Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index

Zetty Adibah Kamaruzzaman, Azah Mohamed

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

This paper analyses the impact of grid-connected photovoltaic (PV) system on static voltage stability using IEEE 30-bus test system. The impact of integrating PV generator into power system was determined. Various penetration PV level and PV generator locations are thoroughly studied using P-V curve and improved voltage stability index (IVSI-index). P-V curve results show that the presence of PV generator improves the loading margin and voltage magnitude of a system. Simulation results of the IVSI-index show that integrating PV generator in low voltage (LV) region improves voltage stability limit though higher PV penetration level has negative impact on the system voltage stability.

Original languageEnglish
Title of host publicationConference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages196-200
Number of pages5
ISBN (Print)9781479972975
DOIs
Publication statusPublished - 17 Mar 2014
Event2014 IEEE International Conference on Power and Energy, PECon 2014 - Kuching, Sarawak, Malaysia
Duration: 1 Dec 20143 Dec 2014

Other

Other2014 IEEE International Conference on Power and Energy, PECon 2014
CountryMalaysia
CityKuching, Sarawak
Period1/12/143/12/14

Fingerprint

Voltage control
Electric potential

Keywords

  • IVSI-index
  • P-V curve
  • solar PV generator
  • static voltage stability

ASJC Scopus subject areas

  • Fuel Technology
  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Kamaruzzaman, Z. A., & Mohamed, A. (2014). Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index. In Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014 (pp. 196-200). [7062440] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/PECON.2014.7062440

Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index. / Kamaruzzaman, Zetty Adibah; Mohamed, Azah.

Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014. Institute of Electrical and Electronics Engineers Inc., 2014. p. 196-200 7062440.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kamaruzzaman, ZA & Mohamed, A 2014, Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index. in Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014., 7062440, Institute of Electrical and Electronics Engineers Inc., pp. 196-200, 2014 IEEE International Conference on Power and Energy, PECon 2014, Kuching, Sarawak, Malaysia, 1/12/14. https://doi.org/10.1109/PECON.2014.7062440
Kamaruzzaman ZA, Mohamed A. Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index. In Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014. Institute of Electrical and Electronics Engineers Inc. 2014. p. 196-200. 7062440 https://doi.org/10.1109/PECON.2014.7062440
Kamaruzzaman, Zetty Adibah ; Mohamed, Azah. / Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index. Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014. Institute of Electrical and Electronics Engineers Inc., 2014. pp. 196-200
@inproceedings{1af3f3defebc4f80a61dd0193f0ed5c7,
title = "Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index",
abstract = "This paper analyses the impact of grid-connected photovoltaic (PV) system on static voltage stability using IEEE 30-bus test system. The impact of integrating PV generator into power system was determined. Various penetration PV level and PV generator locations are thoroughly studied using P-V curve and improved voltage stability index (IVSI-index). P-V curve results show that the presence of PV generator improves the loading margin and voltage magnitude of a system. Simulation results of the IVSI-index show that integrating PV generator in low voltage (LV) region improves voltage stability limit though higher PV penetration level has negative impact on the system voltage stability.",
keywords = "IVSI-index, P-V curve, solar PV generator, static voltage stability",
author = "Kamaruzzaman, {Zetty Adibah} and Azah Mohamed",
year = "2014",
month = "3",
day = "17",
doi = "10.1109/PECON.2014.7062440",
language = "English",
isbn = "9781479972975",
pages = "196--200",
booktitle = "Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Impact of grid-connected photovoltaic generator using P-V curve and improved voltage stability index

AU - Kamaruzzaman, Zetty Adibah

AU - Mohamed, Azah

PY - 2014/3/17

Y1 - 2014/3/17

N2 - This paper analyses the impact of grid-connected photovoltaic (PV) system on static voltage stability using IEEE 30-bus test system. The impact of integrating PV generator into power system was determined. Various penetration PV level and PV generator locations are thoroughly studied using P-V curve and improved voltage stability index (IVSI-index). P-V curve results show that the presence of PV generator improves the loading margin and voltage magnitude of a system. Simulation results of the IVSI-index show that integrating PV generator in low voltage (LV) region improves voltage stability limit though higher PV penetration level has negative impact on the system voltage stability.

AB - This paper analyses the impact of grid-connected photovoltaic (PV) system on static voltage stability using IEEE 30-bus test system. The impact of integrating PV generator into power system was determined. Various penetration PV level and PV generator locations are thoroughly studied using P-V curve and improved voltage stability index (IVSI-index). P-V curve results show that the presence of PV generator improves the loading margin and voltage magnitude of a system. Simulation results of the IVSI-index show that integrating PV generator in low voltage (LV) region improves voltage stability limit though higher PV penetration level has negative impact on the system voltage stability.

KW - IVSI-index

KW - P-V curve

KW - solar PV generator

KW - static voltage stability

UR - http://www.scopus.com/inward/record.url?scp=84946687427&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84946687427&partnerID=8YFLogxK

U2 - 10.1109/PECON.2014.7062440

DO - 10.1109/PECON.2014.7062440

M3 - Conference contribution

AN - SCOPUS:84946687427

SN - 9781479972975

SP - 196

EP - 200

BT - Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014

PB - Institute of Electrical and Electronics Engineers Inc.

ER -