A novel voltage sag source detection method using TFR technique

Mohamed F. Faisa, Azah Mohamed, Hussain Shareef

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Voltage sag is considered as the major power quality disturbance that can disrupt the operation of sensitive equipment. Many power utilities around the world install power quality recorders at strategic sites to monitor the frequency and severity of voltage sags that may affect their customers. The immediate identification of sources of voltage sags is very critical in providing information to customers to resume back their operations. The sources of voltage sags can originate either from upstream or downstream with respect to the monitoring point. This paper presents a novel method to identify the sources of voltage sags using a signal processing technique called the S-transform (ST). An index named S-Transform Disturbance Power (STDP) was developed to identify the origin of the voltage sags. The results of this study showed that the novel method is superior to the other methods in detecting the origin of both symmetrical and asymmetrical voltage sag in actual power systems.

Original languageEnglish
Pages (from-to)2301-2309
Number of pages9
JournalInternational Review of Electrical Engineering
Volume5
Issue number5
Publication statusPublished - Sep 2010

Fingerprint

Electric potential
Power quality
Mathematical transformations
Signal processing
Monitoring

Keywords

  • Power quality
  • S-transform
  • Signal processing
  • Sources of voltage sags

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

A novel voltage sag source detection method using TFR technique. / Faisa, Mohamed F.; Mohamed, Azah; Shareef, Hussain.

In: International Review of Electrical Engineering, Vol. 5, No. 5, 09.2010, p. 2301-2309.

Research output: Contribution to journalArticle

Faisa, MF, Mohamed, A & Shareef, H 2010, 'A novel voltage sag source detection method using TFR technique', International Review of Electrical Engineering, vol. 5, no. 5, pp. 2301-2309.
Faisa, Mohamed F. ; Mohamed, Azah ; Shareef, Hussain. / A novel voltage sag source detection method using TFR technique. In: International Review of Electrical Engineering. 2010 ; Vol. 5, No. 5. pp. 2301-2309.
@article{9185e99c59a0497b9d3800988d8bd9a2,
title = "A novel voltage sag source detection method using TFR technique",
abstract = "Voltage sag is considered as the major power quality disturbance that can disrupt the operation of sensitive equipment. Many power utilities around the world install power quality recorders at strategic sites to monitor the frequency and severity of voltage sags that may affect their customers. The immediate identification of sources of voltage sags is very critical in providing information to customers to resume back their operations. The sources of voltage sags can originate either from upstream or downstream with respect to the monitoring point. This paper presents a novel method to identify the sources of voltage sags using a signal processing technique called the S-transform (ST). An index named S-Transform Disturbance Power (STDP) was developed to identify the origin of the voltage sags. The results of this study showed that the novel method is superior to the other methods in detecting the origin of both symmetrical and asymmetrical voltage sag in actual power systems.",
keywords = "Power quality, S-transform, Signal processing, Sources of voltage sags",
author = "Faisa, {Mohamed F.} and Azah Mohamed and Hussain Shareef",
year = "2010",
month = "9",
language = "English",
volume = "5",
pages = "2301--2309",
journal = "International Review of Electrical Engineering",
issn = "1827-6660",
publisher = "Praise Worthy Prize",
number = "5",

}

TY - JOUR

T1 - A novel voltage sag source detection method using TFR technique

AU - Faisa, Mohamed F.

AU - Mohamed, Azah

AU - Shareef, Hussain

PY - 2010/9

Y1 - 2010/9

N2 - Voltage sag is considered as the major power quality disturbance that can disrupt the operation of sensitive equipment. Many power utilities around the world install power quality recorders at strategic sites to monitor the frequency and severity of voltage sags that may affect their customers. The immediate identification of sources of voltage sags is very critical in providing information to customers to resume back their operations. The sources of voltage sags can originate either from upstream or downstream with respect to the monitoring point. This paper presents a novel method to identify the sources of voltage sags using a signal processing technique called the S-transform (ST). An index named S-Transform Disturbance Power (STDP) was developed to identify the origin of the voltage sags. The results of this study showed that the novel method is superior to the other methods in detecting the origin of both symmetrical and asymmetrical voltage sag in actual power systems.

AB - Voltage sag is considered as the major power quality disturbance that can disrupt the operation of sensitive equipment. Many power utilities around the world install power quality recorders at strategic sites to monitor the frequency and severity of voltage sags that may affect their customers. The immediate identification of sources of voltage sags is very critical in providing information to customers to resume back their operations. The sources of voltage sags can originate either from upstream or downstream with respect to the monitoring point. This paper presents a novel method to identify the sources of voltage sags using a signal processing technique called the S-transform (ST). An index named S-Transform Disturbance Power (STDP) was developed to identify the origin of the voltage sags. The results of this study showed that the novel method is superior to the other methods in detecting the origin of both symmetrical and asymmetrical voltage sag in actual power systems.

KW - Power quality

KW - S-transform

KW - Signal processing

KW - Sources of voltage sags

UR - http://www.scopus.com/inward/record.url?scp=79956198801&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79956198801&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:79956198801

VL - 5

SP - 2301

EP - 2309

JO - International Review of Electrical Engineering

JF - International Review of Electrical Engineering

SN - 1827-6660

IS - 5

ER -