Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna

Tahsina Islam, Hosna Ara Begum, Md Abdur Rahman, Tanveer Ahsan, Mohammed Shamsul Alam, Touhidul Alam, Md Samsuzzaman Sobuz, Mohammad Tariqul Islam

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Stroke is a leading cause of death and disability around the whole world. Currently computed axial tomography (CAT) scan, magnetic resonance imaging (MRI), positron emission tomography (PET) scan and ultrasound CAT scan, MRI, PET scan) and ultrasound are commonly used to detect brain stroke. However, these scan facilities are not available outside the hospital environment due to their large and bulky structure and beside this MRI is a very expensive diagnose system. In this research, a microwave imaging system utilizing unidirectional antenna is designed that uses the difference in contrast in the electrical properties between healthy and hemorrhaged brain tissues. Two unidirectional patch antennas are used in MWI simulation. One is used to transmit signal and another one is for receiving transmitted backscattered signal from various parts of the head. A homogeneous head phantom with the brain is placed between the transmitter and receiver antenna. An elliptical shaped blood clot (having density of 1060 Kg/m3, thermal conductivity of 0.51 W/K/m) is considered in the simulation system. The received backscattered signals are post-processed to generate a 2D image.

Original languageEnglish
Title of host publication2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages447-450
Number of pages4
ISBN (Electronic)9781538685242
DOIs
Publication statusPublished - 1 Oct 2018
Externally publishedYes
Event2nd International Conference on Innovations in Science, Engineering and Technology, ICISET 2018 - Chittagong, Bangladesh
Duration: 27 Oct 201828 Oct 2018

Publication series

Name2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018

Conference

Conference2nd International Conference on Innovations in Science, Engineering and Technology, ICISET 2018
CountryBangladesh
CityChittagong
Period27/10/1828/10/18

Fingerprint

strokes
Imaging systems
Screening
Magnetic resonance
screening
antennas
tomography
Microwaves
Antennas
brain
magnetic resonance
Imaging techniques
microwaves
Brain
Positron emission tomography
Tomography
positrons
Ultrasonics
disabilities
patch antennas

Keywords

  • antenna
  • backscattered signal
  • microwave imaging

ASJC Scopus subject areas

  • Computer Networks and Communications
  • Computer Science Applications
  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials
  • Instrumentation

Cite this

Islam, T., Begum, H. A., Abdur Rahman, M., Ahsan, T., Alam, M. S., Alam, T., ... Islam, M. T. (2018). Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna. In 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018 (pp. 447-450). [8745555] (2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICISET.2018.8745555

Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna. / Islam, Tahsina; Begum, Hosna Ara; Abdur Rahman, Md; Ahsan, Tanveer; Alam, Mohammed Shamsul; Alam, Touhidul; Sobuz, Md Samsuzzaman; Islam, Mohammad Tariqul.

2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018. Institute of Electrical and Electronics Engineers Inc., 2018. p. 447-450 8745555 (2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Islam, T, Begum, HA, Abdur Rahman, M, Ahsan, T, Alam, MS, Alam, T, Sobuz, MS & Islam, MT 2018, Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna. in 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018., 8745555, 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018, Institute of Electrical and Electronics Engineers Inc., pp. 447-450, 2nd International Conference on Innovations in Science, Engineering and Technology, ICISET 2018, Chittagong, Bangladesh, 27/10/18. https://doi.org/10.1109/ICISET.2018.8745555
Islam T, Begum HA, Abdur Rahman M, Ahsan T, Alam MS, Alam T et al. Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna. In 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018. Institute of Electrical and Electronics Engineers Inc. 2018. p. 447-450. 8745555. (2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018). https://doi.org/10.1109/ICISET.2018.8745555
Islam, Tahsina ; Begum, Hosna Ara ; Abdur Rahman, Md ; Ahsan, Tanveer ; Alam, Mohammed Shamsul ; Alam, Touhidul ; Sobuz, Md Samsuzzaman ; Islam, Mohammad Tariqul. / Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna. 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018. Institute of Electrical and Electronics Engineers Inc., 2018. pp. 447-450 (2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018).
@inproceedings{84e16a095abf46b4bd3c8da57f95a970,
title = "Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna",
abstract = "Stroke is a leading cause of death and disability around the whole world. Currently computed axial tomography (CAT) scan, magnetic resonance imaging (MRI), positron emission tomography (PET) scan and ultrasound CAT scan, MRI, PET scan) and ultrasound are commonly used to detect brain stroke. However, these scan facilities are not available outside the hospital environment due to their large and bulky structure and beside this MRI is a very expensive diagnose system. In this research, a microwave imaging system utilizing unidirectional antenna is designed that uses the difference in contrast in the electrical properties between healthy and hemorrhaged brain tissues. Two unidirectional patch antennas are used in MWI simulation. One is used to transmit signal and another one is for receiving transmitted backscattered signal from various parts of the head. A homogeneous head phantom with the brain is placed between the transmitter and receiver antenna. An elliptical shaped blood clot (having density of 1060 Kg/m3, thermal conductivity of 0.51 W/K/m) is considered in the simulation system. The received backscattered signals are post-processed to generate a 2D image.",
keywords = "antenna, backscattered signal, microwave imaging",
author = "Tahsina Islam and Begum, {Hosna Ara} and {Abdur Rahman}, Md and Tanveer Ahsan and Alam, {Mohammed Shamsul} and Touhidul Alam and Sobuz, {Md Samsuzzaman} and Islam, {Mohammad Tariqul}",
year = "2018",
month = "10",
day = "1",
doi = "10.1109/ICISET.2018.8745555",
language = "English",
series = "2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "447--450",
booktitle = "2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018",

