This paper describes performance solar water heating for flat plate collector. The system of thermal performance designed for dimensions 125×110cm and width 25cm, in such a way that fluid can flow from inlet to outlet through pipe with longer is 15.9m, designed as lope square pattern, used the water as fluid flow working with two different flow rate (5.3 and 6.51L/min). The experiments were carried out under the University of Technology, conditions of Baghdad, Iraq. The result shows that the water at flow rate 5.3L/min heated more than the flow rate 6.51L/min, which causes the higher efficiency and effectiveness of the collector, so the maximum temperature was (51.4°C and 49°C) at flow rate (5.3L/min and 6.51L/min) respectively. The main conclusion is that used this system to heated the water and then used in-house, building and other purposes.

Original languageEnglish
Pages (from-to)666-671
Number of pages6
JournalCase Studies in Thermal Engineering
Volume12
DOIs
Publication statusPublished - 1 Sep 2018

Fingerprint

Flow rate
Heating
Water
Flow of fluids
Pipe
Experiments
Temperature

Keywords

  • Flat plate collector
  • Solar water heated
  • Thermal performance

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Fluid Flow and Transfer Processes

Cite this

Hashim, W. M., Shomran, A. T., Jurmut, H. A., Gaaz, T. S., Kadhum, A. A. H., & Al-Amiery, A. A. (2018). Case study on solar water heating for flat plate collector. Case Studies in Thermal Engineering, 12, 666-671. https://doi.org/10.1016/j.csite.2018.09.002

Case study on solar water heating for flat plate collector. / Hashim, Walaa Mousa; Shomran, Ali Talib; Jurmut, Hasan Ali; Gaaz, Tayser Sume; Kadhum, Abdul Amir H.; Al-Amiery, Ahmed A.

In: Case Studies in Thermal Engineering, Vol. 12, 01.09.2018, p. 666-671.

Research output: Contribution to journalArticle

Hashim, Walaa Mousa ; Shomran, Ali Talib ; Jurmut, Hasan Ali ; Gaaz, Tayser Sume ; Kadhum, Abdul Amir H. ; Al-Amiery, Ahmed A. / Case study on solar water heating for flat plate collector. In: Case Studies in Thermal Engineering. 2018 ; Vol. 12. pp. 666-671.
@article{eb947cc32c934327aca4f2018345b54a,
title = "Case study on solar water heating for flat plate collector",
abstract = "This paper describes performance solar water heating for flat plate collector. The system of thermal performance designed for dimensions 125×110cm and width 25cm, in such a way that fluid can flow from inlet to outlet through pipe with longer is 15.9m, designed as lope square pattern, used the water as fluid flow working with two different flow rate (5.3 and 6.51L/min). The experiments were carried out under the University of Technology, conditions of Baghdad, Iraq. The result shows that the water at flow rate 5.3L/min heated more than the flow rate 6.51L/min, which causes the higher efficiency and effectiveness of the collector, so the maximum temperature was (51.4°C and 49°C) at flow rate (5.3L/min and 6.51L/min) respectively. The main conclusion is that used this system to heated the water and then used in-house, building and other purposes.",
keywords = "Flat plate collector, Solar water heated, Thermal performance",
author = "Hashim, {Walaa Mousa} and Shomran, {Ali Talib} and Jurmut, {Hasan Ali} and Gaaz, {Tayser Sume} and Kadhum, {Abdul Amir H.} and Al-Amiery, {Ahmed A.}",
year = "2018",
month = "9",
day = "1",
doi = "10.1016/j.csite.2018.09.002",
language = "English",
volume = "12",
pages = "666--671",
journal = "Case Studies in Thermal Engineering",
issn = "2214-157X",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Case study on solar water heating for flat plate collector

AU - Hashim, Walaa Mousa

AU - Shomran, Ali Talib

AU - Jurmut, Hasan Ali

AU - Gaaz, Tayser Sume

AU - Kadhum, Abdul Amir H.

AU - Al-Amiery, Ahmed A.

PY - 2018/9/1

Y1 - 2018/9/1

N2 - This paper describes performance solar water heating for flat plate collector. The system of thermal performance designed for dimensions 125×110cm and width 25cm, in such a way that fluid can flow from inlet to outlet through pipe with longer is 15.9m, designed as lope square pattern, used the water as fluid flow working with two different flow rate (5.3 and 6.51L/min). The experiments were carried out under the University of Technology, conditions of Baghdad, Iraq. The result shows that the water at flow rate 5.3L/min heated more than the flow rate 6.51L/min, which causes the higher efficiency and effectiveness of the collector, so the maximum temperature was (51.4°C and 49°C) at flow rate (5.3L/min and 6.51L/min) respectively. The main conclusion is that used this system to heated the water and then used in-house, building and other purposes.

AB - This paper describes performance solar water heating for flat plate collector. The system of thermal performance designed for dimensions 125×110cm and width 25cm, in such a way that fluid can flow from inlet to outlet through pipe with longer is 15.9m, designed as lope square pattern, used the water as fluid flow working with two different flow rate (5.3 and 6.51L/min). The experiments were carried out under the University of Technology, conditions of Baghdad, Iraq. The result shows that the water at flow rate 5.3L/min heated more than the flow rate 6.51L/min, which causes the higher efficiency and effectiveness of the collector, so the maximum temperature was (51.4°C and 49°C) at flow rate (5.3L/min and 6.51L/min) respectively. The main conclusion is that used this system to heated the water and then used in-house, building and other purposes.

KW - Flat plate collector

KW - Solar water heated

KW - Thermal performance

UR - http://www.scopus.com/inward/record.url?scp=85053154023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053154023&partnerID=8YFLogxK

U2 - 10.1016/j.csite.2018.09.002

DO - 10.1016/j.csite.2018.09.002

M3 - Article

VL - 12

SP - 666

EP - 671

JO - Case Studies in Thermal Engineering

JF - Case Studies in Thermal Engineering

SN - 2214-157X

ER -