Li-ion battery pack charging process and monitoring in electric vehicle

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper presents the charging process procedure of Li-ion Battery pack for electric vehicle, which is implemented based on constant current and constant voltage (CC-CV) mode. All the informations regarding battery voltage level, state of charge (SOC) during charging and discharging processes, and battery temperature, is displayed on computer via battery management system (BMS). During the charging process, the BMS monitors the voltage balancing in Li-ion battery pack, as well as the cells voltage in each modules. The voltage difference between the highest voltage cell and the lowest voltage cell is very small, which validates the voltage stability and balance in battery pack during the charging and discharging processes.

Original languageEnglish
Title of host publicationApplied Mechanics and Materials
PublisherTrans Tech Publications Ltd
Pages504-509
Number of pages6
Volume663
ISBN (Print)9783038352617
DOIs
Publication statusPublished - 2014
Event2nd International Conference on Recent Advances in Automotive Engineering and Mobility Research, ReCAR 2013 - Kuala Lumpur
Duration: 16 Dec 201318 Dec 2013

Publication series

NameApplied Mechanics and Materials
Volume663
ISSN (Print)16609336
ISSN (Electronic)16627482

Other

Other2nd International Conference on Recent Advances in Automotive Engineering and Mobility Research, ReCAR 2013
CityKuala Lumpur
Period16/12/1318/12/13

Fingerprint

Charging (batteries)
Electric vehicles
Monitoring
Electric potential
Lithium-ion batteries
Voltage control

Keywords

  • Battery management system
  • Charging and discharging
  • Electric vehicle
  • Li-ion battery pack
  • Monitoring

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Yusof, Y., Adnan, M. F. M., Guenther, R., Mohd Zaman, M. H., Ibrahim, A. A., & Ayob, A. (2014). Li-ion battery pack charging process and monitoring in electric vehicle. In Applied Mechanics and Materials (Vol. 663, pp. 504-509). (Applied Mechanics and Materials; Vol. 663). Trans Tech Publications Ltd. https://doi.org/10.4028/www.scientific.net/AMM.663.504

Li-ion battery pack charging process and monitoring in electric vehicle. / Yusof, Yushaizad; Adnan, Mohd Faiz Md; Guenther, Ralf; Mohd Zaman, Mohd Hairi; Ibrahim, Ahmad Asrul; Ayob, Afida.

Applied Mechanics and Materials. Vol. 663 Trans Tech Publications Ltd, 2014. p. 504-509 (Applied Mechanics and Materials; Vol. 663).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yusof, Y, Adnan, MFM, Guenther, R, Mohd Zaman, MH, Ibrahim, AA & Ayob, A 2014, Li-ion battery pack charging process and monitoring in electric vehicle. in Applied Mechanics and Materials. vol. 663, Applied Mechanics and Materials, vol. 663, Trans Tech Publications Ltd, pp. 504-509, 2nd International Conference on Recent Advances in Automotive Engineering and Mobility Research, ReCAR 2013, Kuala Lumpur, 16/12/13. https://doi.org/10.4028/www.scientific.net/AMM.663.504
Yusof Y, Adnan MFM, Guenther R, Mohd Zaman MH, Ibrahim AA, Ayob A. Li-ion battery pack charging process and monitoring in electric vehicle. In Applied Mechanics and Materials. Vol. 663. Trans Tech Publications Ltd. 2014. p. 504-509. (Applied Mechanics and Materials). https://doi.org/10.4028/www.scientific.net/AMM.663.504
Yusof, Yushaizad ; Adnan, Mohd Faiz Md ; Guenther, Ralf ; Mohd Zaman, Mohd Hairi ; Ibrahim, Ahmad Asrul ; Ayob, Afida. / Li-ion battery pack charging process and monitoring in electric vehicle. Applied Mechanics and Materials. Vol. 663 Trans Tech Publications Ltd, 2014. pp. 504-509 (Applied Mechanics and Materials).
@inproceedings{66fab06df6414864b585b2745093f6d1,
title = "Li-ion battery pack charging process and monitoring in electric vehicle",
abstract = "This paper presents the charging process procedure of Li-ion Battery pack for electric vehicle, which is implemented based on constant current and constant voltage (CC-CV) mode. All the informations regarding battery voltage level, state of charge (SOC) during charging and discharging processes, and battery temperature, is displayed on computer via battery management system (BMS). During the charging process, the BMS monitors the voltage balancing in Li-ion battery pack, as well as the cells voltage in each modules. The voltage difference between the highest voltage cell and the lowest voltage cell is very small, which validates the voltage stability and balance in battery pack during the charging and discharging processes.",
keywords = "Battery management system, Charging and discharging, Electric vehicle, Li-ion battery pack, Monitoring",
author = "Yushaizad Yusof and Adnan, {Mohd Faiz Md} and Ralf Guenther and {Mohd Zaman}, {Mohd Hairi} and Ibrahim, {Ahmad Asrul} and Afida Ayob",
year = "2014",
doi = "10.4028/www.scientific.net/AMM.663.504",
language = "English",
isbn = "9783038352617",
volume = "663",
series = "Applied Mechanics and Materials",
publisher = "Trans Tech Publications Ltd",
pages = "504--509",
booktitle = "Applied Mechanics and Materials",

}

TY - GEN

T1 - Li-ion battery pack charging process and monitoring in electric vehicle

AU - Yusof, Yushaizad

AU - Adnan, Mohd Faiz Md

AU - Guenther, Ralf

AU - Mohd Zaman, Mohd Hairi

AU - Ibrahim, Ahmad Asrul

AU - Ayob, Afida

PY - 2014

Y1 - 2014

N2 - This paper presents the charging process procedure of Li-ion Battery pack for electric vehicle, which is implemented based on constant current and constant voltage (CC-CV) mode. All the informations regarding battery voltage level, state of charge (SOC) during charging and discharging processes, and battery temperature, is displayed on computer via battery management system (BMS). During the charging process, the BMS monitors the voltage balancing in Li-ion battery pack, as well as the cells voltage in each modules. The voltage difference between the highest voltage cell and the lowest voltage cell is very small, which validates the voltage stability and balance in battery pack during the charging and discharging processes.

AB - This paper presents the charging process procedure of Li-ion Battery pack for electric vehicle, which is implemented based on constant current and constant voltage (CC-CV) mode. All the informations regarding battery voltage level, state of charge (SOC) during charging and discharging processes, and battery temperature, is displayed on computer via battery management system (BMS). During the charging process, the BMS monitors the voltage balancing in Li-ion battery pack, as well as the cells voltage in each modules. The voltage difference between the highest voltage cell and the lowest voltage cell is very small, which validates the voltage stability and balance in battery pack during the charging and discharging processes.

KW - Battery management system

KW - Charging and discharging

KW - Electric vehicle

KW - Li-ion battery pack

KW - Monitoring

UR - http://www.scopus.com/inward/record.url?scp=84922032092&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84922032092&partnerID=8YFLogxK

U2 - 10.4028/www.scientific.net/AMM.663.504

DO - 10.4028/www.scientific.net/AMM.663.504

M3 - Conference contribution

SN - 9783038352617

VL - 663

T3 - Applied Mechanics and Materials

SP - 504

EP - 509

BT - Applied Mechanics and Materials

PB - Trans Tech Publications Ltd

ER -