Improvement potential and exergy analyses of photovoltaic thermal with and without ∇-absorber collector

Saprizal Hadisaputra, Muhammad Zohri, Hardani, Ahmad Fudholi

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The combination of a solar thermal and photovoltaic system is called photovoltaic thermal system (PVT). The PVT system with and without ∇-absorber has been intended to harvest both hot air and electricity. The hot air that is produced is used in the cooling process of the photovoltaic panel and then to improve the efficiency of the photovoltaic panel. The experimental investigation was conducted at the mass flow rate from 0.0069 kg/s to 0.0491 kg/s and solar radiation of 522 W/m2 and 820 W/m2 in the National University of Malaysia. The using ∇-absorber collector increases exergy and exergy efficiency of PVT system. The improvement potential comparatively upsurges with cumulative the mass flow rate.

Original languageEnglish
Pages (from-to)1792-1798
Number of pages7
JournalInternational Journal of Power Electronics and Drive Systems
Volume9
Issue number4
DOIs
Publication statusPublished - 1 Jan 2018
Externally publishedYes

Fingerprint

Exergy
Flow rate
Air
Solar radiation
Electricity
Cooling
Hot Temperature

Keywords

  • Exergy
  • Improvement potential
  • ∇-collector

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Improvement potential and exergy analyses of photovoltaic thermal with and without ∇-absorber collector. / Hadisaputra, Saprizal; Zohri, Muhammad; Hardani, ; Fudholi, Ahmad.

In: International Journal of Power Electronics and Drive Systems, Vol. 9, No. 4, 01.01.2018, p. 1792-1798.

Research output: Contribution to journalArticle

@article{78da9b2057814cc980b5909acc3f1a40,
title = "Improvement potential and exergy analyses of photovoltaic thermal with and without ∇-absorber collector",
abstract = "The combination of a solar thermal and photovoltaic system is called photovoltaic thermal system (PVT). The PVT system with and without ∇-absorber has been intended to harvest both hot air and electricity. The hot air that is produced is used in the cooling process of the photovoltaic panel and then to improve the efficiency of the photovoltaic panel. The experimental investigation was conducted at the mass flow rate from 0.0069 kg/s to 0.0491 kg/s and solar radiation of 522 W/m2 and 820 W/m2 in the National University of Malaysia. The using ∇-absorber collector increases exergy and exergy efficiency of PVT system. The improvement potential comparatively upsurges with cumulative the mass flow rate.",
keywords = "Exergy, Improvement potential, ∇-collector",
author = "Saprizal Hadisaputra and Muhammad Zohri and Hardani and Ahmad Fudholi",
year = "2018",
month = "1",
day = "1",
doi = "10.11591/ijpeds.v9n4.pp1792-1798",
language = "English",
volume = "9",
pages = "1792--1798",
journal = "International Journal of Power Electronics and Drive Systems",
issn = "2088-8694",
publisher = "Institute of Advanced Engineering and Science (IAES)",
number = "4",

}

TY - JOUR

T1 - Improvement potential and exergy analyses of photovoltaic thermal with and without ∇-absorber collector

AU - Hadisaputra, Saprizal

AU - Zohri, Muhammad

AU - Hardani,

AU - Fudholi, Ahmad

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The combination of a solar thermal and photovoltaic system is called photovoltaic thermal system (PVT). The PVT system with and without ∇-absorber has been intended to harvest both hot air and electricity. The hot air that is produced is used in the cooling process of the photovoltaic panel and then to improve the efficiency of the photovoltaic panel. The experimental investigation was conducted at the mass flow rate from 0.0069 kg/s to 0.0491 kg/s and solar radiation of 522 W/m2 and 820 W/m2 in the National University of Malaysia. The using ∇-absorber collector increases exergy and exergy efficiency of PVT system. The improvement potential comparatively upsurges with cumulative the mass flow rate.

AB - The combination of a solar thermal and photovoltaic system is called photovoltaic thermal system (PVT). The PVT system with and without ∇-absorber has been intended to harvest both hot air and electricity. The hot air that is produced is used in the cooling process of the photovoltaic panel and then to improve the efficiency of the photovoltaic panel. The experimental investigation was conducted at the mass flow rate from 0.0069 kg/s to 0.0491 kg/s and solar radiation of 522 W/m2 and 820 W/m2 in the National University of Malaysia. The using ∇-absorber collector increases exergy and exergy efficiency of PVT system. The improvement potential comparatively upsurges with cumulative the mass flow rate.

KW - Exergy

KW - Improvement potential

KW - ∇-collector

UR - http://www.scopus.com/inward/record.url?scp=85055722765&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055722765&partnerID=8YFLogxK

U2 - 10.11591/ijpeds.v9n4.pp1792-1798

DO - 10.11591/ijpeds.v9n4.pp1792-1798

M3 - Article

AN - SCOPUS:85055722765

VL - 9

SP - 1792

EP - 1798

JO - International Journal of Power Electronics and Drive Systems

JF - International Journal of Power Electronics and Drive Systems

SN - 2088-8694

IS - 4

ER -