Effective ventilation parameters and thermal comfort study of air-conditioned offices

Roonak Daghigh, Kamaruzzaman Sopian

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The study presents objective and subjective studies of thermal comfort levels and ventilation characteristics of two air-conditioned postgraduate study offices. The observations were performed at the offices of Department of Electrical and Electronic Engineering, in University Putra Malaysia. Thermal comfort variables were measured while the students answered a survey on their sensation of the indoor climate. Concurrently, tracer gas analysis, based on concentration decay method, is employed to determine air exchange rate, age of air and air exchange effectiveness. During the air conditioner is working, the study offices had not conditions within the comfort zone, of ASHRAE standard 55 causing occupants to report cold thermal sensations and the objective data analysis showed that the offices were uncomfortable. The thermal neutralities were significantly higher that proposed by ASHRAE Standard 55:1992. The monitored air exchange rates are indicated that the provisions of outside air for ventilation based on design occupancy are adequate for these two study offices. In addition, questionnaires were completed by the students in order to provide a subjective assessment of thermal comfort and indoor air quality. Finally, the outcomes of over 30 surveys for each office responses to the thermal comfort questions are presented and discussed.

Original languageEnglish
Pages (from-to)943-951
Number of pages9
JournalAmerican Journal of Applied Sciences
Volume6
Issue number5
DOIs
Publication statusPublished - 2009

Fingerprint

Thermal comfort
Ventilation
Air
Students
Electronics engineering
Gas fuel analysis
Electrical engineering
Air quality

Keywords

  • Air exchange effectiveness
  • Air-conditioning
  • Objective study
  • Subjective approach
  • Thermal comfort
  • Tracer gas decay method

ASJC Scopus subject areas

  • General

Cite this

Effective ventilation parameters and thermal comfort study of air-conditioned offices. / Daghigh, Roonak; Sopian, Kamaruzzaman.

In: American Journal of Applied Sciences, Vol. 6, No. 5, 2009, p. 943-951.

Research output: Contribution to journalArticle

@article{97afccb76b044d729597da3d2333d733,
title = "Effective ventilation parameters and thermal comfort study of air-conditioned offices",
abstract = "The study presents objective and subjective studies of thermal comfort levels and ventilation characteristics of two air-conditioned postgraduate study offices. The observations were performed at the offices of Department of Electrical and Electronic Engineering, in University Putra Malaysia. Thermal comfort variables were measured while the students answered a survey on their sensation of the indoor climate. Concurrently, tracer gas analysis, based on concentration decay method, is employed to determine air exchange rate, age of air and air exchange effectiveness. During the air conditioner is working, the study offices had not conditions within the comfort zone, of ASHRAE standard 55 causing occupants to report cold thermal sensations and the objective data analysis showed that the offices were uncomfortable. The thermal neutralities were significantly higher that proposed by ASHRAE Standard 55:1992. The monitored air exchange rates are indicated that the provisions of outside air for ventilation based on design occupancy are adequate for these two study offices. In addition, questionnaires were completed by the students in order to provide a subjective assessment of thermal comfort and indoor air quality. Finally, the outcomes of over 30 surveys for each office responses to the thermal comfort questions are presented and discussed.",
keywords = "Air exchange effectiveness, Air-conditioning, Objective study, Subjective approach, Thermal comfort, Tracer gas decay method",
author = "Roonak Daghigh and Kamaruzzaman Sopian",
year = "2009",
doi = "10.3844/ajas.2009.943.951",
language = "English",
volume = "6",
pages = "943--951",
journal = "American Journal of Applied Sciences",
issn = "1546-9239",
publisher = "Science Publications",
number = "5",

}

TY - JOUR

T1 - Effective ventilation parameters and thermal comfort study of air-conditioned offices

AU - Daghigh, Roonak

AU - Sopian, Kamaruzzaman

PY - 2009

Y1 - 2009

N2 - The study presents objective and subjective studies of thermal comfort levels and ventilation characteristics of two air-conditioned postgraduate study offices. The observations were performed at the offices of Department of Electrical and Electronic Engineering, in University Putra Malaysia. Thermal comfort variables were measured while the students answered a survey on their sensation of the indoor climate. Concurrently, tracer gas analysis, based on concentration decay method, is employed to determine air exchange rate, age of air and air exchange effectiveness. During the air conditioner is working, the study offices had not conditions within the comfort zone, of ASHRAE standard 55 causing occupants to report cold thermal sensations and the objective data analysis showed that the offices were uncomfortable. The thermal neutralities were significantly higher that proposed by ASHRAE Standard 55:1992. The monitored air exchange rates are indicated that the provisions of outside air for ventilation based on design occupancy are adequate for these two study offices. In addition, questionnaires were completed by the students in order to provide a subjective assessment of thermal comfort and indoor air quality. Finally, the outcomes of over 30 surveys for each office responses to the thermal comfort questions are presented and discussed.

AB - The study presents objective and subjective studies of thermal comfort levels and ventilation characteristics of two air-conditioned postgraduate study offices. The observations were performed at the offices of Department of Electrical and Electronic Engineering, in University Putra Malaysia. Thermal comfort variables were measured while the students answered a survey on their sensation of the indoor climate. Concurrently, tracer gas analysis, based on concentration decay method, is employed to determine air exchange rate, age of air and air exchange effectiveness. During the air conditioner is working, the study offices had not conditions within the comfort zone, of ASHRAE standard 55 causing occupants to report cold thermal sensations and the objective data analysis showed that the offices were uncomfortable. The thermal neutralities were significantly higher that proposed by ASHRAE Standard 55:1992. The monitored air exchange rates are indicated that the provisions of outside air for ventilation based on design occupancy are adequate for these two study offices. In addition, questionnaires were completed by the students in order to provide a subjective assessment of thermal comfort and indoor air quality. Finally, the outcomes of over 30 surveys for each office responses to the thermal comfort questions are presented and discussed.

KW - Air exchange effectiveness

KW - Air-conditioning

KW - Objective study

KW - Subjective approach

KW - Thermal comfort

KW - Tracer gas decay method

UR - http://www.scopus.com/inward/record.url?scp=77956931332&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956931332&partnerID=8YFLogxK

U2 - 10.3844/ajas.2009.943.951

DO - 10.3844/ajas.2009.943.951

M3 - Article

AN - SCOPUS:77956931332

VL - 6

SP - 943

EP - 951

JO - American Journal of Applied Sciences

JF - American Journal of Applied Sciences

SN - 1546-9239

IS - 5

ER -