Hybrid coagulation–NF membrane process for brackish water treatment: Effect of antiscalant on water characteristics and membrane fouling

Abdul Wahab Mohammad, A. Benamor, N. Hilal, C. P. Leo, Ang Wei Lun

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Antiscalants have been used to inhibit the formation of scales and reduce the risk of membrane scaling. However, issues such as the increased of biofouling tendency and contradictory observations of organic fouling propensity under the influence of antiscalants have been reported by other researchers. Such observations indicate the need for thorough understanding about the interaction between antiscalants and membrane/foulants in the solution. This study investigated the influence of antiscalant on the water characteristics and the performance of hybrid coagulation–nanofiltration membrane process for brackish water treatment. It was observed that scaling was mitigated with the addition of antiscalants but membrane fouling was exacerbated at higher dosage, probably due to the changes in foulant properties induced by antiscalants. Analysis carried out on the water showed that antiscalants altered the characteristics of the foulants and formed precipitates with calcium/aluminum and iron (from coagulant) ions, which eventually deposited as foulant layer on the membrane surface. This was proven with the existence of phosphorous element on the membrane surface using SEM–EDX. The findings demonstrated how the antiscalants altered the water characteristics and provided insight into the reactivity of antiscalants present in different concentrations, which could be used to interpret the contradicting findings from other researchers.

Original languageEnglish
Pages (from-to)144-150
Number of pages7
JournalDesalination
Volume393
DOIs
Publication statusPublished - 1 Sep 2016

Fingerprint

Membrane fouling
Water treatment
brackish water
fouling
water treatment
membrane
Membranes
Water
water
Biofouling
Coagulants
Fouling
Aluminum
biofouling
Precipitates
Calcium
Iron
Saline Waters
effect
Ions

Keywords

  • Antiscalants
  • Brackish water desalination
  • Hybrid coagulation–membrane process
  • Membrane fouling
  • Scaling
  • Water treatment

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)
  • Materials Science(all)
  • Water Science and Technology
  • Mechanical Engineering

Cite this

Hybrid coagulation–NF membrane process for brackish water treatment : Effect of antiscalant on water characteristics and membrane fouling. / Mohammad, Abdul Wahab; Benamor, A.; Hilal, N.; Leo, C. P.; Wei Lun, Ang.

In: Desalination, Vol. 393, 01.09.2016, p. 144-150.

Research output: Contribution to journalArticle

@article{93e6433c965a496dbeef807948189e49,
title = "Hybrid coagulation–NF membrane process for brackish water treatment: Effect of antiscalant on water characteristics and membrane fouling",
abstract = "Antiscalants have been used to inhibit the formation of scales and reduce the risk of membrane scaling. However, issues such as the increased of biofouling tendency and contradictory observations of organic fouling propensity under the influence of antiscalants have been reported by other researchers. Such observations indicate the need for thorough understanding about the interaction between antiscalants and membrane/foulants in the solution. This study investigated the influence of antiscalant on the water characteristics and the performance of hybrid coagulation–nanofiltration membrane process for brackish water treatment. It was observed that scaling was mitigated with the addition of antiscalants but membrane fouling was exacerbated at higher dosage, probably due to the changes in foulant properties induced by antiscalants. Analysis carried out on the water showed that antiscalants altered the characteristics of the foulants and formed precipitates with calcium/aluminum and iron (from coagulant) ions, which eventually deposited as foulant layer on the membrane surface. This was proven with the existence of phosphorous element on the membrane surface using SEM–EDX. The findings demonstrated how the antiscalants altered the water characteristics and provided insight into the reactivity of antiscalants present in different concentrations, which could be used to interpret the contradicting findings from other researchers.",
keywords = "Antiscalants, Brackish water desalination, Hybrid coagulation–membrane process, Membrane fouling, Scaling, Water treatment",
author = "Mohammad, {Abdul Wahab} and A. Benamor and N. Hilal and Leo, {C. P.} and {Wei Lun}, Ang",
year = "2016",
month = "9",
day = "1",
doi = "10.1016/j.desal.2016.01.010",
language = "English",
volume = "393",
pages = "144--150",
journal = "Desalination",
issn = "0011-9164",
publisher = "Elsevier",

}

TY - JOUR

T1 - Hybrid coagulation–NF membrane process for brackish water treatment

T2 - Effect of antiscalant on water characteristics and membrane fouling

AU - Mohammad, Abdul Wahab

AU - Benamor, A.

AU - Hilal, N.

AU - Leo, C. P.

AU - Wei Lun, Ang

PY - 2016/9/1

Y1 - 2016/9/1

N2 - Antiscalants have been used to inhibit the formation of scales and reduce the risk of membrane scaling. However, issues such as the increased of biofouling tendency and contradictory observations of organic fouling propensity under the influence of antiscalants have been reported by other researchers. Such observations indicate the need for thorough understanding about the interaction between antiscalants and membrane/foulants in the solution. This study investigated the influence of antiscalant on the water characteristics and the performance of hybrid coagulation–nanofiltration membrane process for brackish water treatment. It was observed that scaling was mitigated with the addition of antiscalants but membrane fouling was exacerbated at higher dosage, probably due to the changes in foulant properties induced by antiscalants. Analysis carried out on the water showed that antiscalants altered the characteristics of the foulants and formed precipitates with calcium/aluminum and iron (from coagulant) ions, which eventually deposited as foulant layer on the membrane surface. This was proven with the existence of phosphorous element on the membrane surface using SEM–EDX. The findings demonstrated how the antiscalants altered the water characteristics and provided insight into the reactivity of antiscalants present in different concentrations, which could be used to interpret the contradicting findings from other researchers.

AB - Antiscalants have been used to inhibit the formation of scales and reduce the risk of membrane scaling. However, issues such as the increased of biofouling tendency and contradictory observations of organic fouling propensity under the influence of antiscalants have been reported by other researchers. Such observations indicate the need for thorough understanding about the interaction between antiscalants and membrane/foulants in the solution. This study investigated the influence of antiscalant on the water characteristics and the performance of hybrid coagulation–nanofiltration membrane process for brackish water treatment. It was observed that scaling was mitigated with the addition of antiscalants but membrane fouling was exacerbated at higher dosage, probably due to the changes in foulant properties induced by antiscalants. Analysis carried out on the water showed that antiscalants altered the characteristics of the foulants and formed precipitates with calcium/aluminum and iron (from coagulant) ions, which eventually deposited as foulant layer on the membrane surface. This was proven with the existence of phosphorous element on the membrane surface using SEM–EDX. The findings demonstrated how the antiscalants altered the water characteristics and provided insight into the reactivity of antiscalants present in different concentrations, which could be used to interpret the contradicting findings from other researchers.

KW - Antiscalants

KW - Brackish water desalination

KW - Hybrid coagulation–membrane process

KW - Membrane fouling

KW - Scaling

KW - Water treatment

UR - http://www.scopus.com/inward/record.url?scp=85009710083&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85009710083&partnerID=8YFLogxK

U2 - 10.1016/j.desal.2016.01.010

DO - 10.1016/j.desal.2016.01.010

M3 - Article

AN - SCOPUS:85009710083

VL - 393

SP - 144

EP - 150

JO - Desalination

JF - Desalination

SN - 0011-9164

ER -