This research paper describes the investigation of new innovative form of lightweight composite known as Profiled Steel Sheeting Dry Board (PSSDB) wall panel system. Profiled Steel Sheeting Dry Board (PSSDB) is categorized as Industrialized Building System where paneling system has been developed to substitute the traditional structure of brick wall. The proposed system is a novel form of double and single sheathed composite panel. It consists of dry board and profiled steel sheet for middle core, attached by screws at both surfaces forming the composite action. This paper present the experimental results of twelve full scaled samples of PSSDB wall panel by using Cliplock 610 and PEVA45 as profiled steel sheet and PrimaFlex dry board for surface sheathed. All 12 wall panel samples have been tested under axial load until failure. From the experiment, it was found that the maximum load capacity of PSSDB wall panel can withstand is 1329kN with PEVA45 at screw spacing of 200 mm. While for the wall panel assembled using Cliplock 610, the maximum load is 612kN. The study shows that the new PSSDB wall panel system has a great potential to be used as a load bearing under axial load and expected to have a confidence for structural system in future construction.

Original languageEnglish
Title of host publicationKey Engineering Materials
Pages421-426
Number of pages6
Volume594-595
DOIs
Publication statusPublished - 2014
Event2013 International Conference on Advanced Materials Engineering and Technology, ICAMET 2013 - Bandung
Duration: 28 Nov 201329 Nov 2013

Publication series

NameKey Engineering Materials
Volume594-595
ISSN (Print)10139826

Other

Other2013 International Conference on Advanced Materials Engineering and Technology, ICAMET 2013
CityBandung
Period28/11/1329/11/13

Fingerprint

Steel
Steel sheet
Axial loads
Composite materials
Bearings (structural)
Brick
Loads (forces)
Experiments

Keywords

  • Buckling
  • Dry board
  • Profiled steel sheet
  • Wall panel

ASJC Scopus subject areas

  • Materials Science(all)
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

Majid, M. A., & Wan Badaruzzaman, W. H. (2014). Experimental evaluation of profiled steel sheet dry board wall panel system. In Key Engineering Materials (Vol. 594-595, pp. 421-426). (Key Engineering Materials; Vol. 594-595). https://doi.org/10.4028/www.scientific.net/KEM.594-595.421

Experimental evaluation of profiled steel sheet dry board wall panel system. / Majid, Masni A.; Wan Badaruzzaman, Wan Hamidon.

Key Engineering Materials. Vol. 594-595 2014. p. 421-426 (Key Engineering Materials; Vol. 594-595).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Majid, MA & Wan Badaruzzaman, WH 2014, Experimental evaluation of profiled steel sheet dry board wall panel system. in Key Engineering Materials. vol. 594-595, Key Engineering Materials, vol. 594-595, pp. 421-426, 2013 International Conference on Advanced Materials Engineering and Technology, ICAMET 2013, Bandung, 28/11/13. https://doi.org/10.4028/www.scientific.net/KEM.594-595.421
Majid MA, Wan Badaruzzaman WH. Experimental evaluation of profiled steel sheet dry board wall panel system. In Key Engineering Materials. Vol. 594-595. 2014. p. 421-426. (Key Engineering Materials). https://doi.org/10.4028/www.scientific.net/KEM.594-595.421
Majid, Masni A. ; Wan Badaruzzaman, Wan Hamidon. / Experimental evaluation of profiled steel sheet dry board wall panel system. Key Engineering Materials. Vol. 594-595 2014. pp. 421-426 (Key Engineering Materials).
@inproceedings{b9b749cbf3e140e5882ccb19ef93b3c7,
title = "Experimental evaluation of profiled steel sheet dry board wall panel system",
abstract = "This research paper describes the investigation of new innovative form of lightweight composite known as Profiled Steel Sheeting Dry Board (PSSDB) wall panel system. Profiled Steel Sheeting Dry Board (PSSDB) is categorized as Industrialized Building System where paneling system has been developed to substitute the traditional structure of brick wall. The proposed system is a novel form of double and single sheathed composite panel. It consists of dry board and profiled steel sheet for middle core, attached by screws at both surfaces forming the composite action. This paper present the experimental results of twelve full scaled samples of PSSDB wall panel by using Cliplock 610 and PEVA45 as profiled steel sheet and PrimaFlex dry board for surface sheathed. All 12 wall panel samples have been tested under axial load until failure. From the experiment, it was found that the maximum load capacity of PSSDB wall panel can withstand is 1329kN with PEVA45 at screw spacing of 200 mm. While for the wall panel assembled using Cliplock 610, the maximum load is 612kN. The study shows that the new PSSDB wall panel system has a great potential to be used as a load bearing under axial load and expected to have a confidence for structural system in future construction.",
keywords = "Buckling, Dry board, Profiled steel sheet, Wall panel",
author = "Majid, {Masni A.} and {Wan Badaruzzaman}, {Wan Hamidon}",
year = "2014",
doi = "10.4028/www.scientific.net/KEM.594-595.421",
language = "English",
isbn = "9783037859377",
volume = "594-595",
series = "Key Engineering Materials",
pages = "421--426",
booktitle = "Key Engineering Materials",

