Absorbed dose to water intercomparison programme for radiotherapy centres

Supian Samat, S. X. Too, T. Kadni, M. T. Dolah

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The importance of intercomparison programme for radiation therapy dose delivery at radiotherapy centres (RC) has widely been reported. We at Nuclear Malaysia Agency (NM) intend to develop a national level intercomparison programme in terms of absorbed dose to water Dw. We started with one RC which has volunteered to participate in the programme in the dose delivery of 6 MV x-ray beam. Two types of comparison were made to get the accuracy. Type I is based on the measured value of the Dw at reference depth, Dw(zref)mea: RC results was compared with NM, in which the NM result was taken as a standard. Type II is based on calculated value the Dw(zref), Dw(zref)cal: both NM and RC results were compared with Dw(zref)cal, in which Dw(zref)cal was taken as a standard. Two on-site measurements were made at this centre to check for results consistency and to get the average accuracy. Results obtained were consistent for the two measurements and the average values in the accuracy are within the acceptable accuracy limit of ± 3%, namely Type I: 1.10 ± 0.58% for the RC, and Type II: 0.99 ± 0.60% and -0.11 ± 0.26% respectively for the RC and NM.

Original languageEnglish
Pages (from-to)197-202
Number of pages6
JournalSains Malaysiana
Volume38
Issue number2
Publication statusPublished - Apr 2009

Fingerprint

Malaysia
radiation therapy
dosage
water
delivery
x rays

Keywords

  • Absorbed dose to water
  • Intercomparison programme
  • Radiotherapy centres

ASJC Scopus subject areas

  • General

Cite this

Samat, S., Too, S. X., Kadni, T., & Dolah, M. T. (2009). Absorbed dose to water intercomparison programme for radiotherapy centres. Sains Malaysiana, 38(2), 197-202.

Absorbed dose to water intercomparison programme for radiotherapy centres. / Samat, Supian; Too, S. X.; Kadni, T.; Dolah, M. T.

In: Sains Malaysiana, Vol. 38, No. 2, 04.2009, p. 197-202.

Research output: Contribution to journalArticle

Samat, S, Too, SX, Kadni, T & Dolah, MT 2009, 'Absorbed dose to water intercomparison programme for radiotherapy centres', Sains Malaysiana, vol. 38, no. 2, pp. 197-202.
Samat, Supian ; Too, S. X. ; Kadni, T. ; Dolah, M. T. / Absorbed dose to water intercomparison programme for radiotherapy centres. In: Sains Malaysiana. 2009 ; Vol. 38, No. 2. pp. 197-202.
@article{ad03625da401493f8329515229a93ec5,
title = "Absorbed dose to water intercomparison programme for radiotherapy centres",
abstract = "The importance of intercomparison programme for radiation therapy dose delivery at radiotherapy centres (RC) has widely been reported. We at Nuclear Malaysia Agency (NM) intend to develop a national level intercomparison programme in terms of absorbed dose to water Dw. We started with one RC which has volunteered to participate in the programme in the dose delivery of 6 MV x-ray beam. Two types of comparison were made to get the accuracy. Type I is based on the measured value of the Dw at reference depth, Dw(zref)mea: RC results was compared with NM, in which the NM result was taken as a standard. Type II is based on calculated value the Dw(zref), Dw(zref)cal: both NM and RC results were compared with Dw(zref)cal, in which Dw(zref)cal was taken as a standard. Two on-site measurements were made at this centre to check for results consistency and to get the average accuracy. Results obtained were consistent for the two measurements and the average values in the accuracy are within the acceptable accuracy limit of ± 3{\%}, namely Type I: 1.10 ± 0.58{\%} for the RC, and Type II: 0.99 ± 0.60{\%} and -0.11 ± 0.26{\%} respectively for the RC and NM.",
keywords = "Absorbed dose to water, Intercomparison programme, Radiotherapy centres",
author = "Supian Samat and Too, {S. X.} and T. Kadni and Dolah, {M. T.}",
year = "2009",
month = "4",
language = "English",
volume = "38",
pages = "197--202",
journal = "Sains Malaysiana",
issn = "0126-6039",
publisher = "Penerbit Universiti Kebangsaan Malaysia",
number = "2",

}

TY - JOUR

T1 - Absorbed dose to water intercomparison programme for radiotherapy centres

AU - Samat, Supian

AU - Too, S. X.

AU - Kadni, T.

AU - Dolah, M. T.

PY - 2009/4

Y1 - 2009/4

N2 - The importance of intercomparison programme for radiation therapy dose delivery at radiotherapy centres (RC) has widely been reported. We at Nuclear Malaysia Agency (NM) intend to develop a national level intercomparison programme in terms of absorbed dose to water Dw. We started with one RC which has volunteered to participate in the programme in the dose delivery of 6 MV x-ray beam. Two types of comparison were made to get the accuracy. Type I is based on the measured value of the Dw at reference depth, Dw(zref)mea: RC results was compared with NM, in which the NM result was taken as a standard. Type II is based on calculated value the Dw(zref), Dw(zref)cal: both NM and RC results were compared with Dw(zref)cal, in which Dw(zref)cal was taken as a standard. Two on-site measurements were made at this centre to check for results consistency and to get the average accuracy. Results obtained were consistent for the two measurements and the average values in the accuracy are within the acceptable accuracy limit of ± 3%, namely Type I: 1.10 ± 0.58% for the RC, and Type II: 0.99 ± 0.60% and -0.11 ± 0.26% respectively for the RC and NM.

AB - The importance of intercomparison programme for radiation therapy dose delivery at radiotherapy centres (RC) has widely been reported. We at Nuclear Malaysia Agency (NM) intend to develop a national level intercomparison programme in terms of absorbed dose to water Dw. We started with one RC which has volunteered to participate in the programme in the dose delivery of 6 MV x-ray beam. Two types of comparison were made to get the accuracy. Type I is based on the measured value of the Dw at reference depth, Dw(zref)mea: RC results was compared with NM, in which the NM result was taken as a standard. Type II is based on calculated value the Dw(zref), Dw(zref)cal: both NM and RC results were compared with Dw(zref)cal, in which Dw(zref)cal was taken as a standard. Two on-site measurements were made at this centre to check for results consistency and to get the average accuracy. Results obtained were consistent for the two measurements and the average values in the accuracy are within the acceptable accuracy limit of ± 3%, namely Type I: 1.10 ± 0.58% for the RC, and Type II: 0.99 ± 0.60% and -0.11 ± 0.26% respectively for the RC and NM.

KW - Absorbed dose to water

KW - Intercomparison programme

KW - Radiotherapy centres

UR - http://www.scopus.com/inward/record.url?scp=65449185525&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=65449185525&partnerID=8YFLogxK

M3 - Article

VL - 38

SP - 197

EP - 202

JO - Sains Malaysiana

JF - Sains Malaysiana

SN - 0126-6039

IS - 2