Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing

Mohammad Mahdi Ariannejad, P. Susthitha Menon N V Visvanathan, Sahbudin Shaari, Abang Annuar Ehsan

Research output: Chapter in Book/Report/Conference proceedingConference contribution

4 Citations (Scopus)

Abstract

Ion-exchange technology on glass substrates for the fabrication of optical waveguides is a cost-effective and low loss method to produce biosensors. In this paper, the thermal ion-exchange process was simulated using a commercial software where various concentrations of AgNO3/NaNO3 salt-melt was deposited on Corning glass substrates at different temperatures and duration. Subsequently, a Mach-Zehnder Interferometer (MZI) was designed on glass substrates using OptiBPM software and the effect of the branching angle, a towards the power losses in the MZI was evaluated. Guided light suffers loss owing to the tapered andseparating structure of the MZI.

Original languageEnglish
Title of host publicationProceedings of ICP 2014 - 5th International Conference on Photonics 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages84-86
Number of pages3
ISBN (Print)9781479948833
DOIs
Publication statusPublished - 6 Jan 2015
Event5th International Conference on Photonics, ICP 2014 - Kuala Lumpur, Malaysia
Duration: 2 Sep 20144 Sep 2014

Other

Other5th International Conference on Photonics, ICP 2014
CountryMalaysia
CityKuala Lumpur
Period2/9/144/9/14

Fingerprint

Mach-Zehnder interferometers
Ion exchange
Glass
Substrates
Optical waveguides
Biosensors
Salts
Fabrication
Costs
Temperature

Keywords

  • biosensor
  • ion-exchange
  • Mach Zehnder Interferometer
  • optiBPM
  • optical waveg-uide

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Ariannejad, M. M., N V Visvanathan, P. S. M., Shaari, S., & Ehsan, A. A. (2015). Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing. In Proceedings of ICP 2014 - 5th International Conference on Photonics 2014 (pp. 84-86). [7002318] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICP.2014.7002318

Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing. / Ariannejad, Mohammad Mahdi; N V Visvanathan, P. Susthitha Menon; Shaari, Sahbudin; Ehsan, Abang Annuar.

Proceedings of ICP 2014 - 5th International Conference on Photonics 2014. Institute of Electrical and Electronics Engineers Inc., 2015. p. 84-86 7002318.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ariannejad, MM, N V Visvanathan, PSM, Shaari, S & Ehsan, AA 2015, Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing. in Proceedings of ICP 2014 - 5th International Conference on Photonics 2014., 7002318, Institute of Electrical and Electronics Engineers Inc., pp. 84-86, 5th International Conference on Photonics, ICP 2014, Kuala Lumpur, Malaysia, 2/9/14. https://doi.org/10.1109/ICP.2014.7002318
Ariannejad MM, N V Visvanathan PSM, Shaari S, Ehsan AA. Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing. In Proceedings of ICP 2014 - 5th International Conference on Photonics 2014. Institute of Electrical and Electronics Engineers Inc. 2015. p. 84-86. 7002318 https://doi.org/10.1109/ICP.2014.7002318
Ariannejad, Mohammad Mahdi ; N V Visvanathan, P. Susthitha Menon ; Shaari, Sahbudin ; Ehsan, Abang Annuar. / Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing. Proceedings of ICP 2014 - 5th International Conference on Photonics 2014. Institute of Electrical and Electronics Engineers Inc., 2015. pp. 84-86
@inproceedings{9c69f6625ee746b5a9dc491cfce2dc7e,
title = "Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing",
abstract = "Ion-exchange technology on glass substrates for the fabrication of optical waveguides is a cost-effective and low loss method to produce biosensors. In this paper, the thermal ion-exchange process was simulated using a commercial software where various concentrations of AgNO3/NaNO3 salt-melt was deposited on Corning glass substrates at different temperatures and duration. Subsequently, a Mach-Zehnder Interferometer (MZI) was designed on glass substrates using OptiBPM software and the effect of the branching angle, a towards the power losses in the MZI was evaluated. Guided light suffers loss owing to the tapered andseparating structure of the MZI.",
keywords = "biosensor, ion-exchange, Mach Zehnder Interferometer, optiBPM, optical waveg-uide",
author = "Ariannejad, {Mohammad Mahdi} and {N V Visvanathan}, {P. Susthitha Menon} and Sahbudin Shaari and Ehsan, {Abang Annuar}",
year = "2015",
month = "1",
day = "6",
doi = "10.1109/ICP.2014.7002318",
language = "English",
isbn = "9781479948833",
pages = "84--86",
booktitle = "Proceedings of ICP 2014 - 5th International Conference on Photonics 2014",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Design of optical Mach-Zehnder interferometer using ion exchange method for biosensing

AU - Ariannejad, Mohammad Mahdi

AU - N V Visvanathan, P. Susthitha Menon

AU - Shaari, Sahbudin

AU - Ehsan, Abang Annuar

PY - 2015/1/6

Y1 - 2015/1/6

N2 - Ion-exchange technology on glass substrates for the fabrication of optical waveguides is a cost-effective and low loss method to produce biosensors. In this paper, the thermal ion-exchange process was simulated using a commercial software where various concentrations of AgNO3/NaNO3 salt-melt was deposited on Corning glass substrates at different temperatures and duration. Subsequently, a Mach-Zehnder Interferometer (MZI) was designed on glass substrates using OptiBPM software and the effect of the branching angle, a towards the power losses in the MZI was evaluated. Guided light suffers loss owing to the tapered andseparating structure of the MZI.

AB - Ion-exchange technology on glass substrates for the fabrication of optical waveguides is a cost-effective and low loss method to produce biosensors. In this paper, the thermal ion-exchange process was simulated using a commercial software where various concentrations of AgNO3/NaNO3 salt-melt was deposited on Corning glass substrates at different temperatures and duration. Subsequently, a Mach-Zehnder Interferometer (MZI) was designed on glass substrates using OptiBPM software and the effect of the branching angle, a towards the power losses in the MZI was evaluated. Guided light suffers loss owing to the tapered andseparating structure of the MZI.

KW - biosensor

KW - ion-exchange

KW - Mach Zehnder Interferometer

KW - optiBPM

KW - optical waveg-uide

UR - http://www.scopus.com/inward/record.url?scp=84961341521&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84961341521&partnerID=8YFLogxK

U2 - 10.1109/ICP.2014.7002318

DO - 10.1109/ICP.2014.7002318

M3 - Conference contribution

SN - 9781479948833

SP - 84

EP - 86

BT - Proceedings of ICP 2014 - 5th International Conference on Photonics 2014

PB - Institute of Electrical and Electronics Engineers Inc.

ER -