The school buildings condition is an important factor in influencing school learning environment. This study aims to contribute in establishing the actual condition of primary school buildings in Sarawak, Malaysia. It focuses on the relation of school's age and building condition. The primary data is collected via building condition survey from 24 primary schools using Condition Survey Protocol (CSP) 1 Matrix and analyze via Statistical Package for Social Sciences. The school age is taken up as main parameter towards the analysis of number of defects, total marks and overall building condition. The analysis carried out found that 4,725 defects have been identified and the overall rating for all school is 9.71 which is at the fair condition. The findings proved that building age is closely related to buildings condition and it supported the prevalence theory that 'the aging building has more defect than the new one'. This indicates that the maintenance mentality is still in traditional mode and remains unchanged. The finding could assist relevant parties to take appropriate action in improving school facilities condition.

Original languageEnglish
Pages (from-to)565-572
Number of pages8
JournalResearch Journal of Applied Sciences
Volume9
Issue number9
DOIs
Publication statusPublished - 2014

Fingerprint

School buildings
Defects
matrices
Social sciences
Aging of materials
defects
Malaysia
ratings
learning
maintenance

Keywords

  • Assessment
  • Building condition
  • CSP1 matrix
  • Malaysia
  • School

ASJC Scopus subject areas

  • General
  • Engineering(all)

Cite this

Building condition assessment using condition survey protocol matrix : A case of school building. / Samah, A. H.; Mohd Tawil, Norngainy; Mahli, M.; Che-Am, A. I.; Abd-Razak, M. Z.

In: Research Journal of Applied Sciences, Vol. 9, No. 9, 2014, p. 565-572.

Research output: Contribution to journalArticle

Samah, A. H. ; Mohd Tawil, Norngainy ; Mahli, M. ; Che-Am, A. I. ; Abd-Razak, M. Z. / Building condition assessment using condition survey protocol matrix : A case of school building. In: Research Journal of Applied Sciences. 2014 ; Vol. 9, No. 9. pp. 565-572.
@article{0f9fbc5d77e840328bf56564076bfede,
title = "Building condition assessment using condition survey protocol matrix: A case of school building",
abstract = "The school buildings condition is an important factor in influencing school learning environment. This study aims to contribute in establishing the actual condition of primary school buildings in Sarawak, Malaysia. It focuses on the relation of school's age and building condition. The primary data is collected via building condition survey from 24 primary schools using Condition Survey Protocol (CSP) 1 Matrix and analyze via Statistical Package for Social Sciences. The school age is taken up as main parameter towards the analysis of number of defects, total marks and overall building condition. The analysis carried out found that 4,725 defects have been identified and the overall rating for all school is 9.71 which is at the fair condition. The findings proved that building age is closely related to buildings condition and it supported the prevalence theory that 'the aging building has more defect than the new one'. This indicates that the maintenance mentality is still in traditional mode and remains unchanged. The finding could assist relevant parties to take appropriate action in improving school facilities condition.",
keywords = "Assessment, Building condition, CSP1 matrix, Malaysia, School",
author = "Samah, {A. H.} and {Mohd Tawil}, Norngainy and M. Mahli and Che-Am, {A. I.} and Abd-Razak, {M. Z.}",
year = "2014",
doi = "10.3923/rjasci.2014.565.572",
language = "English",
volume = "9",
pages = "565--572",
journal = "Research Journal of Applied Sciences",
issn = "1815-932X",
publisher = "Medwell Publishing",
number = "9",

}

TY - JOUR

T1 - Building condition assessment using condition survey protocol matrix

T2 - A case of school building

AU - Samah, A. H.

AU - Mohd Tawil, Norngainy

AU - Mahli, M.

AU - Che-Am, A. I.

AU - Abd-Razak, M. Z.

PY - 2014

Y1 - 2014

N2 - The school buildings condition is an important factor in influencing school learning environment. This study aims to contribute in establishing the actual condition of primary school buildings in Sarawak, Malaysia. It focuses on the relation of school's age and building condition. The primary data is collected via building condition survey from 24 primary schools using Condition Survey Protocol (CSP) 1 Matrix and analyze via Statistical Package for Social Sciences. The school age is taken up as main parameter towards the analysis of number of defects, total marks and overall building condition. The analysis carried out found that 4,725 defects have been identified and the overall rating for all school is 9.71 which is at the fair condition. The findings proved that building age is closely related to buildings condition and it supported the prevalence theory that 'the aging building has more defect than the new one'. This indicates that the maintenance mentality is still in traditional mode and remains unchanged. The finding could assist relevant parties to take appropriate action in improving school facilities condition.

AB - The school buildings condition is an important factor in influencing school learning environment. This study aims to contribute in establishing the actual condition of primary school buildings in Sarawak, Malaysia. It focuses on the relation of school's age and building condition. The primary data is collected via building condition survey from 24 primary schools using Condition Survey Protocol (CSP) 1 Matrix and analyze via Statistical Package for Social Sciences. The school age is taken up as main parameter towards the analysis of number of defects, total marks and overall building condition. The analysis carried out found that 4,725 defects have been identified and the overall rating for all school is 9.71 which is at the fair condition. The findings proved that building age is closely related to buildings condition and it supported the prevalence theory that 'the aging building has more defect than the new one'. This indicates that the maintenance mentality is still in traditional mode and remains unchanged. The finding could assist relevant parties to take appropriate action in improving school facilities condition.

KW - Assessment

KW - Building condition

KW - CSP1 matrix

KW - Malaysia

KW - School

UR - http://www.scopus.com/inward/record.url?scp=84908221063&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84908221063&partnerID=8YFLogxK

U2 - 10.3923/rjasci.2014.565.572

DO - 10.3923/rjasci.2014.565.572

M3 - Article

AN - SCOPUS:84908221063

VL - 9

SP - 565

EP - 572

JO - Research Journal of Applied Sciences

JF - Research Journal of Applied Sciences

SN - 1815-932X

IS - 9

ER -