Externally stiffened I-beam to box-column connections

N. E. Shanmugam

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance of T-stiffeners was found to be better than that of the other types. A simple design procedure has been proposed for T-stiffeners.

Original languageEnglish
Title of host publicationProc Struct Congr 94
Place of PublicationNew York, NY, United States
PublisherPubl by ASCE
Pages719-724
Number of pages6
ISBN (Print)087262952X
Publication statusPublished - 1994
Externally publishedYes
EventProceedings of the Structures Congress '94 - Atlanta, GA, USA
Duration: 24 Apr 199428 Apr 1994

Other

OtherProceedings of the Structures Congress '94
CityAtlanta, GA, USA
Period24/4/9428/4/94

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Shanmugam, N. E. (1994). Externally stiffened I-beam to box-column connections. In Proc Struct Congr 94 (pp. 719-724). New York, NY, United States: Publ by ASCE.

Externally stiffened I-beam to box-column connections. / Shanmugam, N. E.

Proc Struct Congr 94. New York, NY, United States : Publ by ASCE, 1994. p. 719-724.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Shanmugam, NE 1994, Externally stiffened I-beam to box-column connections. in Proc Struct Congr 94. Publ by ASCE, New York, NY, United States, pp. 719-724, Proceedings of the Structures Congress '94, Atlanta, GA, USA, 24/4/94.
Shanmugam NE. Externally stiffened I-beam to box-column connections. In Proc Struct Congr 94. New York, NY, United States: Publ by ASCE. 1994. p. 719-724
Shanmugam, N. E. / Externally stiffened I-beam to box-column connections. Proc Struct Congr 94. New York, NY, United States : Publ by ASCE, 1994. pp. 719-724
@inproceedings{b9442f5b5e5d482e9964dcfb74763480,
title = "Externally stiffened I-beam to box-column connections",
abstract = "This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance of T-stiffeners was found to be better than that of the other types. A simple design procedure has been proposed for T-stiffeners.",
author = "Shanmugam, {N. E.}",
year = "1994",
language = "English",
isbn = "087262952X",
pages = "719--724",
booktitle = "Proc Struct Congr 94",
publisher = "Publ by ASCE",

}

TY - GEN

T1 - Externally stiffened I-beam to box-column connections

AU - Shanmugam, N. E.

PY - 1994

Y1 - 1994

N2 - This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance of T-stiffeners was found to be better than that of the other types. A simple design procedure has been proposed for T-stiffeners.

AB - This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance of T-stiffeners was found to be better than that of the other types. A simple design procedure has been proposed for T-stiffeners.

UR - http://www.scopus.com/inward/record.url?scp=0027929224&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027929224&partnerID=8YFLogxK

M3 - Conference contribution

SN - 087262952X

SP - 719

EP - 724

BT - Proc Struct Congr 94

PB - Publ by ASCE

CY - New York, NY, United States

ER -