A solid-state pH transducer fabricated from a self-plasticized methacrylic-acrylic membrane for potentiometric acetylcholine chloride biosensor

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A solid-state pH sensor based on a self-plasticizing film of methacrylic-acrylic copolymer was developed. The sensor was able to detect changes in pH after tridodecylamine ionophore was immobilized together with a lipophilic anionic salt. The pH sensor exhibited almost a Nemstian response (57.6 mV pH-1) with a linear pH response range of 6-10. It demonstrated a fast response (<2 min) to changes in pH and good selectivity against other common cations such as sodium, potassium, magnesium, lithium, and calcium. The sensor has a shelf life of at least 30 days without an obvious deterioration in response. By depositing a layer of poly(hydroxylethymethacrylate) immobilized with enzyme acetylcholinesterase on top of the pH selective methacrylic-acrylic film, the pH sensor was able to detect acetylcholine chloride (AChCl). The linear response range of the potentiometric biosensor to AChCl was dependent on the buffer concentrations used, and for a buffer concentration less than 1 mM, the linear response range obtained was 3.98-31.62 μM.

Original languageEnglish
Pages (from-to)884-888
Number of pages5
JournalJournal of Analytical Chemistry
Volume62
Issue number9
DOIs
Publication statusPublished - Sep 2007

Fingerprint

pH sensors
Biosensors
Acetylcholine
Acrylics
Transducers
Membranes
Buffers
Solid-state sensors
Ionophores
Sensors
Acetylcholinesterase
Lithium
Magnesium
Deterioration
Cations
Potassium
Copolymers
Salts
Sodium
Calcium

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

@article{34c7d5cbf71d4d0eb74f1d2cea7d8bc0,
title = "A solid-state pH transducer fabricated from a self-plasticized methacrylic-acrylic membrane for potentiometric acetylcholine chloride biosensor",
abstract = "A solid-state pH sensor based on a self-plasticizing film of methacrylic-acrylic copolymer was developed. The sensor was able to detect changes in pH after tridodecylamine ionophore was immobilized together with a lipophilic anionic salt. The pH sensor exhibited almost a Nemstian response (57.6 mV pH-1) with a linear pH response range of 6-10. It demonstrated a fast response (<2 min) to changes in pH and good selectivity against other common cations such as sodium, potassium, magnesium, lithium, and calcium. The sensor has a shelf life of at least 30 days without an obvious deterioration in response. By depositing a layer of poly(hydroxylethymethacrylate) immobilized with enzyme acetylcholinesterase on top of the pH selective methacrylic-acrylic film, the pH sensor was able to detect acetylcholine chloride (AChCl). The linear response range of the potentiometric biosensor to AChCl was dependent on the buffer concentrations used, and for a buffer concentration less than 1 mM, the linear response range obtained was 3.98-31.62 μM.",
author = "Peng, {L. B.} and Lee, {Yook Heng} and Hasbullah, {Siti Aishah} and Musa Ahmad",
year = "2007",
month = "9",
doi = "10.1134/S1061934807090146",
language = "English",
volume = "62",
pages = "884--888",
journal = "Journal of Analytical Chemistry",
issn = "1061-9348",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "9",

}

TY - JOUR

T1 - A solid-state pH transducer fabricated from a self-plasticized methacrylic-acrylic membrane for potentiometric acetylcholine chloride biosensor

AU - Peng, L. B.

AU - Lee, Yook Heng

AU - Hasbullah, Siti Aishah

AU - Ahmad, Musa

PY - 2007/9

Y1 - 2007/9

N2 - A solid-state pH sensor based on a self-plasticizing film of methacrylic-acrylic copolymer was developed. The sensor was able to detect changes in pH after tridodecylamine ionophore was immobilized together with a lipophilic anionic salt. The pH sensor exhibited almost a Nemstian response (57.6 mV pH-1) with a linear pH response range of 6-10. It demonstrated a fast response (<2 min) to changes in pH and good selectivity against other common cations such as sodium, potassium, magnesium, lithium, and calcium. The sensor has a shelf life of at least 30 days without an obvious deterioration in response. By depositing a layer of poly(hydroxylethymethacrylate) immobilized with enzyme acetylcholinesterase on top of the pH selective methacrylic-acrylic film, the pH sensor was able to detect acetylcholine chloride (AChCl). The linear response range of the potentiometric biosensor to AChCl was dependent on the buffer concentrations used, and for a buffer concentration less than 1 mM, the linear response range obtained was 3.98-31.62 μM.

AB - A solid-state pH sensor based on a self-plasticizing film of methacrylic-acrylic copolymer was developed. The sensor was able to detect changes in pH after tridodecylamine ionophore was immobilized together with a lipophilic anionic salt. The pH sensor exhibited almost a Nemstian response (57.6 mV pH-1) with a linear pH response range of 6-10. It demonstrated a fast response (<2 min) to changes in pH and good selectivity against other common cations such as sodium, potassium, magnesium, lithium, and calcium. The sensor has a shelf life of at least 30 days without an obvious deterioration in response. By depositing a layer of poly(hydroxylethymethacrylate) immobilized with enzyme acetylcholinesterase on top of the pH selective methacrylic-acrylic film, the pH sensor was able to detect acetylcholine chloride (AChCl). The linear response range of the potentiometric biosensor to AChCl was dependent on the buffer concentrations used, and for a buffer concentration less than 1 mM, the linear response range obtained was 3.98-31.62 μM.

UR - http://www.scopus.com/inward/record.url?scp=34548413168&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34548413168&partnerID=8YFLogxK

U2 - 10.1134/S1061934807090146

DO - 10.1134/S1061934807090146

M3 - Article

VL - 62

SP - 884

EP - 888

JO - Journal of Analytical Chemistry

JF - Journal of Analytical Chemistry

SN - 1061-9348

IS - 9