}

TY - GEN

T1 - Computational analysis of Microwave Imaging (MWI) System for Post Stroke Screening Using Unidirectional Antenna

AU - Islam, Tahsina

AU - Begum, Hosna Ara

AU - Abdur Rahman, Md

AU - Ahsan, Tanveer

AU - Alam, Mohammed Shamsul

AU - Alam, Touhidul

AU - Sobuz, Md Samsuzzaman

AU - Islam, Mohammad Tariqul

PY - 2018/10/1

Y1 - 2018/10/1

N2 - Stroke is a leading cause of death and disability around the whole world. Currently computed axial tomography (CAT) scan, magnetic resonance imaging (MRI), positron emission tomography (PET) scan and ultrasound CAT scan, MRI, PET scan) and ultrasound are commonly used to detect brain stroke. However, these scan facilities are not available outside the hospital environment due to their large and bulky structure and beside this MRI is a very expensive diagnose system. In this research, a microwave imaging system utilizing unidirectional antenna is designed that uses the difference in contrast in the electrical properties between healthy and hemorrhaged brain tissues. Two unidirectional patch antennas are used in MWI simulation. One is used to transmit signal and another one is for receiving transmitted backscattered signal from various parts of the head. A homogeneous head phantom with the brain is placed between the transmitter and receiver antenna. An elliptical shaped blood clot (having density of 1060 Kg/m3, thermal conductivity of 0.51 W/K/m) is considered in the simulation system. The received backscattered signals are post-processed to generate a 2D image.

AB - Stroke is a leading cause of death and disability around the whole world. Currently computed axial tomography (CAT) scan, magnetic resonance imaging (MRI), positron emission tomography (PET) scan and ultrasound CAT scan, MRI, PET scan) and ultrasound are commonly used to detect brain stroke. However, these scan facilities are not available outside the hospital environment due to their large and bulky structure and beside this MRI is a very expensive diagnose system. In this research, a microwave imaging system utilizing unidirectional antenna is designed that uses the difference in contrast in the electrical properties between healthy and hemorrhaged brain tissues. Two unidirectional patch antennas are used in MWI simulation. One is used to transmit signal and another one is for receiving transmitted backscattered signal from various parts of the head. A homogeneous head phantom with the brain is placed between the transmitter and receiver antenna. An elliptical shaped blood clot (having density of 1060 Kg/m3, thermal conductivity of 0.51 W/K/m) is considered in the simulation system. The received backscattered signals are post-processed to generate a 2D image.

KW - antenna

KW - backscattered signal

KW - microwave imaging

UR - http://www.scopus.com/inward/record.url?scp=85069160870&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85069160870&partnerID=8YFLogxK

U2 - 10.1109/ICISET.2018.8745555

DO - 10.1109/ICISET.2018.8745555

M3 - Conference contribution

T3 - 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018

SP - 447

EP - 450

BT - 2018 International Conference on Innovations in Science, Engineering and Technology, ICISET 2018

PB - Institute of Electrical and Electronics Engineers Inc.

ER -