A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty

Thian Seng Lee, Indra Mohd Zin, Abdul Yazid Mohd Kassim, Suhail Abdullah, Riza Sulaiman

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper presents a technique to measure and select the most suitable size of humeral head implant during preoperating planning phase in shoulder hemiarthroplasty surgery. The purpose of this work is to develop a standard methodology to be applied specifically in digital templating software for shoulder hemiarthroplasty surgery. The framework of the technique is described in this article to give an overview of the new technique. The technique proposed was applied in a new digital templating application named Ortho Shoulder by using Visual C++ programming tool. The application developed has been tested by a few orthopedic surgeons and excellent responses were obtained.

Original languageEnglish
Title of host publicationProceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009
Pages190-193
Number of pages4
Volume1
DOIs
Publication statusPublished - 2009
Event2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009 - Selangor
Duration: 5 Aug 20097 Aug 2009

Other

Other2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009
CitySelangor
Period5/8/097/8/09

Fingerprint

Arthroplasty
Surgery
Orthopedics
Planning

Keywords

  • Digital templating
  • Preoperative planning
  • Shoulder hemiarthroplasty
  • Total shoulder arthroplasty

ASJC Scopus subject areas

  • Information Systems
  • Software
  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Lee, T. S., Zin, I. M., Mohd Kassim, A. Y., Abdullah, S., & Sulaiman, R. (2009). A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty. In Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009 (Vol. 1, pp. 190-193). [5254794] https://doi.org/10.1109/ICEEI.2009.5254794

A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty. / Lee, Thian Seng; Zin, Indra Mohd; Mohd Kassim, Abdul Yazid; Abdullah, Suhail; Sulaiman, Riza.

Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 1 2009. p. 190-193 5254794.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lee, TS, Zin, IM, Mohd Kassim, AY, Abdullah, S & Sulaiman, R 2009, A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty. in Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. vol. 1, 5254794, pp. 190-193, 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009, Selangor, 5/8/09. https://doi.org/10.1109/ICEEI.2009.5254794
Lee TS, Zin IM, Mohd Kassim AY, Abdullah S, Sulaiman R. A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty. In Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 1. 2009. p. 190-193. 5254794 https://doi.org/10.1109/ICEEI.2009.5254794
Lee, Thian Seng ; Zin, Indra Mohd ; Mohd Kassim, Abdul Yazid ; Abdullah, Suhail ; Sulaiman, Riza. / A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty. Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009. Vol. 1 2009. pp. 190-193
@inproceedings{9f386e4633294d659c25bc01c5f84f5e,
title = "A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty",
abstract = "This paper presents a technique to measure and select the most suitable size of humeral head implant during preoperating planning phase in shoulder hemiarthroplasty surgery. The purpose of this work is to develop a standard methodology to be applied specifically in digital templating software for shoulder hemiarthroplasty surgery. The framework of the technique is described in this article to give an overview of the new technique. The technique proposed was applied in a new digital templating application named Ortho Shoulder by using Visual C++ programming tool. The application developed has been tested by a few orthopedic surgeons and excellent responses were obtained.",
keywords = "Digital templating, Preoperative planning, Shoulder hemiarthroplasty, Total shoulder arthroplasty",
author = "Lee, {Thian Seng} and Zin, {Indra Mohd} and {Mohd Kassim}, {Abdul Yazid} and Suhail Abdullah and Riza Sulaiman",
year = "2009",
doi = "10.1109/ICEEI.2009.5254794",
language = "English",
isbn = "9781424449132",
volume = "1",
pages = "190--193",
booktitle = "Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009",

}

TY - GEN

T1 - A simple and efficient technique for humeral head implant selection during preoperative digital templating phase in shoulder arthroplasty

AU - Lee, Thian Seng

AU - Zin, Indra Mohd

AU - Mohd Kassim, Abdul Yazid

AU - Abdullah, Suhail

AU - Sulaiman, Riza

PY - 2009

Y1 - 2009

N2 - This paper presents a technique to measure and select the most suitable size of humeral head implant during preoperating planning phase in shoulder hemiarthroplasty surgery. The purpose of this work is to develop a standard methodology to be applied specifically in digital templating software for shoulder hemiarthroplasty surgery. The framework of the technique is described in this article to give an overview of the new technique. The technique proposed was applied in a new digital templating application named Ortho Shoulder by using Visual C++ programming tool. The application developed has been tested by a few orthopedic surgeons and excellent responses were obtained.

AB - This paper presents a technique to measure and select the most suitable size of humeral head implant during preoperating planning phase in shoulder hemiarthroplasty surgery. The purpose of this work is to develop a standard methodology to be applied specifically in digital templating software for shoulder hemiarthroplasty surgery. The framework of the technique is described in this article to give an overview of the new technique. The technique proposed was applied in a new digital templating application named Ortho Shoulder by using Visual C++ programming tool. The application developed has been tested by a few orthopedic surgeons and excellent responses were obtained.

KW - Digital templating

KW - Preoperative planning

KW - Shoulder hemiarthroplasty

KW - Total shoulder arthroplasty

UR - http://www.scopus.com/inward/record.url?scp=70449635709&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449635709&partnerID=8YFLogxK

U2 - 10.1109/ICEEI.2009.5254794

DO - 10.1109/ICEEI.2009.5254794

M3 - Conference contribution

SN - 9781424449132

VL - 1

SP - 190

EP - 193

BT - Proceedings of the 2009 International Conference on Electrical Engineering and Informatics, ICEEI 2009

ER -