}

TY - GEN

T1 - Experimental evaluation of profiled steel sheet dry board wall panel system

AU - Majid, Masni A.

AU - Wan Badaruzzaman, Wan Hamidon

PY - 2014

Y1 - 2014

N2 - This research paper describes the investigation of new innovative form of lightweight composite known as Profiled Steel Sheeting Dry Board (PSSDB) wall panel system. Profiled Steel Sheeting Dry Board (PSSDB) is categorized as Industrialized Building System where paneling system has been developed to substitute the traditional structure of brick wall. The proposed system is a novel form of double and single sheathed composite panel. It consists of dry board and profiled steel sheet for middle core, attached by screws at both surfaces forming the composite action. This paper present the experimental results of twelve full scaled samples of PSSDB wall panel by using Cliplock 610 and PEVA45 as profiled steel sheet and PrimaFlex dry board for surface sheathed. All 12 wall panel samples have been tested under axial load until failure. From the experiment, it was found that the maximum load capacity of PSSDB wall panel can withstand is 1329kN with PEVA45 at screw spacing of 200 mm. While for the wall panel assembled using Cliplock 610, the maximum load is 612kN. The study shows that the new PSSDB wall panel system has a great potential to be used as a load bearing under axial load and expected to have a confidence for structural system in future construction.

AB - This research paper describes the investigation of new innovative form of lightweight composite known as Profiled Steel Sheeting Dry Board (PSSDB) wall panel system. Profiled Steel Sheeting Dry Board (PSSDB) is categorized as Industrialized Building System where paneling system has been developed to substitute the traditional structure of brick wall. The proposed system is a novel form of double and single sheathed composite panel. It consists of dry board and profiled steel sheet for middle core, attached by screws at both surfaces forming the composite action. This paper present the experimental results of twelve full scaled samples of PSSDB wall panel by using Cliplock 610 and PEVA45 as profiled steel sheet and PrimaFlex dry board for surface sheathed. All 12 wall panel samples have been tested under axial load until failure. From the experiment, it was found that the maximum load capacity of PSSDB wall panel can withstand is 1329kN with PEVA45 at screw spacing of 200 mm. While for the wall panel assembled using Cliplock 610, the maximum load is 612kN. The study shows that the new PSSDB wall panel system has a great potential to be used as a load bearing under axial load and expected to have a confidence for structural system in future construction.

KW - Buckling

KW - Dry board

KW - Profiled steel sheet

KW - Wall panel

UR - http://www.scopus.com/inward/record.url?scp=84891890427&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84891890427&partnerID=8YFLogxK

U2 - 10.4028/www.scientific.net/KEM.594-595.421

DO - 10.4028/www.scientific.net/KEM.594-595.421

M3 - Conference contribution

AN - SCOPUS:84891890427

SN - 9783037859377

VL - 594-595

T3 - Key Engineering Materials

SP - 421

EP - 426

BT - Key Engineering Materials