A new improved walsh function algorithm for active and reactive power measurement

Garba Aliyu, Saifulnizam Abd Khalid, Jafaru Usman, Ahmad Fuad A Aziz, Hussein Shareef

    Research output: Contribution to journalArticle

    Abstract

    This paper present improved Walsh function (IWF) algorithm as an alternative approach for active and reactive power measurement in linear and nonlinear, balanced and unbalanced sinusoidal three phase load system. It takes advantage of Walsh function unified approach and its intrinsic high level accuracy as a result of coefficient characteristics and energy behaviour representation. The developed algorithm was modeled on the Matlab Simulink software; different types of load, linear and nonlinear were also modeled based on practical voltage and current waveforms and tested with the proposed improved Walsh algorithm. The IEEE standard 1459-2000 which is based on fast Fourier transform FFT approach was used as benchmark for the linear load system while a laboratory experiment using Fluke 435 power quality analyzer PQA which complies with IEC/EN61010-1-2001standards was used to validate the improved algorithm for nonlinear load measurement. The results showed that the algorithm has the potential to effectively measure three phase power components under different load conditions.

    Original languageEnglish
    Pages (from-to)1-8
    Number of pages8
    JournalJurnal Teknologi (Sciences and Engineering)
    Volume67
    Issue number3
    Publication statusPublished - 2014

    Fingerprint

    Reactive power
    Fast Fourier transforms
    Power quality
    Electric potential
    Experiments

    Keywords

    • Fast fourier transform
    • Measurement
    • Nonlinear load
    • Reactive power
    • Walsh function

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Aliyu, G., Khalid, S. A., Usman, J., Aziz, A. F. A., & Shareef, H. (2014). A new improved walsh function algorithm for active and reactive power measurement. Jurnal Teknologi (Sciences and Engineering), 67(3), 1-8.

    A new improved walsh function algorithm for active and reactive power measurement. / Aliyu, Garba; Khalid, Saifulnizam Abd; Usman, Jafaru; Aziz, Ahmad Fuad A; Shareef, Hussein.

    In: Jurnal Teknologi (Sciences and Engineering), Vol. 67, No. 3, 2014, p. 1-8.

    Research output: Contribution to journalArticle

    Aliyu, G, Khalid, SA, Usman, J, Aziz, AFA & Shareef, H 2014, 'A new improved walsh function algorithm for active and reactive power measurement', Jurnal Teknologi (Sciences and Engineering), vol. 67, no. 3, pp. 1-8.
    Aliyu, Garba ; Khalid, Saifulnizam Abd ; Usman, Jafaru ; Aziz, Ahmad Fuad A ; Shareef, Hussein. / A new improved walsh function algorithm for active and reactive power measurement. In: Jurnal Teknologi (Sciences and Engineering). 2014 ; Vol. 67, No. 3. pp. 1-8.
    @article{fb9d3ec05e4d42d29b7304d8df66e11e,
    title = "A new improved walsh function algorithm for active and reactive power measurement",
    abstract = "This paper present improved Walsh function (IWF) algorithm as an alternative approach for active and reactive power measurement in linear and nonlinear, balanced and unbalanced sinusoidal three phase load system. It takes advantage of Walsh function unified approach and its intrinsic high level accuracy as a result of coefficient characteristics and energy behaviour representation. The developed algorithm was modeled on the Matlab Simulink software; different types of load, linear and nonlinear were also modeled based on practical voltage and current waveforms and tested with the proposed improved Walsh algorithm. The IEEE standard 1459-2000 which is based on fast Fourier transform FFT approach was used as benchmark for the linear load system while a laboratory experiment using Fluke 435 power quality analyzer PQA which complies with IEC/EN61010-1-2001standards was used to validate the improved algorithm for nonlinear load measurement. The results showed that the algorithm has the potential to effectively measure three phase power components under different load conditions.",
    keywords = "Fast fourier transform, Measurement, Nonlinear load, Reactive power, Walsh function",
    author = "Garba Aliyu and Khalid, {Saifulnizam Abd} and Jafaru Usman and Aziz, {Ahmad Fuad A} and Hussein Shareef",
    year = "2014",
    language = "English",
    volume = "67",
    pages = "1--8",
    journal = "Jurnal Teknologi",
    issn = "0127-9696",
    publisher = "Penerbit Universiti Teknologi Malaysia",
    number = "3",

    }

    TY - JOUR

    T1 - A new improved walsh function algorithm for active and reactive power measurement

    AU - Aliyu, Garba

    AU - Khalid, Saifulnizam Abd

    AU - Usman, Jafaru

    AU - Aziz, Ahmad Fuad A

    AU - Shareef, Hussein

    PY - 2014

    Y1 - 2014

    N2 - This paper present improved Walsh function (IWF) algorithm as an alternative approach for active and reactive power measurement in linear and nonlinear, balanced and unbalanced sinusoidal three phase load system. It takes advantage of Walsh function unified approach and its intrinsic high level accuracy as a result of coefficient characteristics and energy behaviour representation. The developed algorithm was modeled on the Matlab Simulink software; different types of load, linear and nonlinear were also modeled based on practical voltage and current waveforms and tested with the proposed improved Walsh algorithm. The IEEE standard 1459-2000 which is based on fast Fourier transform FFT approach was used as benchmark for the linear load system while a laboratory experiment using Fluke 435 power quality analyzer PQA which complies with IEC/EN61010-1-2001standards was used to validate the improved algorithm for nonlinear load measurement. The results showed that the algorithm has the potential to effectively measure three phase power components under different load conditions.

    AB - This paper present improved Walsh function (IWF) algorithm as an alternative approach for active and reactive power measurement in linear and nonlinear, balanced and unbalanced sinusoidal three phase load system. It takes advantage of Walsh function unified approach and its intrinsic high level accuracy as a result of coefficient characteristics and energy behaviour representation. The developed algorithm was modeled on the Matlab Simulink software; different types of load, linear and nonlinear were also modeled based on practical voltage and current waveforms and tested with the proposed improved Walsh algorithm. The IEEE standard 1459-2000 which is based on fast Fourier transform FFT approach was used as benchmark for the linear load system while a laboratory experiment using Fluke 435 power quality analyzer PQA which complies with IEC/EN61010-1-2001standards was used to validate the improved algorithm for nonlinear load measurement. The results showed that the algorithm has the potential to effectively measure three phase power components under different load conditions.

    KW - Fast fourier transform

    KW - Measurement

    KW - Nonlinear load

    KW - Reactive power

    KW - Walsh function

    UR - http://www.scopus.com/inward/record.url?scp=84896923436&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84896923436&partnerID=8YFLogxK

    M3 - Article

    VL - 67

    SP - 1

    EP - 8

    JO - Jurnal Teknologi

    JF - Jurnal Teknologi

    SN - 0127-9696

    IS - 3

    ER -