Colour vision status of staff working with radiation in public hospital

Research output: Contribution to journalArticle

Abstract

Growing application of radiation sources and lack of awareness among workers in practicing protective measures imply an increased risk of radiation exposure to eye. This study determined the status of colour vision and its association with working duration amongst staff working with radiation in a university hospital. A total of 55 employees (28 exposed (RS) and 27 not directly exposed to radiation (NRS)) were recruited and 30 employees were used as controls. Visual acuity (VA) was measured using Snellen chart. Colour vision assessments were conducted using Ishihara plates, D15 panel and FM 100 hues and the results were analysed using one way ANOVA. The subjects’ age ranged between 29 and 44 years old. Mean VA for all subjects was 6/6. More than 50% of the subjects has colour defects, 3.45% of RS failed D15, 37.93% failed FM 100 hue, 7.4% of NRS failed D15 and 55.56% failed FM 100 hue. Significant difference was found in the total error scores between RS (77.10 ± 6.05) and NRS (84.89 ± 7.76) with the controls (41.47 ± 3.10) [ANOVA F(2,83)=16.084, p=0.00]. There was no association between working duration and severity of colour defect [r(104)= -0.123, p>0.05]. This study concludes that majority of the studied subjects has color deficiency but not significantly correlated with their working duration. Protective measures need to be taken to improve the situation.

Original languageEnglish
Pages (from-to)2319-2323
Number of pages5
JournalSains Malaysiana
Volume47
Issue number10
DOIs
Publication statusPublished - 1 Oct 2018

Fingerprint

Color Vision
Public Hospitals
Color
Radiation
Visual Acuity
Analysis of Variance
FM 100

Keywords

  • Colour defect
  • Colour perception
  • Occupational radiation exposure

ASJC Scopus subject areas

  • General

Cite this

Colour vision status of staff working with radiation in public hospital. / Mohd. Ali, Bariah; Yee, Wong Mei; Ishak, Bashirah.

In: Sains Malaysiana, Vol. 47, No. 10, 01.10.2018, p. 2319-2323.

Research output: Contribution to journalArticle

@article{3527fad398ce49ecb4d7a52683145848,
title = "Colour vision status of staff working with radiation in public hospital",
abstract = "Growing application of radiation sources and lack of awareness among workers in practicing protective measures imply an increased risk of radiation exposure to eye. This study determined the status of colour vision and its association with working duration amongst staff working with radiation in a university hospital. A total of 55 employees (28 exposed (RS) and 27 not directly exposed to radiation (NRS)) were recruited and 30 employees were used as controls. Visual acuity (VA) was measured using Snellen chart. Colour vision assessments were conducted using Ishihara plates, D15 panel and FM 100 hues and the results were analysed using one way ANOVA. The subjects’ age ranged between 29 and 44 years old. Mean VA for all subjects was 6/6. More than 50{\%} of the subjects has colour defects, 3.45{\%} of RS failed D15, 37.93{\%} failed FM 100 hue, 7.4{\%} of NRS failed D15 and 55.56{\%} failed FM 100 hue. Significant difference was found in the total error scores between RS (77.10 ± 6.05) and NRS (84.89 ± 7.76) with the controls (41.47 ± 3.10) [ANOVA F(2,83)=16.084, p=0.00]. There was no association between working duration and severity of colour defect [r(104)= -0.123, p>0.05]. This study concludes that majority of the studied subjects has color deficiency but not significantly correlated with their working duration. Protective measures need to be taken to improve the situation.",
keywords = "Colour defect, Colour perception, Occupational radiation exposure",
author = "{Mohd. Ali}, Bariah and Yee, {Wong Mei} and Bashirah Ishak",
year = "2018",
month = "10",
day = "1",
doi = "10.17576/jsm-2018-4710-08",
language = "English",
volume = "47",
pages = "2319--2323",
journal = "Sains Malaysiana",
issn = "0126-6039",
publisher = "Penerbit Universiti Kebangsaan Malaysia",
number = "10",

}

TY - JOUR

T1 - Colour vision status of staff working with radiation in public hospital

AU - Mohd. Ali, Bariah

AU - Yee, Wong Mei

AU - Ishak, Bashirah

PY - 2018/10/1

Y1 - 2018/10/1

N2 - Growing application of radiation sources and lack of awareness among workers in practicing protective measures imply an increased risk of radiation exposure to eye. This study determined the status of colour vision and its association with working duration amongst staff working with radiation in a university hospital. A total of 55 employees (28 exposed (RS) and 27 not directly exposed to radiation (NRS)) were recruited and 30 employees were used as controls. Visual acuity (VA) was measured using Snellen chart. Colour vision assessments were conducted using Ishihara plates, D15 panel and FM 100 hues and the results were analysed using one way ANOVA. The subjects’ age ranged between 29 and 44 years old. Mean VA for all subjects was 6/6. More than 50% of the subjects has colour defects, 3.45% of RS failed D15, 37.93% failed FM 100 hue, 7.4% of NRS failed D15 and 55.56% failed FM 100 hue. Significant difference was found in the total error scores between RS (77.10 ± 6.05) and NRS (84.89 ± 7.76) with the controls (41.47 ± 3.10) [ANOVA F(2,83)=16.084, p=0.00]. There was no association between working duration and severity of colour defect [r(104)= -0.123, p>0.05]. This study concludes that majority of the studied subjects has color deficiency but not significantly correlated with their working duration. Protective measures need to be taken to improve the situation.

AB - Growing application of radiation sources and lack of awareness among workers in practicing protective measures imply an increased risk of radiation exposure to eye. This study determined the status of colour vision and its association with working duration amongst staff working with radiation in a university hospital. A total of 55 employees (28 exposed (RS) and 27 not directly exposed to radiation (NRS)) were recruited and 30 employees were used as controls. Visual acuity (VA) was measured using Snellen chart. Colour vision assessments were conducted using Ishihara plates, D15 panel and FM 100 hues and the results were analysed using one way ANOVA. The subjects’ age ranged between 29 and 44 years old. Mean VA for all subjects was 6/6. More than 50% of the subjects has colour defects, 3.45% of RS failed D15, 37.93% failed FM 100 hue, 7.4% of NRS failed D15 and 55.56% failed FM 100 hue. Significant difference was found in the total error scores between RS (77.10 ± 6.05) and NRS (84.89 ± 7.76) with the controls (41.47 ± 3.10) [ANOVA F(2,83)=16.084, p=0.00]. There was no association between working duration and severity of colour defect [r(104)= -0.123, p>0.05]. This study concludes that majority of the studied subjects has color deficiency but not significantly correlated with their working duration. Protective measures need to be taken to improve the situation.

KW - Colour defect

KW - Colour perception

KW - Occupational radiation exposure

UR - http://www.scopus.com/inward/record.url?scp=85057445229&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057445229&partnerID=8YFLogxK

U2 - 10.17576/jsm-2018-4710-08

DO - 10.17576/jsm-2018-4710-08

M3 - Article

VL - 47

SP - 2319

EP - 2323

JO - Sains Malaysiana

JF - Sains Malaysiana

SN - 0126-6039

IS - 10

ER -