Analysis of transcutaneous inductive powering links

Saad Mutashar, Hannan M A, Salina Abdul Samad, Aini Hussain

Research output: Chapter in Book/Report/Conference proceedingConference contribution

9 Citations (Scopus)

Abstract

Inductive coupling link is widely used in transcutaneous power transmission to transfer data and power to the implanted biomedical devices such as implanted micro-sensor system. The inductive coupling variables play a strong rule in coupling efficiency. In this paper the coupling link variables is investigated and analyzed. The resonant frequency 13.56 MHz was used according to industrial, scientific and medical (ISM) band. Results show that the voltage gain V gain of the inductive links is depended of coupling factor K and resistive load R load (implanted device). The voltage gain increase with increasing the implanted resistance with constant K. Simulation show that when R load400Ω, the V gain will be in maximum value, and when R load200Ω, the V gain will be in minimum value and approximately 4v. With these results, the system operation is satisfied the requirement of the implanted devices power. Theoretical and simulation is done using software OrCAD-P spice 16.2.

Original languageEnglish
Title of host publicationICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings
Pages64-67
Number of pages4
Volume1
DOIs
Publication statusPublished - 2012
Event2012 4th International Conference on Intelligent and Advanced Systems, ICIAS 2012 - Kuala Lumpur
Duration: 12 Jun 201214 Jun 2012

Other

Other2012 4th International Conference on Intelligent and Advanced Systems, ICIAS 2012
CityKuala Lumpur
Period12/6/1214/6/12

Fingerprint

Electric potential
Data transfer
Power transmission
Natural frequencies
Sensors

Keywords

  • Biomedical implanted devices
  • energy harvesting
  • inductive coupling links
  • Low band frequency (ISM)

ASJC Scopus subject areas

  • Artificial Intelligence
  • Information Systems

Cite this

Mutashar, S., M A, H., Abdul Samad, S., & Hussain, A. (2012). Analysis of transcutaneous inductive powering links. In ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings (Vol. 1, pp. 64-67). [6306160] https://doi.org/10.1109/ICIAS.2012.6306160

Analysis of transcutaneous inductive powering links. / Mutashar, Saad; M A, Hannan; Abdul Samad, Salina; Hussain, Aini.

ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings. Vol. 1 2012. p. 64-67 6306160.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Mutashar, S, M A, H, Abdul Samad, S & Hussain, A 2012, Analysis of transcutaneous inductive powering links. in ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings. vol. 1, 6306160, pp. 64-67, 2012 4th International Conference on Intelligent and Advanced Systems, ICIAS 2012, Kuala Lumpur, 12/6/12. https://doi.org/10.1109/ICIAS.2012.6306160
Mutashar S, M A H, Abdul Samad S, Hussain A. Analysis of transcutaneous inductive powering links. In ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings. Vol. 1. 2012. p. 64-67. 6306160 https://doi.org/10.1109/ICIAS.2012.6306160
Mutashar, Saad ; M A, Hannan ; Abdul Samad, Salina ; Hussain, Aini. / Analysis of transcutaneous inductive powering links. ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings. Vol. 1 2012. pp. 64-67
@inproceedings{ab30a3f578ec4c3187147b52a1a38820,
title = "Analysis of transcutaneous inductive powering links",
abstract = "Inductive coupling link is widely used in transcutaneous power transmission to transfer data and power to the implanted biomedical devices such as implanted micro-sensor system. The inductive coupling variables play a strong rule in coupling efficiency. In this paper the coupling link variables is investigated and analyzed. The resonant frequency 13.56 MHz was used according to industrial, scientific and medical (ISM) band. Results show that the voltage gain V gain of the inductive links is depended of coupling factor K and resistive load R load (implanted device). The voltage gain increase with increasing the implanted resistance with constant K. Simulation show that when R load400Ω, the V gain will be in maximum value, and when R load200Ω, the V gain will be in minimum value and approximately 4v. With these results, the system operation is satisfied the requirement of the implanted devices power. Theoretical and simulation is done using software OrCAD-P spice 16.2.",
keywords = "Biomedical implanted devices, energy harvesting, inductive coupling links, Low band frequency (ISM)",
author = "Saad Mutashar and {M A}, Hannan and {Abdul Samad}, Salina and Aini Hussain",
year = "2012",
doi = "10.1109/ICIAS.2012.6306160",
language = "English",
isbn = "9781457719677",
volume = "1",
pages = "64--67",
booktitle = "ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings",

}

TY - GEN

T1 - Analysis of transcutaneous inductive powering links

AU - Mutashar, Saad

AU - M A, Hannan

AU - Abdul Samad, Salina

AU - Hussain, Aini

PY - 2012

Y1 - 2012

N2 - Inductive coupling link is widely used in transcutaneous power transmission to transfer data and power to the implanted biomedical devices such as implanted micro-sensor system. The inductive coupling variables play a strong rule in coupling efficiency. In this paper the coupling link variables is investigated and analyzed. The resonant frequency 13.56 MHz was used according to industrial, scientific and medical (ISM) band. Results show that the voltage gain V gain of the inductive links is depended of coupling factor K and resistive load R load (implanted device). The voltage gain increase with increasing the implanted resistance with constant K. Simulation show that when R load400Ω, the V gain will be in maximum value, and when R load200Ω, the V gain will be in minimum value and approximately 4v. With these results, the system operation is satisfied the requirement of the implanted devices power. Theoretical and simulation is done using software OrCAD-P spice 16.2.

AB - Inductive coupling link is widely used in transcutaneous power transmission to transfer data and power to the implanted biomedical devices such as implanted micro-sensor system. The inductive coupling variables play a strong rule in coupling efficiency. In this paper the coupling link variables is investigated and analyzed. The resonant frequency 13.56 MHz was used according to industrial, scientific and medical (ISM) band. Results show that the voltage gain V gain of the inductive links is depended of coupling factor K and resistive load R load (implanted device). The voltage gain increase with increasing the implanted resistance with constant K. Simulation show that when R load400Ω, the V gain will be in maximum value, and when R load200Ω, the V gain will be in minimum value and approximately 4v. With these results, the system operation is satisfied the requirement of the implanted devices power. Theoretical and simulation is done using software OrCAD-P spice 16.2.

KW - Biomedical implanted devices

KW - energy harvesting

KW - inductive coupling links

KW - Low band frequency (ISM)

UR - http://www.scopus.com/inward/record.url?scp=84867947446&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84867947446&partnerID=8YFLogxK

U2 - 10.1109/ICIAS.2012.6306160

DO - 10.1109/ICIAS.2012.6306160

M3 - Conference contribution

AN - SCOPUS:84867947446

SN - 9781457719677

VL - 1

SP - 64

EP - 67

BT - ICIAS 2012 - 2012 4th International Conference on Intelligent and Advanced Systems: A Conference of World Engineering, Science and Technology Congress (ESTCON) - Conference Proceedings