Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia

M. K A Karim, S. Hashim, Akmal Sabarudin, D. A. Bradley, N. A. Bahruddin

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0±1.3 to 67.7±3.4 mGy, 300.2±135.4 to 1174.2±79.9 mGy.cm and 1.5±0.2 to 11.7±6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored.

Original languageEnglish
Pages (from-to)567-573
Number of pages7
JournalSains Malaysiana
Volume45
Issue number4
Publication statusPublished - 1 Apr 2016
Externally publishedYes

Fingerprint

Malaysia
Radiation
Neoplasms
Abdomen
Germany
Publications
Thorax
Software
Brain

Keywords

  • Ct scan
  • Effective dose
  • Organ equivalent dose
  • Risk assessment

ASJC Scopus subject areas

  • General

Cite this

Karim, M. K. A., Hashim, S., Sabarudin, A., Bradley, D. A., & Bahruddin, N. A. (2016). Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia. Sains Malaysiana, 45(4), 567-573.

Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia. / Karim, M. K A; Hashim, S.; Sabarudin, Akmal; Bradley, D. A.; Bahruddin, N. A.

In: Sains Malaysiana, Vol. 45, No. 4, 01.04.2016, p. 567-573.

Research output: Contribution to journalArticle

Karim, MKA, Hashim, S, Sabarudin, A, Bradley, DA & Bahruddin, NA 2016, 'Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia', Sains Malaysiana, vol. 45, no. 4, pp. 567-573.
Karim MKA, Hashim S, Sabarudin A, Bradley DA, Bahruddin NA. Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia. Sains Malaysiana. 2016 Apr 1;45(4):567-573.
Karim, M. K A ; Hashim, S. ; Sabarudin, Akmal ; Bradley, D. A. ; Bahruddin, N. A. / Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia. In: Sains Malaysiana. 2016 ; Vol. 45, No. 4. pp. 567-573.
@article{a084789fee304e2fbc9c35849c17e06b,
title = "Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia",
abstract = "In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0±1.3 to 67.7±3.4 mGy, 300.2±135.4 to 1174.2±79.9 mGy.cm and 1.5±0.2 to 11.7±6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored.",
keywords = "Ct scan, Effective dose, Organ equivalent dose, Risk assessment",
author = "Karim, {M. K A} and S. Hashim and Akmal Sabarudin and Bradley, {D. A.} and Bahruddin, {N. A.}",
year = "2016",
month = "4",
day = "1",
language = "English",
volume = "45",
pages = "567--573",
journal = "Sains Malaysiana",
issn = "0126-6039",
publisher = "Penerbit Universiti Kebangsaan Malaysia",
number = "4",

}

TY - JOUR

T1 - Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia

AU - Karim, M. K A

AU - Hashim, S.

AU - Sabarudin, Akmal

AU - Bradley, D. A.

AU - Bahruddin, N. A.

PY - 2016/4/1

Y1 - 2016/4/1

N2 - In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0±1.3 to 67.7±3.4 mGy, 300.2±135.4 to 1174.2±79.9 mGy.cm and 1.5±0.2 to 11.7±6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored.

AB - In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0±1.3 to 67.7±3.4 mGy, 300.2±135.4 to 1174.2±79.9 mGy.cm and 1.5±0.2 to 11.7±6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored.

KW - Ct scan

KW - Effective dose

KW - Organ equivalent dose

KW - Risk assessment

UR - http://www.scopus.com/inward/record.url?scp=84966661772&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84966661772&partnerID=8YFLogxK

M3 - Article

VL - 45

SP - 567

EP - 573

JO - Sains Malaysiana

JF - Sains Malaysiana

SN - 0126-6039

IS - 4

ER -