Conventional tropical building designs are experiencing a new paradigm in their environmental response to improve lighting ambiance and occupants? visual comfort through the exploitation of daylighting. However, it is important for architects to understand that flaws in daylighting strategies could lead to disadvantages as they could hinder vision, cause discomfort, increase interior heat gain, and result in excessive energy demands. The objective of this study was to assess how occupants? perceived their visual conditions through daylight ratio and luminance level measurements. Measurements were conducted throughout a 2-month period starting from 12th May to 3rd July 2007. Three case studies were conducted at typical Malaysian hostels located in the Klang Valley. Those selected were: the Twelfth Residential College, Universiti Malaya (H1); the Eleventh Residential College, Universiti Putra Malaysia (H2); and Murni Student Apartments, Universiti Tenaga Nasional (H3). The daylighting source in all these case studies were from side-lit windows. Overall, the findings suggested that occupants were at ease with the level of daylighting available in their rooms even though rooms that were shaded by projecting balconies (i.e.,: H1) were dimmer than the rooms that were not shaded (i.e.,: H2 and H3).

Original languageEnglish
Pages (from-to)319-335
Number of pages17
JournalIndoor and Built Environment
Volume18
Issue number4
DOIs
Publication statusPublished - Aug 2009
Externally publishedYes

Fingerprint

Malaysia
Lighting
Hot Temperature
Students

Keywords

  • Daylight ratio
  • Illumination
  • Luminance
  • Objective measurement
  • Side-lit window
  • Subjective measurement
  • Visual comfort

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health

Cite this

Daylight ratio, luminance, and visual comfort assessments in typical malaysian hostels. / Dahlan, N. D.; Jones, P. J.; Alexander, D. K.; Salleh, Elias @ Ilias; Alias, J.

In: Indoor and Built Environment, Vol. 18, No. 4, 08.2009, p. 319-335.

Research output: Contribution to journalArticle

Dahlan, N. D. ; Jones, P. J. ; Alexander, D. K. ; Salleh, Elias @ Ilias ; Alias, J. / Daylight ratio, luminance, and visual comfort assessments in typical malaysian hostels. In: Indoor and Built Environment. 2009 ; Vol. 18, No. 4. pp. 319-335.
@article{e2f6cfb33228497fa4a83a5629405c14,
title = "Daylight ratio, luminance, and visual comfort assessments in typical malaysian hostels",
abstract = "Conventional tropical building designs are experiencing a new paradigm in their environmental response to improve lighting ambiance and occupants? visual comfort through the exploitation of daylighting. However, it is important for architects to understand that flaws in daylighting strategies could lead to disadvantages as they could hinder vision, cause discomfort, increase interior heat gain, and result in excessive energy demands. The objective of this study was to assess how occupants? perceived their visual conditions through daylight ratio and luminance level measurements. Measurements were conducted throughout a 2-month period starting from 12th May to 3rd July 2007. Three case studies were conducted at typical Malaysian hostels located in the Klang Valley. Those selected were: the Twelfth Residential College, Universiti Malaya (H1); the Eleventh Residential College, Universiti Putra Malaysia (H2); and Murni Student Apartments, Universiti Tenaga Nasional (H3). The daylighting source in all these case studies were from side-lit windows. Overall, the findings suggested that occupants were at ease with the level of daylighting available in their rooms even though rooms that were shaded by projecting balconies (i.e.,: H1) were dimmer than the rooms that were not shaded (i.e.,: H2 and H3).",
keywords = "Daylight ratio, Illumination, Luminance, Objective measurement, Side-lit window, Subjective measurement, Visual comfort",
author = "Dahlan, {N. D.} and Jones, {P. J.} and Alexander, {D. K.} and Salleh, {Elias @ Ilias} and J. Alias",
year = "2009",
month = "8",
doi = "10.1177/1420326X09337041",
language = "English",
volume = "18",
pages = "319--335",
journal = "Indoor and Built Environment",
issn = "1420-326X",
publisher = "SAGE Publications Ltd",
number = "4",

}

TY - JOUR

T1 - Daylight ratio, luminance, and visual comfort assessments in typical malaysian hostels

AU - Dahlan, N. D.

AU - Jones, P. J.

AU - Alexander, D. K.

AU - Salleh, Elias @ Ilias

AU - Alias, J.

PY - 2009/8

Y1 - 2009/8

N2 - Conventional tropical building designs are experiencing a new paradigm in their environmental response to improve lighting ambiance and occupants? visual comfort through the exploitation of daylighting. However, it is important for architects to understand that flaws in daylighting strategies could lead to disadvantages as they could hinder vision, cause discomfort, increase interior heat gain, and result in excessive energy demands. The objective of this study was to assess how occupants? perceived their visual conditions through daylight ratio and luminance level measurements. Measurements were conducted throughout a 2-month period starting from 12th May to 3rd July 2007. Three case studies were conducted at typical Malaysian hostels located in the Klang Valley. Those selected were: the Twelfth Residential College, Universiti Malaya (H1); the Eleventh Residential College, Universiti Putra Malaysia (H2); and Murni Student Apartments, Universiti Tenaga Nasional (H3). The daylighting source in all these case studies were from side-lit windows. Overall, the findings suggested that occupants were at ease with the level of daylighting available in their rooms even though rooms that were shaded by projecting balconies (i.e.,: H1) were dimmer than the rooms that were not shaded (i.e.,: H2 and H3).

AB - Conventional tropical building designs are experiencing a new paradigm in their environmental response to improve lighting ambiance and occupants? visual comfort through the exploitation of daylighting. However, it is important for architects to understand that flaws in daylighting strategies could lead to disadvantages as they could hinder vision, cause discomfort, increase interior heat gain, and result in excessive energy demands. The objective of this study was to assess how occupants? perceived their visual conditions through daylight ratio and luminance level measurements. Measurements were conducted throughout a 2-month period starting from 12th May to 3rd July 2007. Three case studies were conducted at typical Malaysian hostels located in the Klang Valley. Those selected were: the Twelfth Residential College, Universiti Malaya (H1); the Eleventh Residential College, Universiti Putra Malaysia (H2); and Murni Student Apartments, Universiti Tenaga Nasional (H3). The daylighting source in all these case studies were from side-lit windows. Overall, the findings suggested that occupants were at ease with the level of daylighting available in their rooms even though rooms that were shaded by projecting balconies (i.e.,: H1) were dimmer than the rooms that were not shaded (i.e.,: H2 and H3).

KW - Daylight ratio

KW - Illumination

KW - Luminance

KW - Objective measurement

KW - Side-lit window

KW - Subjective measurement

KW - Visual comfort

UR - http://www.scopus.com/inward/record.url?scp=70349673435&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70349673435&partnerID=8YFLogxK

U2 - 10.1177/1420326X09337041

DO - 10.1177/1420326X09337041

M3 - Article

VL - 18

SP - 319

EP - 335

JO - Indoor and Built Environment

JF - Indoor and Built Environment

SN - 1420-326X

IS - 4

ER -