Abstract

This paper proposes a new harmonic current detection method using an average DC voltage and current of voltage source nonlinear load instead of a typical load current and a source voltage. By using a MATLAB Simulink tool, a model of single-phase AC system connected to a full bridge diode rectifier with capacitive load is designed. A step by step simulation results towards a generation of sinusoidal reference current and filtered reference current are presented and analysed. As a conclusion, the proposed harmonic detection method successfully achieved its objective to generate the reference current signals for the single-phase active power filter circuit.

Original languageEnglish
Title of host publication2019 7th International Conference on Smart Computing and Communications, ICSCC 2019
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781728115573
DOIs
Publication statusPublished - Jun 2019
Event7th International Conference on Smart Computing and Communications, ICSCC 2019 - Miri, Malaysia
Duration: 28 Jun 201930 Jun 2019

Publication series

Name2019 7th International Conference on Smart Computing and Communications, ICSCC 2019

Conference

Conference7th International Conference on Smart Computing and Communications, ICSCC 2019
CountryMalaysia
CityMiri
Period28/6/1930/6/19

Fingerprint

Electric potential
MATLAB
Diodes
Networks (circuits)

Keywords

  • average DC voltage
  • detection method
  • harmonic
  • nonlinear load
  • reference current

ASJC Scopus subject areas

  • Artificial Intelligence
  • Computer Networks and Communications
  • Hardware and Architecture
  • Safety, Risk, Reliability and Quality

Cite this

Yusof, Y., Za'Im, R., Ayob, A., Muad, A. M., & Mohamed, R. (2019). Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current. In 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019 [8843641] (2019 7th International Conference on Smart Computing and Communications, ICSCC 2019). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICSCC.2019.8843641

Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current. / Yusof, Yushaizad; Za'Im, Radin; Ayob, Afida; Muad, Anuar Mikdad; Mohamed, Ramizi.

2019 7th International Conference on Smart Computing and Communications, ICSCC 2019. Institute of Electrical and Electronics Engineers Inc., 2019. 8843641 (2019 7th International Conference on Smart Computing and Communications, ICSCC 2019).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yusof, Y, Za'Im, R, Ayob, A, Muad, AM & Mohamed, R 2019, Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current. in 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019., 8843641, 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019, Institute of Electrical and Electronics Engineers Inc., 7th International Conference on Smart Computing and Communications, ICSCC 2019, Miri, Malaysia, 28/6/19. https://doi.org/10.1109/ICSCC.2019.8843641
Yusof Y, Za'Im R, Ayob A, Muad AM, Mohamed R. Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current. In 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019. Institute of Electrical and Electronics Engineers Inc. 2019. 8843641. (2019 7th International Conference on Smart Computing and Communications, ICSCC 2019). https://doi.org/10.1109/ICSCC.2019.8843641
Yusof, Yushaizad ; Za'Im, Radin ; Ayob, Afida ; Muad, Anuar Mikdad ; Mohamed, Ramizi. / Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current. 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019. Institute of Electrical and Electronics Engineers Inc., 2019. (2019 7th International Conference on Smart Computing and Communications, ICSCC 2019).
@inproceedings{c63e9215317a409290e73ca226e4ec75,
title = "Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current",
abstract = "This paper proposes a new harmonic current detection method using an average DC voltage and current of voltage source nonlinear load instead of a typical load current and a source voltage. By using a MATLAB Simulink tool, a model of single-phase AC system connected to a full bridge diode rectifier with capacitive load is designed. A step by step simulation results towards a generation of sinusoidal reference current and filtered reference current are presented and analysed. As a conclusion, the proposed harmonic detection method successfully achieved its objective to generate the reference current signals for the single-phase active power filter circuit.",
keywords = "average DC voltage, detection method, harmonic, nonlinear load, reference current",
author = "Yushaizad Yusof and Radin Za'Im and Afida Ayob and Muad, {Anuar Mikdad} and Ramizi Mohamed",
year = "2019",
month = "6",
doi = "10.1109/ICSCC.2019.8843641",
language = "English",
series = "2019 7th International Conference on Smart Computing and Communications, ICSCC 2019",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
booktitle = "2019 7th International Conference on Smart Computing and Communications, ICSCC 2019",

}

TY - GEN

T1 - Harmonic Current Detection Method Using Nonlinear Load's DC Output Voltage and Current

AU - Yusof, Yushaizad

AU - Za'Im, Radin

AU - Ayob, Afida

AU - Muad, Anuar Mikdad

AU - Mohamed, Ramizi

PY - 2019/6

Y1 - 2019/6

N2 - This paper proposes a new harmonic current detection method using an average DC voltage and current of voltage source nonlinear load instead of a typical load current and a source voltage. By using a MATLAB Simulink tool, a model of single-phase AC system connected to a full bridge diode rectifier with capacitive load is designed. A step by step simulation results towards a generation of sinusoidal reference current and filtered reference current are presented and analysed. As a conclusion, the proposed harmonic detection method successfully achieved its objective to generate the reference current signals for the single-phase active power filter circuit.

AB - This paper proposes a new harmonic current detection method using an average DC voltage and current of voltage source nonlinear load instead of a typical load current and a source voltage. By using a MATLAB Simulink tool, a model of single-phase AC system connected to a full bridge diode rectifier with capacitive load is designed. A step by step simulation results towards a generation of sinusoidal reference current and filtered reference current are presented and analysed. As a conclusion, the proposed harmonic detection method successfully achieved its objective to generate the reference current signals for the single-phase active power filter circuit.

KW - average DC voltage

KW - detection method

KW - harmonic

KW - nonlinear load

KW - reference current

UR - http://www.scopus.com/inward/record.url?scp=85073244508&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85073244508&partnerID=8YFLogxK

U2 - 10.1109/ICSCC.2019.8843641

DO - 10.1109/ICSCC.2019.8843641

M3 - Conference contribution

AN - SCOPUS:85073244508

T3 - 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019

BT - 2019 7th International Conference on Smart Computing and Communications, ICSCC 2019

PB - Institute of Electrical and Electronics Engineers Inc.

ER -