Experimental study on the efficiency of tuned liquid dampers for vibration mitigation of a vertically irregular structure

Ali Pabarja, Moahmmadreza Vafaei, Sophia C. Alih, Mohd. Yazmil Md. Yatim, Siti Aminah Osman

Research output: Contribution to journalArticle

Abstract

This paper investigates the efficiency of Tuned Liquid Dampers (TLDs) in mitigating dynamic responses of vertically irregular structures. For this purpose, a three-story steel structure was specifically designed and subjected to free and forced vibration tests. In addition, the dynamic responses of eight structure-TLD systems were investigated through three cases. In the first and second cases, TLDs were tuned to the first and second natural frequencies of the steel structure and they were installed on each floor separately. In the third case, which was referred to as the combined case, two TLDs that were tuned to the first and second natural frequencies were first placed simultaneously on the third floor and then separately on the third and second floors. The results indicated that the installation of the combined TLDs on the third floor reduced the peak acceleration and displacement responses of the third floor more than the other cases. It was also observed that, in all the studied cases, the peak displacement response of the third floor was significantly increased when the structure-TLD systems were excited at the second resonance frequency. In addition, at the second resonance frequency, the TLD which was tuned to the first natural frequency and installed at the third floor increased the peak acceleration responses of all floors. It was concluded that, unlike the case in regular structures, a TLD which is tuned to the first natural frequency and installed at the highest level of an irregular structure may not satisfactorily mitigate the structural response of all floors.

LanguageEnglish
Pages84-105
Number of pages22
JournalMechanical Systems and Signal Processing
Volume114
DOIs
Publication statusPublished - 1 Jan 2019

Fingerprint

Liquids
Natural frequencies
Steel structures
Dynamic response

Keywords

  • Dynamic responses
  • Forced vibration
  • Free vibration
  • Irregular structure
  • Resonance frequency
  • Tuned liquid damper

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Signal Processing
  • Civil and Structural Engineering
  • Aerospace Engineering
  • Mechanical Engineering
  • Computer Science Applications

Cite this

Experimental study on the efficiency of tuned liquid dampers for vibration mitigation of a vertically irregular structure. / Pabarja, Ali; Vafaei, Moahmmadreza; C. Alih, Sophia; Md. Yatim, Mohd. Yazmil; Osman, Siti Aminah.

In: Mechanical Systems and Signal Processing, Vol. 114, 01.01.2019, p. 84-105.

Research output: Contribution to journalArticle

@article{7068a452889b4595a647fa695787525d,
title = "Experimental study on the efficiency of tuned liquid dampers for vibration mitigation of a vertically irregular structure",
abstract = "This paper investigates the efficiency of Tuned Liquid Dampers (TLDs) in mitigating dynamic responses of vertically irregular structures. For this purpose, a three-story steel structure was specifically designed and subjected to free and forced vibration tests. In addition, the dynamic responses of eight structure-TLD systems were investigated through three cases. In the first and second cases, TLDs were tuned to the first and second natural frequencies of the steel structure and they were installed on each floor separately. In the third case, which was referred to as the combined case, two TLDs that were tuned to the first and second natural frequencies were first placed simultaneously on the third floor and then separately on the third and second floors. The results indicated that the installation of the combined TLDs on the third floor reduced the peak acceleration and displacement responses of the third floor more than the other cases. It was also observed that, in all the studied cases, the peak displacement response of the third floor was significantly increased when the structure-TLD systems were excited at the second resonance frequency. In addition, at the second resonance frequency, the TLD which was tuned to the first natural frequency and installed at the third floor increased the peak acceleration responses of all floors. It was concluded that, unlike the case in regular structures, a TLD which is tuned to the first natural frequency and installed at the highest level of an irregular structure may not satisfactorily mitigate the structural response of all floors.",
keywords = "Dynamic responses, Forced vibration, Free vibration, Irregular structure, Resonance frequency, Tuned liquid damper",
author = "Ali Pabarja and Moahmmadreza Vafaei and {C. Alih}, Sophia and {Md. Yatim}, {Mohd. Yazmil} and Osman, {Siti Aminah}",
year = "2019",
month = "1",
day = "1",
doi = "10.1016/j.ymssp.2018.05.008",
language = "English",
volume = "114",
pages = "84--105",
journal = "Mechanical Systems and Signal Processing",
issn = "0888-3270",
publisher = "Academic Press Inc.",

