Sprawny układ odzyskiwania mocy w implantowych mikro-czujnikach

Translated title of the contribution: Efficient low-power recovery circuits for bio-implanted micro-sensors

Saad Mutashar, Hannan M A

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

This paper presents a modified sub-electronic circuit with low-power recovery circuits to be implemented in implanted micro-sensor used to stimulate the human and animals' nerves and muscles. The system based on ASK modulation techniques operated with 13. 56 MHz according to industrial, scientific, medical (ISM). The modulation index is 12. 6% to achieve minimum power consumption to avoid the tissue heating. The system consists of external part with modified class-E power amplifier efficiency 87. 2%, and internal part consists of a voltage doubling rectifier with self-threshold cancellation and efficient low-dropout voltage regulator based on series NMOST transistor using 0. 35 μm technology to offer very stable 1. 8 DC V. The produced voltage used to power the sub-electronic implanted device with steady voltage even in any changing with the implanted load resistance. The mathematical model is given. The design is simulated using OrCAD PSpice 16. 2 software tools and for real-time simulation, the electronic workbench MULISIM 11 has been used to simulate the class-E power amplifier.

Original languageUndefined/Unknown
Pages (from-to)15-18
Number of pages4
JournalPrzeglad Elektrotechniczny
Volume89
Issue number5
Publication statusPublished - 2013

Fingerprint

Power amplifiers
Recovery
Networks (circuits)
Sensors
Electric potential
Modulation
Voltage regulators
Muscle
Transistors
Animals
Electric power utilization
Tissue
Mathematical models
Heating
Amplitude shift keying

Keywords

  • ASK modulation
  • Bio-implanted devices
  • Class-E power amplifier
  • Rectifiers
  • Voltage regulators

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Sprawny układ odzyskiwania mocy w implantowych mikro-czujnikach. / Mutashar, Saad; M A, Hannan.

In: Przeglad Elektrotechniczny, Vol. 89, No. 5, 2013, p. 15-18.

Research output: Contribution to journalArticle

Mutashar, Saad ; M A, Hannan. / Sprawny układ odzyskiwania mocy w implantowych mikro-czujnikach. In: Przeglad Elektrotechniczny. 2013 ; Vol. 89, No. 5. pp. 15-18.
@article{199931683a7b4af0883fccbae20c5afa,
title = "Sprawny układ odzyskiwania mocy w implantowych mikro-czujnikach",
abstract = "This paper presents a modified sub-electronic circuit with low-power recovery circuits to be implemented in implanted micro-sensor used to stimulate the human and animals' nerves and muscles. The system based on ASK modulation techniques operated with 13. 56 MHz according to industrial, scientific, medical (ISM). The modulation index is 12. 6{\%} to achieve minimum power consumption to avoid the tissue heating. The system consists of external part with modified class-E power amplifier efficiency 87. 2{\%}, and internal part consists of a voltage doubling rectifier with self-threshold cancellation and efficient low-dropout voltage regulator based on series NMOST transistor using 0. 35 μm technology to offer very stable 1. 8 DC V. The produced voltage used to power the sub-electronic implanted device with steady voltage even in any changing with the implanted load resistance. The mathematical model is given. The design is simulated using OrCAD PSpice 16. 2 software tools and for real-time simulation, the electronic workbench MULISIM 11 has been used to simulate the class-E power amplifier.",
keywords = "ASK modulation, Bio-implanted devices, Class-E power amplifier, Rectifiers, Voltage regulators",
author = "Saad Mutashar and {M A}, Hannan",
year = "2013",
language = "Undefined/Unknown",
volume = "89",
pages = "15--18",
journal = "Przeglad Elektrotechniczny",
issn = "0033-2097",
publisher = "Wydawnictwo SIGMA - N O T Sp. z o.o.",
number = "5",

}

TY - JOUR

T1 - Sprawny układ odzyskiwania mocy w implantowych mikro-czujnikach

AU - Mutashar, Saad

AU - M A, Hannan

PY - 2013

Y1 - 2013

N2 - This paper presents a modified sub-electronic circuit with low-power recovery circuits to be implemented in implanted micro-sensor used to stimulate the human and animals' nerves and muscles. The system based on ASK modulation techniques operated with 13. 56 MHz according to industrial, scientific, medical (ISM). The modulation index is 12. 6% to achieve minimum power consumption to avoid the tissue heating. The system consists of external part with modified class-E power amplifier efficiency 87. 2%, and internal part consists of a voltage doubling rectifier with self-threshold cancellation and efficient low-dropout voltage regulator based on series NMOST transistor using 0. 35 μm technology to offer very stable 1. 8 DC V. The produced voltage used to power the sub-electronic implanted device with steady voltage even in any changing with the implanted load resistance. The mathematical model is given. The design is simulated using OrCAD PSpice 16. 2 software tools and for real-time simulation, the electronic workbench MULISIM 11 has been used to simulate the class-E power amplifier.

AB - This paper presents a modified sub-electronic circuit with low-power recovery circuits to be implemented in implanted micro-sensor used to stimulate the human and animals' nerves and muscles. The system based on ASK modulation techniques operated with 13. 56 MHz according to industrial, scientific, medical (ISM). The modulation index is 12. 6% to achieve minimum power consumption to avoid the tissue heating. The system consists of external part with modified class-E power amplifier efficiency 87. 2%, and internal part consists of a voltage doubling rectifier with self-threshold cancellation and efficient low-dropout voltage regulator based on series NMOST transistor using 0. 35 μm technology to offer very stable 1. 8 DC V. The produced voltage used to power the sub-electronic implanted device with steady voltage even in any changing with the implanted load resistance. The mathematical model is given. The design is simulated using OrCAD PSpice 16. 2 software tools and for real-time simulation, the electronic workbench MULISIM 11 has been used to simulate the class-E power amplifier.

KW - ASK modulation

KW - Bio-implanted devices

KW - Class-E power amplifier

KW - Rectifiers

KW - Voltage regulators

UR - http://www.scopus.com/inward/record.url?scp=84877100141&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877100141&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84877100141

VL - 89

SP - 15

EP - 18

JO - Przeglad Elektrotechniczny

JF - Przeglad Elektrotechniczny

SN - 0033-2097

IS - 5

ER -