Abstract

Combining the ejector-flash tank with the single stage absorption cycle using NH<inf>3</inf>/H<inf>2</inf>O as the working fluid has shown potential improvement in the COP. In our previous work, ejector efficiency faced some limitation due to the presence of booster at refrigerant streamline side. Removing the booster from the refrigerant streamline side and allowing the secondary flow of the ejector to work only under the intermediate pressure of the flash tank could optimize the ejector efficiency. This study examines the effect of system parameters, such as an entrainment ratio (ω), pressure ratio (PR), circulation ratio (CR), and the effectiveness of heat exchangers on the thermal loads, the coefficients of performance (COP<inf>c</inf>, COP), and the efficiency ratio (η) at various operating temperatures of the components. The study also discussed the effect of the operating conditions of the proposed cycle components on the performance parameters and the CR value in details. Comparing the results between the proposed cycle and our previous work showed that the new arrangement of the refrigerant streamline side increases the energetic secondary flow and consequently improved ejector efficiency. Moreover, the results showed that the thermal loads decrement of the generator and the absorber with SHE effectiveness increment is about 38% for each; while the thermal loads increment of evaporator and absorber with RHE effectiveness increment is found 14.86%, and 8% respectively. The performance increase ratio at maximum heat exchanger effectiveness is found 60.7% for SHE and 14.86% for RHE. Overall, the proposed cycle is considered beneficial from the viewpoint of the first law of thermodynamics.

Original languageEnglish
Pages (from-to)222-234
Number of pages13
JournalChemical Engineering and Processing: Process Intensification
Volume95
DOIs
Publication statusPublished - 1 Sep 2015

Fingerprint

Absorption cooling
Refrigerants
Thermal load
Secondary flow
Heat exchangers
Evaporators
Thermodynamics
Fluids
Temperature

Keywords

  • Ejector-flash-tank-absorption system
  • Enhanced ejector efficiency
  • Improved refrigerant quality

ASJC Scopus subject areas

  • Chemical Engineering(all)
  • Chemistry(all)
  • Industrial and Manufacturing Engineering
  • Energy Engineering and Power Technology

Cite this

Evaluating ejector efficiency working under intermediate pressure of flash tank-absorption cooling cycle : Parametric study. / Abed, Azher M.; Alghoul, M. A.; Al-Shamani, Ali Najah; Sopian, Kamaruzzaman.

In: Chemical Engineering and Processing: Process Intensification, Vol. 95, 01.09.2015, p. 222-234.

Research output: Contribution to journalArticle

@article{b6175a03d889404c81c76400e3bf7238,
title = "Evaluating ejector efficiency working under intermediate pressure of flash tank-absorption cooling cycle: Parametric study",
abstract = "Combining the ejector-flash tank with the single stage absorption cycle using NH3/H2O as the working fluid has shown potential improvement in the COP. In our previous work, ejector efficiency faced some limitation due to the presence of booster at refrigerant streamline side. Removing the booster from the refrigerant streamline side and allowing the secondary flow of the ejector to work only under the intermediate pressure of the flash tank could optimize the ejector efficiency. This study examines the effect of system parameters, such as an entrainment ratio (ω), pressure ratio (PR), circulation ratio (CR), and the effectiveness of heat exchangers on the thermal loads, the coefficients of performance (COPc, COP), and the efficiency ratio (η) at various operating temperatures of the components. The study also discussed the effect of the operating conditions of the proposed cycle components on the performance parameters and the CR value in details. Comparing the results between the proposed cycle and our previous work showed that the new arrangement of the refrigerant streamline side increases the energetic secondary flow and consequently improved ejector efficiency. Moreover, the results showed that the thermal loads decrement of the generator and the absorber with SHE effectiveness increment is about 38{\%} for each; while the thermal loads increment of evaporator and absorber with RHE effectiveness increment is found 14.86{\%}, and 8{\%} respectively. The performance increase ratio at maximum heat exchanger effectiveness is found 60.7{\%} for SHE and 14.86{\%} for RHE. Overall, the proposed cycle is considered beneficial from the viewpoint of the first law of thermodynamics.",
keywords = "Ejector-flash-tank-absorption system, Enhanced ejector efficiency, Improved refrigerant quality",
author = "Abed, {Azher M.} and Alghoul, {M. A.} and Al-Shamani, {Ali Najah} and Kamaruzzaman Sopian",
year = "2015",
month = "9",
day = "1",
doi = "10.1016/j.cep.2015.06.009",
language = "English",
volume = "95",
pages = "222--234",
journal = "Chemical Engineering and Processing - Process Intensification",
issn = "0255-2701",
publisher = "Elsevier",