}

TY - JOUR

T1 - Experimental study on the efficiency of tuned liquid dampers for vibration mitigation of a vertically irregular structure

AU - Pabarja, Ali

AU - Vafaei, Moahmmadreza

AU - C. Alih, Sophia

AU - Md. Yatim, Mohd. Yazmil

AU - Osman, Siti Aminah

PY - 2019/1/1

Y1 - 2019/1/1

N2 - This paper investigates the efficiency of Tuned Liquid Dampers (TLDs) in mitigating dynamic responses of vertically irregular structures. For this purpose, a three-story steel structure was specifically designed and subjected to free and forced vibration tests. In addition, the dynamic responses of eight structure-TLD systems were investigated through three cases. In the first and second cases, TLDs were tuned to the first and second natural frequencies of the steel structure and they were installed on each floor separately. In the third case, which was referred to as the combined case, two TLDs that were tuned to the first and second natural frequencies were first placed simultaneously on the third floor and then separately on the third and second floors. The results indicated that the installation of the combined TLDs on the third floor reduced the peak acceleration and displacement responses of the third floor more than the other cases. It was also observed that, in all the studied cases, the peak displacement response of the third floor was significantly increased when the structure-TLD systems were excited at the second resonance frequency. In addition, at the second resonance frequency, the TLD which was tuned to the first natural frequency and installed at the third floor increased the peak acceleration responses of all floors. It was concluded that, unlike the case in regular structures, a TLD which is tuned to the first natural frequency and installed at the highest level of an irregular structure may not satisfactorily mitigate the structural response of all floors.

AB - This paper investigates the efficiency of Tuned Liquid Dampers (TLDs) in mitigating dynamic responses of vertically irregular structures. For this purpose, a three-story steel structure was specifically designed and subjected to free and forced vibration tests. In addition, the dynamic responses of eight structure-TLD systems were investigated through three cases. In the first and second cases, TLDs were tuned to the first and second natural frequencies of the steel structure and they were installed on each floor separately. In the third case, which was referred to as the combined case, two TLDs that were tuned to the first and second natural frequencies were first placed simultaneously on the third floor and then separately on the third and second floors. The results indicated that the installation of the combined TLDs on the third floor reduced the peak acceleration and displacement responses of the third floor more than the other cases. It was also observed that, in all the studied cases, the peak displacement response of the third floor was significantly increased when the structure-TLD systems were excited at the second resonance frequency. In addition, at the second resonance frequency, the TLD which was tuned to the first natural frequency and installed at the third floor increased the peak acceleration responses of all floors. It was concluded that, unlike the case in regular structures, a TLD which is tuned to the first natural frequency and installed at the highest level of an irregular structure may not satisfactorily mitigate the structural response of all floors.

KW - Dynamic responses

KW - Forced vibration

KW - Free vibration

KW - Irregular structure

KW - Resonance frequency

KW - Tuned liquid damper

UR - http://www.scopus.com/inward/record.url?scp=85047011605&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85047011605&partnerID=8YFLogxK

U2 - 10.1016/j.ymssp.2018.05.008

DO - 10.1016/j.ymssp.2018.05.008

M3 - Article

VL - 114

SP - 84

EP - 105

JO - Mechanical Systems and Signal Processing

T2 - Mechanical Systems and Signal Processing

JF - Mechanical Systems and Signal Processing

SN - 0888-3270