Application of SANTAD in network monitoring and fault detection of FTTH-PON

Ng Boon Chuan, Mohd Syuhaimi Ab Rahman, Aswir Premadi, Kasmiran Jumari

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

This paper presented a new approach to monitor the network performance and detect any occurrence of fault in fiberto- the-home passive optical network (FTTH-PON) using an efficient monitoring system named Smart Access Network-Testing, Analyzing and Database (SANTAD). An optical time domain reflectometer (OTDR) with 1625 nm laser source is located at central office (CO) and connected to a remote personnel computer (PC) via Ethernet TCP/IP connection. A tapper circuit is designed to allow the OTDR testing signal to bypass the optical splitter in a conventional FTTH-PON when emitted in downstream direction. The key idea is to accumulate all OTDR measurement to be displayed on a PC computer screen for centralized monitoring and advanced data analyzing. The main advantages of this work is to improve the survivability and efficiency of FTTH-PON, while reduce the hands on workload as well as maintenance cost and time. The proposed system was implemented in a FTTH-PON network testbed and the experimental results showed that the proposed system achieves high accuracy in addressing the exact failure location.

Original languageEnglish
Title of host publicationProceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009
Pages453-458
Number of pages6
Volume2
DOIs
Publication statusPublished - 2009
Event2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009 - Selangor
Duration: 5 Aug 20097 Aug 2009

Other

Other2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009
CitySelangor
Period5/8/097/8/09

Fingerprint

Passive optical networks
Fault detection
Reflectometers
Monitoring
Testing
Personnel
Network performance
Ethernet
Testbeds
Light sources
Networks (circuits)
Lasers
Costs

Keywords

  • Advanced data analyzing
  • Centralized monitoring
  • Network performance
  • OTDR
  • Remote PC

ASJC Scopus subject areas

  • Information Systems
  • Software
  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Chuan, N. B., Ab Rahman, M. S., Premadi, A., & Jumari, K. (2009). Application of SANTAD in network monitoring and fault detection of FTTH-PON. In Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009 (Vol. 2, pp. 453-458). [5254695] https://doi.org/10.1109/ICEEI.2009.5254695

Application of SANTAD in network monitoring and fault detection of FTTH-PON. / Chuan, Ng Boon; Ab Rahman, Mohd Syuhaimi; Premadi, Aswir; Jumari, Kasmiran.

Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 2 2009. p. 453-458 5254695.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Chuan, NB, Ab Rahman, MS, Premadi, A & Jumari, K 2009, Application of SANTAD in network monitoring and fault detection of FTTH-PON. in Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. vol. 2, 5254695, pp. 453-458, 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009, Selangor, 5/8/09. https://doi.org/10.1109/ICEEI.2009.5254695
Chuan NB, Ab Rahman MS, Premadi A, Jumari K. Application of SANTAD in network monitoring and fault detection of FTTH-PON. In Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 2. 2009. p. 453-458. 5254695 https://doi.org/10.1109/ICEEI.2009.5254695
Chuan, Ng Boon ; Ab Rahman, Mohd Syuhaimi ; Premadi, Aswir ; Jumari, Kasmiran. / Application of SANTAD in network monitoring and fault detection of FTTH-PON. Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 2 2009. pp. 453-458
@inproceedings{1c4a70a7edc6485da2edb6425c8957cd,
title = "Application of SANTAD in network monitoring and fault detection of FTTH-PON",
abstract = "This paper presented a new approach to monitor the network performance and detect any occurrence of fault in fiberto- the-home passive optical network (FTTH-PON) using an efficient monitoring system named Smart Access Network-Testing, Analyzing and Database (SANTAD). An optical time domain reflectometer (OTDR) with 1625 nm laser source is located at central office (CO) and connected to a remote personnel computer (PC) via Ethernet TCP/IP connection. A tapper circuit is designed to allow the OTDR testing signal to bypass the optical splitter in a conventional FTTH-PON when emitted in downstream direction. The key idea is to accumulate all OTDR measurement to be displayed on a PC computer screen for centralized monitoring and advanced data analyzing. The main advantages of this work is to improve the survivability and efficiency of FTTH-PON, while reduce the hands on workload as well as maintenance cost and time. The proposed system was implemented in a FTTH-PON network testbed and the experimental results showed that the proposed system achieves high accuracy in addressing the exact failure location.",
keywords = "Advanced data analyzing, Centralized monitoring, Network performance, OTDR, Remote PC",
author = "Chuan, {Ng Boon} and {Ab Rahman}, {Mohd Syuhaimi} and Aswir Premadi and Kasmiran Jumari",
year = "2009",
doi = "10.1109/ICEEI.2009.5254695",
language = "English",
isbn = "9781424449132",
volume = "2",
pages = "453--458",
booktitle = "Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009",

}

TY - GEN

T1 - Application of SANTAD in network monitoring and fault detection of FTTH-PON

AU - Chuan, Ng Boon

AU - Ab Rahman, Mohd Syuhaimi

AU - Premadi, Aswir

AU - Jumari, Kasmiran

PY - 2009

Y1 - 2009

N2 - This paper presented a new approach to monitor the network performance and detect any occurrence of fault in fiberto- the-home passive optical network (FTTH-PON) using an efficient monitoring system named Smart Access Network-Testing, Analyzing and Database (SANTAD). An optical time domain reflectometer (OTDR) with 1625 nm laser source is located at central office (CO) and connected to a remote personnel computer (PC) via Ethernet TCP/IP connection. A tapper circuit is designed to allow the OTDR testing signal to bypass the optical splitter in a conventional FTTH-PON when emitted in downstream direction. The key idea is to accumulate all OTDR measurement to be displayed on a PC computer screen for centralized monitoring and advanced data analyzing. The main advantages of this work is to improve the survivability and efficiency of FTTH-PON, while reduce the hands on workload as well as maintenance cost and time. The proposed system was implemented in a FTTH-PON network testbed and the experimental results showed that the proposed system achieves high accuracy in addressing the exact failure location.

AB - This paper presented a new approach to monitor the network performance and detect any occurrence of fault in fiberto- the-home passive optical network (FTTH-PON) using an efficient monitoring system named Smart Access Network-Testing, Analyzing and Database (SANTAD). An optical time domain reflectometer (OTDR) with 1625 nm laser source is located at central office (CO) and connected to a remote personnel computer (PC) via Ethernet TCP/IP connection. A tapper circuit is designed to allow the OTDR testing signal to bypass the optical splitter in a conventional FTTH-PON when emitted in downstream direction. The key idea is to accumulate all OTDR measurement to be displayed on a PC computer screen for centralized monitoring and advanced data analyzing. The main advantages of this work is to improve the survivability and efficiency of FTTH-PON, while reduce the hands on workload as well as maintenance cost and time. The proposed system was implemented in a FTTH-PON network testbed and the experimental results showed that the proposed system achieves high accuracy in addressing the exact failure location.

KW - Advanced data analyzing

KW - Centralized monitoring

KW - Network performance

KW - OTDR

KW - Remote PC

UR - http://www.scopus.com/inward/record.url?scp=70449670955&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449670955&partnerID=8YFLogxK

U2 - 10.1109/ICEEI.2009.5254695

DO - 10.1109/ICEEI.2009.5254695

M3 - Conference contribution

SN - 9781424449132

VL - 2

SP - 453

EP - 458

BT - Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009

ER -