An improved three-phase reactive power measurement algorithm using walsh functions transform

Garba Aliyu, Saifulnizam Bin Abd Khalid, Mohd Wazir Mustafa, Hussein Shareef

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

This paper proposes an improved algorithm for three-phase power component measurement using the Walsh function (WF), which takes into account the advantages offered by the algorithm in the analysis of nonlinear load problems to improve the accuracy and reliability of measurement. In the pricing of electricity based on the value of the integral of the load active power measured using a kilowatt-hour meter, the electric utility loses some revenue for the energy delivered to current harmonic generating customers and customers whose load causes current asymmetry. An improved algorithm based on the WF for measuring the active and reactive power of a network with linear and or nonlinear and sinusoidal or nonsinusoidal network is developed and tested, and the result compared with IEEE standard 1459-2000 which is based on fast Fourier transformation. The method does not require phase shifting of the phase current signals by π/2 with respect to the voltage signals. The proposed algorithm enables reactive power measurement for proper electricity billing to the consumer with nonlinear loads.

Original languageEnglish
Pages (from-to)7-14
Number of pages8
JournalIEEJ Transactions on Electrical and Electronic Engineering
Volume9
Issue number1
DOIs
Publication statusPublished - Jan 2014
Externally publishedYes

Fingerprint

Reactive power
Electricity
Electric utilities
Electric potential
Costs

Keywords

  • Accurate measurement
  • Electricity billing
  • Reactive power
  • Walsh function

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

An improved three-phase reactive power measurement algorithm using walsh functions transform. / Aliyu, Garba; Khalid, Saifulnizam Bin Abd; Mustafa, Mohd Wazir; Shareef, Hussein.

In: IEEJ Transactions on Electrical and Electronic Engineering, Vol. 9, No. 1, 01.2014, p. 7-14.

Research output: Contribution to journalArticle

Aliyu, Garba ; Khalid, Saifulnizam Bin Abd ; Mustafa, Mohd Wazir ; Shareef, Hussein. / An improved three-phase reactive power measurement algorithm using walsh functions transform. In: IEEJ Transactions on Electrical and Electronic Engineering. 2014 ; Vol. 9, No. 1. pp. 7-14.
@article{9cff3dc636f645b98f5d6fc9e8d49061,
title = "An improved three-phase reactive power measurement algorithm using walsh functions transform",
abstract = "This paper proposes an improved algorithm for three-phase power component measurement using the Walsh function (WF), which takes into account the advantages offered by the algorithm in the analysis of nonlinear load problems to improve the accuracy and reliability of measurement. In the pricing of electricity based on the value of the integral of the load active power measured using a kilowatt-hour meter, the electric utility loses some revenue for the energy delivered to current harmonic generating customers and customers whose load causes current asymmetry. An improved algorithm based on the WF for measuring the active and reactive power of a network with linear and or nonlinear and sinusoidal or nonsinusoidal network is developed and tested, and the result compared with IEEE standard 1459-2000 which is based on fast Fourier transformation. The method does not require phase shifting of the phase current signals by π/2 with respect to the voltage signals. The proposed algorithm enables reactive power measurement for proper electricity billing to the consumer with nonlinear loads.",
keywords = "Accurate measurement, Electricity billing, Reactive power, Walsh function",
author = "Garba Aliyu and Khalid, {Saifulnizam Bin Abd} and Mustafa, {Mohd Wazir} and Hussein Shareef",
year = "2014",
month = "1",
doi = "10.1002/tee.21930",
language = "English",
volume = "9",
pages = "7--14",
journal = "IEEJ Transactions on Electrical and Electronic Engineering",
issn = "1931-4973",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - An improved three-phase reactive power measurement algorithm using walsh functions transform

AU - Aliyu, Garba

AU - Khalid, Saifulnizam Bin Abd

AU - Mustafa, Mohd Wazir

AU - Shareef, Hussein

PY - 2014/1

Y1 - 2014/1

N2 - This paper proposes an improved algorithm for three-phase power component measurement using the Walsh function (WF), which takes into account the advantages offered by the algorithm in the analysis of nonlinear load problems to improve the accuracy and reliability of measurement. In the pricing of electricity based on the value of the integral of the load active power measured using a kilowatt-hour meter, the electric utility loses some revenue for the energy delivered to current harmonic generating customers and customers whose load causes current asymmetry. An improved algorithm based on the WF for measuring the active and reactive power of a network with linear and or nonlinear and sinusoidal or nonsinusoidal network is developed and tested, and the result compared with IEEE standard 1459-2000 which is based on fast Fourier transformation. The method does not require phase shifting of the phase current signals by π/2 with respect to the voltage signals. The proposed algorithm enables reactive power measurement for proper electricity billing to the consumer with nonlinear loads.

AB - This paper proposes an improved algorithm for three-phase power component measurement using the Walsh function (WF), which takes into account the advantages offered by the algorithm in the analysis of nonlinear load problems to improve the accuracy and reliability of measurement. In the pricing of electricity based on the value of the integral of the load active power measured using a kilowatt-hour meter, the electric utility loses some revenue for the energy delivered to current harmonic generating customers and customers whose load causes current asymmetry. An improved algorithm based on the WF for measuring the active and reactive power of a network with linear and or nonlinear and sinusoidal or nonsinusoidal network is developed and tested, and the result compared with IEEE standard 1459-2000 which is based on fast Fourier transformation. The method does not require phase shifting of the phase current signals by π/2 with respect to the voltage signals. The proposed algorithm enables reactive power measurement for proper electricity billing to the consumer with nonlinear loads.

KW - Accurate measurement

KW - Electricity billing

KW - Reactive power

KW - Walsh function

UR - http://www.scopus.com/inward/record.url?scp=84889645098&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84889645098&partnerID=8YFLogxK

U2 - 10.1002/tee.21930

DO - 10.1002/tee.21930

M3 - Article

VL - 9

SP - 7

EP - 14

JO - IEEJ Transactions on Electrical and Electronic Engineering

JF - IEEJ Transactions on Electrical and Electronic Engineering

SN - 1931-4973

IS - 1

ER -