Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A charge collection efficiency (CCE) measurement system has been developed for CCE measurement of semiconductor nuclear detector using a nuclear counting system interface to a PC for data acquisition. A Field Programmable Gate Array (FPGA) based multipurpose card used for system development due to analog digital converter (ADC) and multichannel analyzer (MCA) functions needed for data acquisition available on board. This multipurpose card also portable and can easily interfaced to a computer. A data acquisition of CCE measurement system namely CCE Measurement V.1.0 also developed using LabVIEW 8.6. The CCE measurement system developed is a user friendly measurement system as it contains detector information, experimental, analysis and documentation. So, measurement results can automatically prepared during system execution. A CCE measurement of CdZnTe semiconductor detector AMPTEK XR-100T-CZT exposed to Cs-137 with 10.45 μCi activity with an increasing operating voltage proved that this developed measurement system is functional and ready to use.

Original languageEnglish
Title of host publication2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings
Pages592-595
Number of pages4
DOIs
Publication statusPublished - 2012
Event2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Kuala Lumpur
Duration: 19 Sep 201221 Sep 2012

Other

Other2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012
CityKuala Lumpur
Period19/9/1221/9/12

Fingerprint

Field programmable gate arrays (FPGA)
Data acquisition
Detectors
Semiconductor detectors
Digital to analog conversion
Semiconductor materials
Electric potential

Keywords

  • charge collection efficiency (CCE)
  • field programmable gate array (FPGA)
  • nuclear counting system
  • semiconductor radiation detector

ASJC Scopus subject areas

  • Hardware and Architecture
  • Electrical and Electronic Engineering

Cite this

Saad, N., Mansor, I., Abdul Hamid, M. A., Jalar @ Jalil, A., & Shamsudin, R. (2012). Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card. In 2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings (pp. 592-595). [6417215] https://doi.org/10.1109/SMElec.2012.6417215

Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card. / Saad, Norizam; Mansor, Ishak; Abdul Hamid, Muhammad Azmi; Jalar @ Jalil, Azman; Shamsudin, Roslinda.

2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings. 2012. p. 592-595 6417215.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Saad, N, Mansor, I, Abdul Hamid, MA, Jalar @ Jalil, A & Shamsudin, R 2012, Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card. in 2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings., 6417215, pp. 592-595, 2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012, Kuala Lumpur, 19/9/12. https://doi.org/10.1109/SMElec.2012.6417215
Saad N, Mansor I, Abdul Hamid MA, Jalar @ Jalil A, Shamsudin R. Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card. In 2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings. 2012. p. 592-595. 6417215 https://doi.org/10.1109/SMElec.2012.6417215
Saad, Norizam ; Mansor, Ishak ; Abdul Hamid, Muhammad Azmi ; Jalar @ Jalil, Azman ; Shamsudin, Roslinda. / Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card. 2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings. 2012. pp. 592-595
@inproceedings{34edb4e91300404e87cfb13256d614b6,
title = "Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card",
abstract = "A charge collection efficiency (CCE) measurement system has been developed for CCE measurement of semiconductor nuclear detector using a nuclear counting system interface to a PC for data acquisition. A Field Programmable Gate Array (FPGA) based multipurpose card used for system development due to analog digital converter (ADC) and multichannel analyzer (MCA) functions needed for data acquisition available on board. This multipurpose card also portable and can easily interfaced to a computer. A data acquisition of CCE measurement system namely CCE Measurement V.1.0 also developed using LabVIEW 8.6. The CCE measurement system developed is a user friendly measurement system as it contains detector information, experimental, analysis and documentation. So, measurement results can automatically prepared during system execution. A CCE measurement of CdZnTe semiconductor detector AMPTEK XR-100T-CZT exposed to Cs-137 with 10.45 μCi activity with an increasing operating voltage proved that this developed measurement system is functional and ready to use.",
keywords = "charge collection efficiency (CCE), field programmable gate array (FPGA), nuclear counting system, semiconductor radiation detector",
author = "Norizam Saad and Ishak Mansor and {Abdul Hamid}, {Muhammad Azmi} and {Jalar @ Jalil}, Azman and Roslinda Shamsudin",
year = "2012",
doi = "10.1109/SMElec.2012.6417215",
language = "English",
isbn = "9781467323963",
pages = "592--595",
booktitle = "2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings",

}

TY - GEN

T1 - Charge collection efficiency measurement system based on Field Programmable Gate Array multipurpose card

AU - Saad, Norizam

AU - Mansor, Ishak

AU - Abdul Hamid, Muhammad Azmi

AU - Jalar @ Jalil, Azman

AU - Shamsudin, Roslinda

PY - 2012

Y1 - 2012

N2 - A charge collection efficiency (CCE) measurement system has been developed for CCE measurement of semiconductor nuclear detector using a nuclear counting system interface to a PC for data acquisition. A Field Programmable Gate Array (FPGA) based multipurpose card used for system development due to analog digital converter (ADC) and multichannel analyzer (MCA) functions needed for data acquisition available on board. This multipurpose card also portable and can easily interfaced to a computer. A data acquisition of CCE measurement system namely CCE Measurement V.1.0 also developed using LabVIEW 8.6. The CCE measurement system developed is a user friendly measurement system as it contains detector information, experimental, analysis and documentation. So, measurement results can automatically prepared during system execution. A CCE measurement of CdZnTe semiconductor detector AMPTEK XR-100T-CZT exposed to Cs-137 with 10.45 μCi activity with an increasing operating voltage proved that this developed measurement system is functional and ready to use.

AB - A charge collection efficiency (CCE) measurement system has been developed for CCE measurement of semiconductor nuclear detector using a nuclear counting system interface to a PC for data acquisition. A Field Programmable Gate Array (FPGA) based multipurpose card used for system development due to analog digital converter (ADC) and multichannel analyzer (MCA) functions needed for data acquisition available on board. This multipurpose card also portable and can easily interfaced to a computer. A data acquisition of CCE measurement system namely CCE Measurement V.1.0 also developed using LabVIEW 8.6. The CCE measurement system developed is a user friendly measurement system as it contains detector information, experimental, analysis and documentation. So, measurement results can automatically prepared during system execution. A CCE measurement of CdZnTe semiconductor detector AMPTEK XR-100T-CZT exposed to Cs-137 with 10.45 μCi activity with an increasing operating voltage proved that this developed measurement system is functional and ready to use.

KW - charge collection efficiency (CCE)

KW - field programmable gate array (FPGA)

KW - nuclear counting system

KW - semiconductor radiation detector

UR - http://www.scopus.com/inward/record.url?scp=84874185771&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874185771&partnerID=8YFLogxK

U2 - 10.1109/SMElec.2012.6417215

DO - 10.1109/SMElec.2012.6417215

M3 - Conference contribution

AN - SCOPUS:84874185771

SN - 9781467323963

SP - 592

EP - 595

BT - 2012 10th IEEE International Conference on Semiconductor Electronics, ICSE 2012 - Proceedings

ER -