Parametric differential approach for modeling the upper limb human vasculature

Edmond Zahedi, Mohd Alauddin Mohd Ali

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    5 Citations (Scopus)

    Abstract

    A parametric approach is proposed for the characterization of the upper vascular tree. The novelty of the approach resides in it being differential: the processed signals are the photoplethysmograms obtained non-invasively from the left and right indexes. The investigated model is an ARX (auto-regressive with exogenous input) where the order has been estimated utilizing standard techniques. The model coefficients show a relatively high degree of stability.

    Original languageEnglish
    Title of host publicationAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
    Pages742-745
    Number of pages4
    Volume26 I
    Publication statusPublished - 2004
    EventConference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004 - San Francisco, CA, United States
    Duration: 1 Sep 20045 Sep 2004

    Other

    OtherConference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004
    CountryUnited States
    CitySan Francisco, CA
    Period1/9/045/9/04

    Keywords

    • Estimation
    • Photoplethysmogram

    ASJC Scopus subject areas

    • Bioengineering

    Cite this

    Zahedi, E., & Ali, M. A. M. (2004). Parametric differential approach for modeling the upper limb human vasculature. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (Vol. 26 I, pp. 742-745)

    Parametric differential approach for modeling the upper limb human vasculature. / Zahedi, Edmond; Ali, Mohd Alauddin Mohd.

    Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Vol. 26 I 2004. p. 742-745.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Zahedi, E & Ali, MAM 2004, Parametric differential approach for modeling the upper limb human vasculature. in Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. vol. 26 I, pp. 742-745, Conference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004, San Francisco, CA, United States, 1/9/04.
    Zahedi E, Ali MAM. Parametric differential approach for modeling the upper limb human vasculature. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Vol. 26 I. 2004. p. 742-745
    Zahedi, Edmond ; Ali, Mohd Alauddin Mohd. / Parametric differential approach for modeling the upper limb human vasculature. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Vol. 26 I 2004. pp. 742-745
    @inproceedings{713a4b01df1747b790fbf04f8efa2fef,
    title = "Parametric differential approach for modeling the upper limb human vasculature",
    abstract = "A parametric approach is proposed for the characterization of the upper vascular tree. The novelty of the approach resides in it being differential: the processed signals are the photoplethysmograms obtained non-invasively from the left and right indexes. The investigated model is an ARX (auto-regressive with exogenous input) where the order has been estimated utilizing standard techniques. The model coefficients show a relatively high degree of stability.",
    keywords = "Estimation, Photoplethysmogram",
    author = "Edmond Zahedi and Ali, {Mohd Alauddin Mohd}",
    year = "2004",
    language = "English",
    volume = "26 I",
    pages = "742--745",
    booktitle = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",

    }

    TY - GEN

    T1 - Parametric differential approach for modeling the upper limb human vasculature

    AU - Zahedi, Edmond

    AU - Ali, Mohd Alauddin Mohd

    PY - 2004

    Y1 - 2004

    N2 - A parametric approach is proposed for the characterization of the upper vascular tree. The novelty of the approach resides in it being differential: the processed signals are the photoplethysmograms obtained non-invasively from the left and right indexes. The investigated model is an ARX (auto-regressive with exogenous input) where the order has been estimated utilizing standard techniques. The model coefficients show a relatively high degree of stability.

    AB - A parametric approach is proposed for the characterization of the upper vascular tree. The novelty of the approach resides in it being differential: the processed signals are the photoplethysmograms obtained non-invasively from the left and right indexes. The investigated model is an ARX (auto-regressive with exogenous input) where the order has been estimated utilizing standard techniques. The model coefficients show a relatively high degree of stability.

    KW - Estimation

    KW - Photoplethysmogram

    UR - http://www.scopus.com/inward/record.url?scp=11044225392&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=11044225392&partnerID=8YFLogxK

    M3 - Conference contribution

    VL - 26 I

    SP - 742

    EP - 745

    BT - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

    ER -