Neural signal processing of mfVEP responses from AMD patients

Yanti Rosli, Xin Lin Goh, Andrew James, Ted Maddess

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Normal healthy subjects and AMD patients were recorded using 64 EEG channels with a computer based acquisition systems using a pattern-pulse mfVEP. A correctly sized head cap (10/20 layout), was placed over the subjects' head. The Fpz electrode holder was placed directly on the 10% nasion-inion mark. The data are simultaneously sampled at 256 Hz per channel, and collected using the ActiveTwo BioSemi data acquisition software.The Active Ag-AgCl electrodes mounted on the head cap was connected to the Biosemi A/D interface box. The stimulus layout was an 84 region per eye cortically-scaled dartboard comprising 12 sectors and 7 concentric rings, subtending a diameter of 23° ; presented dichoptically at 60 Hz frame rate. The 64 electrode channels were held in place with a head cap with a 10/20 layout. Regression models accounting for independent effects were estimated. The Pattern-pulse mfVEP technique is able to record from patients with advance stage AMD. 25.00

Original languageEnglish
Title of host publicationProceedings - International Symposium on Information Technology 2008, ITSim
Volume3
DOIs
Publication statusPublished - 2008
EventInternational Symposium on Information Technology 2008, ITSim - Kuala Lumpur
Duration: 26 Aug 200829 Aug 2008

Other

OtherInternational Symposium on Information Technology 2008, ITSim
CityKuala Lumpur
Period26/8/0829/8/08

Fingerprint

Signal processing
Electrodes
Electroencephalography
Data acquisition

ASJC Scopus subject areas

  • Artificial Intelligence
  • Information Systems
  • Control and Systems Engineering
  • Electrical and Electronic Engineering

Cite this

Rosli, Y., Goh, X. L., James, A., & Maddess, T. (2008). Neural signal processing of mfVEP responses from AMD patients. In Proceedings - International Symposium on Information Technology 2008, ITSim (Vol. 3). [4631854] https://doi.org/10.1109/ITSIM.2008.4631854

Neural signal processing of mfVEP responses from AMD patients. / Rosli, Yanti; Goh, Xin Lin; James, Andrew; Maddess, Ted.

Proceedings - International Symposium on Information Technology 2008, ITSim. Vol. 3 2008. 4631854.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Rosli, Y, Goh, XL, James, A & Maddess, T 2008, Neural signal processing of mfVEP responses from AMD patients. in Proceedings - International Symposium on Information Technology 2008, ITSim. vol. 3, 4631854, International Symposium on Information Technology 2008, ITSim, Kuala Lumpur, 26/8/08. https://doi.org/10.1109/ITSIM.2008.4631854
Rosli Y, Goh XL, James A, Maddess T. Neural signal processing of mfVEP responses from AMD patients. In Proceedings - International Symposium on Information Technology 2008, ITSim. Vol. 3. 2008. 4631854 https://doi.org/10.1109/ITSIM.2008.4631854
Rosli, Yanti ; Goh, Xin Lin ; James, Andrew ; Maddess, Ted. / Neural signal processing of mfVEP responses from AMD patients. Proceedings - International Symposium on Information Technology 2008, ITSim. Vol. 3 2008.
@inproceedings{42b509c369af47dab586ff36bb0b2111,
title = "Neural signal processing of mfVEP responses from AMD patients",
abstract = "Normal healthy subjects and AMD patients were recorded using 64 EEG channels with a computer based acquisition systems using a pattern-pulse mfVEP. A correctly sized head cap (10/20 layout), was placed over the subjects' head. The Fpz electrode holder was placed directly on the 10{\%} nasion-inion mark. The data are simultaneously sampled at 256 Hz per channel, and collected using the ActiveTwo BioSemi data acquisition software.The Active Ag-AgCl electrodes mounted on the head cap was connected to the Biosemi A/D interface box. The stimulus layout was an 84 region per eye cortically-scaled dartboard comprising 12 sectors and 7 concentric rings, subtending a diameter of 23° ; presented dichoptically at 60 Hz frame rate. The 64 electrode channels were held in place with a head cap with a 10/20 layout. Regression models accounting for independent effects were estimated. The Pattern-pulse mfVEP technique is able to record from patients with advance stage AMD. 25.00",
author = "Yanti Rosli and Goh, {Xin Lin} and Andrew James and Ted Maddess",
year = "2008",
doi = "10.1109/ITSIM.2008.4631854",
language = "English",
isbn = "9781424423286",
volume = "3",
booktitle = "Proceedings - International Symposium on Information Technology 2008, ITSim",

}

TY - GEN

T1 - Neural signal processing of mfVEP responses from AMD patients

AU - Rosli, Yanti

AU - Goh, Xin Lin

AU - James, Andrew

AU - Maddess, Ted

PY - 2008

Y1 - 2008

N2 - Normal healthy subjects and AMD patients were recorded using 64 EEG channels with a computer based acquisition systems using a pattern-pulse mfVEP. A correctly sized head cap (10/20 layout), was placed over the subjects' head. The Fpz electrode holder was placed directly on the 10% nasion-inion mark. The data are simultaneously sampled at 256 Hz per channel, and collected using the ActiveTwo BioSemi data acquisition software.The Active Ag-AgCl electrodes mounted on the head cap was connected to the Biosemi A/D interface box. The stimulus layout was an 84 region per eye cortically-scaled dartboard comprising 12 sectors and 7 concentric rings, subtending a diameter of 23° ; presented dichoptically at 60 Hz frame rate. The 64 electrode channels were held in place with a head cap with a 10/20 layout. Regression models accounting for independent effects were estimated. The Pattern-pulse mfVEP technique is able to record from patients with advance stage AMD. 25.00

AB - Normal healthy subjects and AMD patients were recorded using 64 EEG channels with a computer based acquisition systems using a pattern-pulse mfVEP. A correctly sized head cap (10/20 layout), was placed over the subjects' head. The Fpz electrode holder was placed directly on the 10% nasion-inion mark. The data are simultaneously sampled at 256 Hz per channel, and collected using the ActiveTwo BioSemi data acquisition software.The Active Ag-AgCl electrodes mounted on the head cap was connected to the Biosemi A/D interface box. The stimulus layout was an 84 region per eye cortically-scaled dartboard comprising 12 sectors and 7 concentric rings, subtending a diameter of 23° ; presented dichoptically at 60 Hz frame rate. The 64 electrode channels were held in place with a head cap with a 10/20 layout. Regression models accounting for independent effects were estimated. The Pattern-pulse mfVEP technique is able to record from patients with advance stage AMD. 25.00

UR - http://www.scopus.com/inward/record.url?scp=57349105730&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57349105730&partnerID=8YFLogxK

U2 - 10.1109/ITSIM.2008.4631854

DO - 10.1109/ITSIM.2008.4631854

M3 - Conference contribution

AN - SCOPUS:57349105730

SN - 9781424423286

VL - 3

BT - Proceedings - International Symposium on Information Technology 2008, ITSim

ER -