Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation

Ahmad Farid Bin Abidin, Azah Mohamed

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

A new algorithm for adaptive setting of Zone 3 of distance relays during severe voltage fluctuations is proposed. Conventional relays may mal-operate during under voltage instability condition. The developed algorithm is based on dynamic adjustment of zone 3 setting of distance relays to avoid mal-operation. The proposed algorithm overcomes the pitfall in conventional relays by dynamically changing zone 3 reach setting of the distance relay. The paper describes the new algorithm and presents results obtained from studies on the IEEE 9 bus test system

Original languageEnglish
Title of host publicationProceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011
Pages162-165
Number of pages4
DOIs
Publication statusPublished - 2011
Event2011 IEEE International Conference on System Engineering and Technology, ICSET 2011 - Shah Alam
Duration: 27 Jun 201128 Jun 2011

Other

Other2011 IEEE International Conference on System Engineering and Technology, ICSET 2011
CityShah Alam
Period27/6/1128/6/11

Fingerprint

Electric potential

Keywords

  • Distance Protection
  • Dynamic Adjustment
  • Relay Reach Setting
  • Voltage Instability

ASJC Scopus subject areas

  • Computer Networks and Communications

Cite this

Farid Bin Abidin, A., & Mohamed, A. (2011). Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation. In Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011 (pp. 162-165). [5993442] https://doi.org/10.1109/ICSEngT.2011.5993442

Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation. / Farid Bin Abidin, Ahmad; Mohamed, Azah.

Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011. 2011. p. 162-165 5993442.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Farid Bin Abidin, A & Mohamed, A 2011, Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation. in Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011., 5993442, pp. 162-165, 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011, Shah Alam, 27/6/11. https://doi.org/10.1109/ICSEngT.2011.5993442
Farid Bin Abidin A, Mohamed A. Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation. In Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011. 2011. p. 162-165. 5993442 https://doi.org/10.1109/ICSEngT.2011.5993442
Farid Bin Abidin, Ahmad ; Mohamed, Azah. / Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation. Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011. 2011. pp. 162-165
@inproceedings{661fdf4bef3d411f8823fc76946efbb3,
title = "Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation",
abstract = "A new algorithm for adaptive setting of Zone 3 of distance relays during severe voltage fluctuations is proposed. Conventional relays may mal-operate during under voltage instability condition. The developed algorithm is based on dynamic adjustment of zone 3 setting of distance relays to avoid mal-operation. The proposed algorithm overcomes the pitfall in conventional relays by dynamically changing zone 3 reach setting of the distance relay. The paper describes the new algorithm and presents results obtained from studies on the IEEE 9 bus test system",
keywords = "Distance Protection, Dynamic Adjustment, Relay Reach Setting, Voltage Instability",
author = "{Farid Bin Abidin}, Ahmad and Azah Mohamed",
year = "2011",
doi = "10.1109/ICSEngT.2011.5993442",
language = "English",
isbn = "9781457712562",
pages = "162--165",
booktitle = "Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011",

}

TY - GEN

T1 - Adaptive settings of distance protection to prevent mal-operation under severe voltage fluctuation

AU - Farid Bin Abidin, Ahmad

AU - Mohamed, Azah

PY - 2011

Y1 - 2011

N2 - A new algorithm for adaptive setting of Zone 3 of distance relays during severe voltage fluctuations is proposed. Conventional relays may mal-operate during under voltage instability condition. The developed algorithm is based on dynamic adjustment of zone 3 setting of distance relays to avoid mal-operation. The proposed algorithm overcomes the pitfall in conventional relays by dynamically changing zone 3 reach setting of the distance relay. The paper describes the new algorithm and presents results obtained from studies on the IEEE 9 bus test system

AB - A new algorithm for adaptive setting of Zone 3 of distance relays during severe voltage fluctuations is proposed. Conventional relays may mal-operate during under voltage instability condition. The developed algorithm is based on dynamic adjustment of zone 3 setting of distance relays to avoid mal-operation. The proposed algorithm overcomes the pitfall in conventional relays by dynamically changing zone 3 reach setting of the distance relay. The paper describes the new algorithm and presents results obtained from studies on the IEEE 9 bus test system

KW - Distance Protection

KW - Dynamic Adjustment

KW - Relay Reach Setting

KW - Voltage Instability

UR - http://www.scopus.com/inward/record.url?scp=80052825585&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052825585&partnerID=8YFLogxK

U2 - 10.1109/ICSEngT.2011.5993442

DO - 10.1109/ICSEngT.2011.5993442

M3 - Conference contribution

SN - 9781457712562

SP - 162

EP - 165

BT - Proceedings - 2011 IEEE International Conference on System Engineering and Technology, ICSET 2011

ER -