
year = "2017",
month = "9",
day = "1",
doi = "10.1111./jt.v79.10003",
language = "English",
volume = "79",
pages = "45--52",
journal = "Jurnal Teknologi",
issn = "0127-9696",
publisher = "Penerbit Universiti Teknologi Malaysia",
number = "6",

}

TY - JOUR

T1 - Penuras kuasa aktif pirau satu fasa menggunakan strategi kawalan ringkas

AU - Yusof, Yushaizad

AU - Umar, Radin Zaim Radin

AU - Abd. Rahim, Nasrudin

PY - 2017/9/1

Y1 - 2017/9/1

N2 - This paper describes a single phase shunt active power filter system used in compensating current harmonics and improving electrical line’s power factor via simplified control strategy based on estimation of nonlinear load’s equivalent resistance. By employing MATLAB Simulink simulation tool, the proposed control strategy successfully compensated source current harmonics and corrected line power factor to near unity. Moreover, analysis on the system performance indicated that the system’s achieved fast time response, stabilized system and near zero steady state error. To verify the proposed system, experimental results also presented.

AB - This paper describes a single phase shunt active power filter system used in compensating current harmonics and improving electrical line’s power factor via simplified control strategy based on estimation of nonlinear load’s equivalent resistance. By employing MATLAB Simulink simulation tool, the proposed control strategy successfully compensated source current harmonics and corrected line power factor to near unity. Moreover, analysis on the system performance indicated that the system’s achieved fast time response, stabilized system and near zero steady state error. To verify the proposed system, experimental results also presented.

KW - Active power filter

KW - Equivalent resistance

KW - Harmonics

KW - Nonlinear load

KW - Power factor

UR - http://www.scopus.com/inward/record.url?scp=85028559770&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028559770&partnerID=8YFLogxK

U2 - 10.1111./jt.v79.10003

DO - 10.1111./jt.v79.10003

M3 - Article

AN - SCOPUS:85028559770

VL - 79

SP - 45

EP - 52

JO - Jurnal Teknologi

JF - Jurnal Teknologi

SN - 0127-9696

IS - 6

ER -