}

TY - JOUR

T1 - Evaluating ejector efficiency working under intermediate pressure of flash tank-absorption cooling cycle

T2 - Parametric study

AU - Abed, Azher M.

AU - Alghoul, M. A.

AU - Al-Shamani, Ali Najah

AU - Sopian, Kamaruzzaman

PY - 2015/9/1

Y1 - 2015/9/1

N2 - Combining the ejector-flash tank with the single stage absorption cycle using NH3/H2O as the working fluid has shown potential improvement in the COP. In our previous work, ejector efficiency faced some limitation due to the presence of booster at refrigerant streamline side. Removing the booster from the refrigerant streamline side and allowing the secondary flow of the ejector to work only under the intermediate pressure of the flash tank could optimize the ejector efficiency. This study examines the effect of system parameters, such as an entrainment ratio (ω), pressure ratio (PR), circulation ratio (CR), and the effectiveness of heat exchangers on the thermal loads, the coefficients of performance (COPc, COP), and the efficiency ratio (η) at various operating temperatures of the components. The study also discussed the effect of the operating conditions of the proposed cycle components on the performance parameters and the CR value in details. Comparing the results between the proposed cycle and our previous work showed that the new arrangement of the refrigerant streamline side increases the energetic secondary flow and consequently improved ejector efficiency. Moreover, the results showed that the thermal loads decrement of the generator and the absorber with SHE effectiveness increment is about 38% for each; while the thermal loads increment of evaporator and absorber with RHE effectiveness increment is found 14.86%, and 8% respectively. The performance increase ratio at maximum heat exchanger effectiveness is found 60.7% for SHE and 14.86% for RHE. Overall, the proposed cycle is considered beneficial from the viewpoint of the first law of thermodynamics.

AB - Combining the ejector-flash tank with the single stage absorption cycle using NH3/H2O as the working fluid has shown potential improvement in the COP. In our previous work, ejector efficiency faced some limitation due to the presence of booster at refrigerant streamline side. Removing the booster from the refrigerant streamline side and allowing the secondary flow of the ejector to work only under the intermediate pressure of the flash tank could optimize the ejector efficiency. This study examines the effect of system parameters, such as an entrainment ratio (ω), pressure ratio (PR), circulation ratio (CR), and the effectiveness of heat exchangers on the thermal loads, the coefficients of performance (COPc, COP), and the efficiency ratio (η) at various operating temperatures of the components. The study also discussed the effect of the operating conditions of the proposed cycle components on the performance parameters and the CR value in details. Comparing the results between the proposed cycle and our previous work showed that the new arrangement of the refrigerant streamline side increases the energetic secondary flow and consequently improved ejector efficiency. Moreover, the results showed that the thermal loads decrement of the generator and the absorber with SHE effectiveness increment is about 38% for each; while the thermal loads increment of evaporator and absorber with RHE effectiveness increment is found 14.86%, and 8% respectively. The performance increase ratio at maximum heat exchanger effectiveness is found 60.7% for SHE and 14.86% for RHE. Overall, the proposed cycle is considered beneficial from the viewpoint of the first law of thermodynamics.

KW - Ejector-flash-tank-absorption system

KW - Enhanced ejector efficiency

KW - Improved refrigerant quality

UR - http://www.scopus.com/inward/record.url?scp=84934756642&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84934756642&partnerID=8YFLogxK

U2 - 10.1016/j.cep.2015.06.009

DO - 10.1016/j.cep.2015.06.009

M3 - Article

AN - SCOPUS:84934756642

VL - 95

SP - 222

EP - 234

JO - Chemical Engineering and Processing - Process Intensification

JF - Chemical Engineering and Processing - Process Intensification

SN - 0255-2701

ER -