Abstract

Molecular weight cut-off (MWCO) of commercial and in-house fabricated membranes is obtained at 90% rejection of various types of solutes with different molecular weights (MWs). PEG quantification methods have been favorably employed to determine membranes’ MWCO. Most of the quantification methods utilizing high-end equipment using high performance liquid chromatography (HPLC) and low-end colorimetric method. HPLC method requires an established chromatographic technique using specific diluents, columns and detectors while the most referred colorimetric method requires a few processing steps with concentration up to 7.5 ppm by using UV spectrophotometer. In this work, a newly modified colorimetric method was established to conduct a simple measurement for a membrane’s MWCO. The newly modified method has an excellent linearity for the calibration curves which R2 values are closed to 1 with concentration of up to 150 ppm. A MWCO determination test conducted using different commercial membranes for confirming this newly modified method found that similar MWCO values were obtained as given by the membrane’ manufacturers. In conclusion, this newly modified method is simpler than the formerly used colorimetric method, reliable and applicable for determining the MWCO of membranes ranging from UF to NF at a higher range of PEG concentrations (>150 ppm).

Original languageMalay
Pages (from-to)484-495
Number of pages12
JournalMalaysian Journal of Analytical Sciences
Volume21
Issue number2
DOIs
Publication statusPublished - 1 Apr 2017

Fingerprint

Molecular weight
Membranes
High performance liquid chromatography
Polyethylene glycols
Ultraviolet spectrophotometers
Calibration
Detectors
Processing

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Penentuan berat sekatan molekul bagi membran penurasan tekananmelalui kaedah pengesanan kolorimetri. / Yusoff, Izzati Izni; Rohani, Rosiah; Mohammad, Abdul Wahab.

In: Malaysian Journal of Analytical Sciences, Vol. 21, No. 2, 01.04.2017, p. 484-495.

Research output: Contribution to journalArticle

@article{4e7697571e9e4e68ba6de731baf0de9a,
title = "Penentuan berat sekatan molekul bagi membran penurasan tekananmelalui kaedah pengesanan kolorimetri",
abstract = "Molecular weight cut-off (MWCO) of commercial and in-house fabricated membranes is obtained at 90{\%} rejection of various types of solutes with different molecular weights (MWs). PEG quantification methods have been favorably employed to determine membranes’ MWCO. Most of the quantification methods utilizing high-end equipment using high performance liquid chromatography (HPLC) and low-end colorimetric method. HPLC method requires an established chromatographic technique using specific diluents, columns and detectors while the most referred colorimetric method requires a few processing steps with concentration up to 7.5 ppm by using UV spectrophotometer. In this work, a newly modified colorimetric method was established to conduct a simple measurement for a membrane’s MWCO. The newly modified method has an excellent linearity for the calibration curves which R2 values are closed to 1 with concentration of up to 150 ppm. A MWCO determination test conducted using different commercial membranes for confirming this newly modified method found that similar MWCO values were obtained as given by the membrane’ manufacturers. In conclusion, this newly modified method is simpler than the formerly used colorimetric method, reliable and applicable for determining the MWCO of membranes ranging from UF to NF at a higher range of PEG concentrations (>150 ppm).",
keywords = "Colorimetric, Membrane, Molecular weight cut-off, Polyethylene glycol, Spectrophotometric",
author = "Yusoff, {Izzati Izni} and Rosiah Rohani and Mohammad, {Abdul Wahab}",
year = "2017",
month = "4",
day = "1",
doi = "10.17576/mjas-2017-2102-24",
language = "Malay",
volume = "21",
pages = "484--495",
journal = "Malaysian Journal of Analytical Sciences",
issn = "1394-2506",
publisher = "Faculty of Science and Technology, Universiti Kebangsaan Malaysia",
number = "2",

}

TY - JOUR

T1 - Penentuan berat sekatan molekul bagi membran penurasan tekananmelalui kaedah pengesanan kolorimetri

AU - Yusoff, Izzati Izni

AU - Rohani, Rosiah

AU - Mohammad, Abdul Wahab

PY - 2017/4/1

Y1 - 2017/4/1

N2 - Molecular weight cut-off (MWCO) of commercial and in-house fabricated membranes is obtained at 90% rejection of various types of solutes with different molecular weights (MWs). PEG quantification methods have been favorably employed to determine membranes’ MWCO. Most of the quantification methods utilizing high-end equipment using high performance liquid chromatography (HPLC) and low-end colorimetric method. HPLC method requires an established chromatographic technique using specific diluents, columns and detectors while the most referred colorimetric method requires a few processing steps with concentration up to 7.5 ppm by using UV spectrophotometer. In this work, a newly modified colorimetric method was established to conduct a simple measurement for a membrane’s MWCO. The newly modified method has an excellent linearity for the calibration curves which R2 values are closed to 1 with concentration of up to 150 ppm. A MWCO determination test conducted using different commercial membranes for confirming this newly modified method found that similar MWCO values were obtained as given by the membrane’ manufacturers. In conclusion, this newly modified method is simpler than the formerly used colorimetric method, reliable and applicable for determining the MWCO of membranes ranging from UF to NF at a higher range of PEG concentrations (>150 ppm).

AB - Molecular weight cut-off (MWCO) of commercial and in-house fabricated membranes is obtained at 90% rejection of various types of solutes with different molecular weights (MWs). PEG quantification methods have been favorably employed to determine membranes’ MWCO. Most of the quantification methods utilizing high-end equipment using high performance liquid chromatography (HPLC) and low-end colorimetric method. HPLC method requires an established chromatographic technique using specific diluents, columns and detectors while the most referred colorimetric method requires a few processing steps with concentration up to 7.5 ppm by using UV spectrophotometer. In this work, a newly modified colorimetric method was established to conduct a simple measurement for a membrane’s MWCO. The newly modified method has an excellent linearity for the calibration curves which R2 values are closed to 1 with concentration of up to 150 ppm. A MWCO determination test conducted using different commercial membranes for confirming this newly modified method found that similar MWCO values were obtained as given by the membrane’ manufacturers. In conclusion, this newly modified method is simpler than the formerly used colorimetric method, reliable and applicable for determining the MWCO of membranes ranging from UF to NF at a higher range of PEG concentrations (>150 ppm).

KW - Colorimetric

KW - Membrane

KW - Molecular weight cut-off

KW - Polyethylene glycol

KW - Spectrophotometric

UR - http://www.scopus.com/inward/record.url?scp=85018723576&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85018723576&partnerID=8YFLogxK

U2 - 10.17576/mjas-2017-2102-24

DO - 10.17576/mjas-2017-2102-24

M3 - Article

AN - SCOPUS:85018723576

VL - 21

SP - 484

EP - 495

JO - Malaysian Journal of Analytical Sciences

JF - Malaysian Journal of Analytical Sciences

SN - 1394-2506

IS - 2

ER -