Abstract

The corrosion of an aluminum alloy (Al2024) and copper in 1. 0M HCl solution was investigated at 30, 40, 50 and 60 °C using open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization (PDP) measurements. The galvanic corrosion of Al2024 and copper was studied using the zero resistance ammeter (ZRA) method. Galvanic current densities (I g) and galvanic potential (E g) were measured at 30 °C in 1. 0M HCl solution. Thermodynamic parameters, such as activation energy (E a), enthalpy of activation (ΔH a) and entropy of activation (ΔS a), were calculated and discussed. The results indicated that the corrosion rates of both Al2024 and copper increased with temperature. The ZRA results demonstrated that Al2024 is a sacrificial anode in 1. 0M HCl solution when coupled with copper.

Original languageEnglish
Pages (from-to)818-822
Number of pages5
JournalKorean Journal of Chemical Engineering
Volume29
Issue number6
DOIs
Publication statusPublished - Jun 2012

Fingerprint

Hydrochloric Acid
Hydrochloric acid
Copper
Aluminum alloys
Ammeters
Corrosion
Chemical activation
Potentiodynamic polarization
Corrosion rate
Electrochemical impedance spectroscopy
Enthalpy
Anodes
Current density
Entropy
Activation energy
Thermodynamics
Networks (circuits)
Temperature

Keywords

  • Aluminum
  • Copper
  • Galvanic Corrosion
  • Thermodynamic Parameters
  • ZRA

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

Galvanic corrosion of aluminum alloy (Al2024) and copper in 1.0M hydrochloric acid solution. / Musa, Ahmed Y.; Mohamad, Abu Bakar; Al-Amiery, Ahmed A.; Tien, Lim Tien.

In: Korean Journal of Chemical Engineering, Vol. 29, No. 6, 06.2012, p. 818-822.

Research output: Contribution to journalArticle

Musa, Ahmed Y. ; Mohamad, Abu Bakar ; Al-Amiery, Ahmed A. ; Tien, Lim Tien. / Galvanic corrosion of aluminum alloy (Al2024) and copper in 1.0M hydrochloric acid solution. In: Korean Journal of Chemical Engineering. 2012 ; Vol. 29, No. 6. pp. 818-822.
@article{fe8f067a1742419eb320832619ba1ad8,
title = "Galvanic corrosion of aluminum alloy (Al2024) and copper in 1.0M hydrochloric acid solution",
abstract = "The corrosion of an aluminum alloy (Al2024) and copper in 1. 0M HCl solution was investigated at 30, 40, 50 and 60 °C using open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization (PDP) measurements. The galvanic corrosion of Al2024 and copper was studied using the zero resistance ammeter (ZRA) method. Galvanic current densities (I g) and galvanic potential (E g) were measured at 30 °C in 1. 0M HCl solution. Thermodynamic parameters, such as activation energy (E a), enthalpy of activation (ΔH a) and entropy of activation (ΔS a), were calculated and discussed. The results indicated that the corrosion rates of both Al2024 and copper increased with temperature. The ZRA results demonstrated that Al2024 is a sacrificial anode in 1. 0M HCl solution when coupled with copper.",
keywords = "Aluminum, Copper, Galvanic Corrosion, Thermodynamic Parameters, ZRA",
author = "Musa, {Ahmed Y.} and Mohamad, {Abu Bakar} and Al-Amiery, {Ahmed A.} and Tien, {Lim Tien}",
year = "2012",
month = "6",
doi = "10.1007/s11814-011-0233-z",
language = "English",
volume = "29",
pages = "818--822",
journal = "Korean Journal of Chemical Engineering",
issn = "0256-1115",
publisher = "Springer New York",
number = "6",

}

TY - JOUR

T1 - Galvanic corrosion of aluminum alloy (Al2024) and copper in 1.0M hydrochloric acid solution

AU - Musa, Ahmed Y.

AU - Mohamad, Abu Bakar

AU - Al-Amiery, Ahmed A.

AU - Tien, Lim Tien

PY - 2012/6

Y1 - 2012/6

N2 - The corrosion of an aluminum alloy (Al2024) and copper in 1. 0M HCl solution was investigated at 30, 40, 50 and 60 °C using open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization (PDP) measurements. The galvanic corrosion of Al2024 and copper was studied using the zero resistance ammeter (ZRA) method. Galvanic current densities (I g) and galvanic potential (E g) were measured at 30 °C in 1. 0M HCl solution. Thermodynamic parameters, such as activation energy (E a), enthalpy of activation (ΔH a) and entropy of activation (ΔS a), were calculated and discussed. The results indicated that the corrosion rates of both Al2024 and copper increased with temperature. The ZRA results demonstrated that Al2024 is a sacrificial anode in 1. 0M HCl solution when coupled with copper.

AB - The corrosion of an aluminum alloy (Al2024) and copper in 1. 0M HCl solution was investigated at 30, 40, 50 and 60 °C using open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization (PDP) measurements. The galvanic corrosion of Al2024 and copper was studied using the zero resistance ammeter (ZRA) method. Galvanic current densities (I g) and galvanic potential (E g) were measured at 30 °C in 1. 0M HCl solution. Thermodynamic parameters, such as activation energy (E a), enthalpy of activation (ΔH a) and entropy of activation (ΔS a), were calculated and discussed. The results indicated that the corrosion rates of both Al2024 and copper increased with temperature. The ZRA results demonstrated that Al2024 is a sacrificial anode in 1. 0M HCl solution when coupled with copper.

KW - Aluminum

KW - Copper

KW - Galvanic Corrosion

KW - Thermodynamic Parameters

KW - ZRA

UR - http://www.scopus.com/inward/record.url?scp=84862119360&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84862119360&partnerID=8YFLogxK

U2 - 10.1007/s11814-011-0233-z

DO - 10.1007/s11814-011-0233-z

M3 - Article

VL - 29

SP - 818

EP - 822

JO - Korean Journal of Chemical Engineering

JF - Korean Journal of Chemical Engineering

SN - 0256-1115

IS - 6

ER -